Lead wire length symbols: 0.5 m Nil (Example) A73C 3 m L (Example) A73CL 5 m Z (Example) A73CZ None N (Example) A73CN D-P5DWL is available in sizes 40 to 63. In addition to the models in the above table, there are some other auto switches that are applicable.

Lead wire length symbols: 0.5 m Nil (Example) A73C 3 m L A73CL 5 m Z A73CZ None. N A73CN In addition to the models in the above table, there are some other auto switches that are applicable. For more information, please refer to page 7-5-11. D-P5DWL type: 40 and 50 only available. Made to Order Specifications Please contact SMC.

Lead wire length symbols: 0.5 m Nil (Example) A73C 3 m L (Example) A73CL 5 m Z (Example) A73CZ None N (Example) A73CN Since there are other applicable auto switches than listed, refer to page 8-15-56 for details.

Lead wire length symbols: 0.5 mNil 3 m L 5 m Z None N (Example) A73C (Example) A73CL (Example) A73CZ (Example) A73CN Since there are other applicable auto switches than listed, refer to Best Pneumatics Vol. 7 for details.

D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-A9/A9V D-F7/F7V/J79/J79C/F7W/J79W/F7WV D-F7BA/F7BAV/F79F/F7NT D-A7/A80/A7H/A80H/A73C/A80C/A79W D-P3DWA Applicable auto switch Bore size [mm] 12 to 50 16, 20 32 to 50 32 to 50 Auto switch mounting bracket part no.

Auto Switch Specifications Connector PLC: Programmable Logic Controller D-A73C (With indicator light) D-A73C Auto switch model Applicable load Relay, PLC Load voltage 24 VDC (5) Load current range (4) 5 to 40 mA Circuit diagram e Contact protection circuit None Internal voltage drop 2.4 V or less Indicator light Red LED illuminates when turned ON.

(between lead wire & case) 1500VAC for 1 min.Note 1) (between lead wire & case) Withstand voltage Ambient temperature 10 to 60C IEC529 standard IP67, JISC0920 watertight construction Note 2) Enclosure Note 1) Electrical entry: Connector type (A73C, A80C, C73C, C80C) and D-9, 9A , A9, A9V are 1000VAC for 1 min.

PS 40 NRB75-045 40 CY2S40-PS Note: Pre-wired Switches with 3/4 Pin Connectors available ACCESSORIES SERIES NCY2 A U T O S W I T C H E S Model Type Load Voltage Max Load Current and Load Current Range (mA) D-A72, D-A72H Reed 200VAC 5 ~10 mA D-A73, D-A73H Reed 24VDC 5 ~ 40 mA 100VAC 5 ~ 20mA D-A76H Reed 4 ~ 8 VDC 20mA D-A80, D-A80H 24VAC/DC or less 50mA Reed 48AC/DC 40mA 100VAC/DC 20mA D-A73C

voltage Rail mounting Special function Style Electrical entry Wiring (Output) Indicator 32, 40 12 to 40 Applicable load 0.5 () 3 (L) 5 (Z) (N) AC DC Perpendicular In-line Perpendicular In-line 3 wire (Equivalent to NPN) A96V A96 A76H 5V IC A72H A72 200V Yes Grommet Reed switch Solid state switch A73 A73H 100V 12V A93V A93 Relay PLC 2 wire A90V A90 A80 A80H IC 100V 5V, 12V No 24V A73C

Type Special function Electrical entry Wiring (Output) 0.5 (Nil) 3 (L) 5 (Z) None (N) DC AC connector Perpendicular In-line Perpendicular In-line 3-wire (NPN equivalent) 5 V IC circuit A76H A96V A96 Grommet Reed switch Solid state switch A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 200 V A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F A72 A73 A73C

(between case and cable) Withstand voltage Ambient temperature 10 to 60C IEC529 standard IP67, JISC0920 Protective structure 1) Electrical entry---Connector type (A73C, A80C, R73C, R80C) and D-9, 9lA, A9, A9lV: 1000V AC for 1 min.

Model Type Operating Voltage Maximum Current D-A73 200VAC 5 ~ 10mA Slide Unit Shock Absorber/Cap Type D-A73H Reed 24VDC 5 ~ 40mA NCX2N10 D-E73A 100VAC 5 ~ 20mA NRB031-025/NRBC031-025 NCDBX2N10 D-A80 24VAC/DC or less 50mA NCDPX2N10 D-A80H Reed 48VAC/DC or less 40mA NCX2N15 D-E80A 100VAC/DC or less 20mA NRB031-025/NRBC031-025 NCDBX2N15 D-A76H Reed 4 ~ 8 VDC 20mA NCDPX2N15 D-E76A NCX2N25 D-A73C

PLC D-A76H D-E76A lC Citcuil D-A73C PLC D-A80C PLC 1.2 ms Solid State l\rodd Nurnbef D-F79 lC Circuit, Reay, PLC D-F7P D-J79 D-F/NV lC Circuit, Relay.

Auto Switches Common Specifications Note 1) Electrical entry: Connector type (A73C/A80C/C73C/C80C) and D-9/9A/A9/A9V type: 1000 VAC/min. (Between lead wire and the case) The following switches, Terminal conduit type (D-A3/A3A/A3C/G39/G39A/G39C/K39/K39A/K39C), DIN terminal type (D-A44/A44A/A44C) and Heat resistant auto switch (D-F7NJL) meet the IEC529 standard.

B A (mm) Applicable auto switch D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-F7W/J79W D-F7WV D-F7BAL/F7BAVL D-F79F Other than the models listed in How to Order, the following auto switches are applicable. For detailed specifications, refer to page 1314.

D-A80C D-J79C D-F9BAL D-P5DWL D-P5DWSC Model U 43.5 C(L)KQ 41 42 48 44.5 47.5 36.5 38.5 36 50 Rail mounting type Applicable auto switch: D-A79W D-A7 D-A80 D-A7H D-A80H D-A73C D-A80C D-F7WV D-F7BAL D-F7BAVL D-F7W D-J79W D-F7NTL D-F79F D-F7V D-J79C D-F7 D-J79 [For CLKQ] [For CKQ] B A B A U U Direct mounting type Applicable auto switch: D-A9 D-A9V D-F9WV D-F9BAL D-M9V

PLC D-A76H D-E76A lC Citcuil D-A73C PLC D-A80C PLC 1.2 ms Solid State l\rodd Nurnbef D-F79 lC Circuit, Reay, PLC D-F7P D-J79 D-F/NV lC Circuit, Relay.

The detection position can be changed under the conditions described in step e. : 2. 3. 4. 5. 350 Rotary Cylinder With Auto Switch Series MRQ Auto Switch Mounting Dimensions Reed switch D-A7/A80 D-A7H D-A73C/A80C CRB2 (In parentheses) are the dimensions of A72.

Applicable model: D-A73, A73H, A73C, A93, A93V, A53, A54, B53, B54, C73, C73C, E73A, Z73, D-R73, R73C, 97, 93A, A33, A34, A33A, A34A, A44, A44A 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed. 1. Keep wiring as short as possible.