For detailed specifications, please contact SMC. 100 V Relay, PLC Yes 100 V, 200 V 12 V 24 V (B54) B54 B73C 2-wire 12 V C73C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA H7NF PLC Grommet (B59W) G79 Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V K79 Grommet 2-wire 12 V K79C Connector Relay, PLC Yes 24 V 3-wire (NPN) 3-wire (PNP) IC circuit
Plug-in connector assembly D-A7OC, ASOC D-J79C D-C73C, C80C D.H7C With the convexport ofthe connector uppermost, insert the connector into the auto switch up to the sleeve. Screw the locking ring on to the switch. (Do not tighten with pliers.)
Lead wire length 0.5 m Nil (Example) C73C 3 m L (Example) C73CL 5 m Z (Example) C73CZ None N (Example) C73CN In addition to the models in the above table, there are some other auto switches that are applicable.
Plug-in connector assembly D-A7OC, ASOC D-J79C D-C73C, C80C D.H7C With the convexport ofthe connector uppermost, insert the connector into the auto switch up to the sleeve. Screw the locking ring on to the switch. (Do not tighten with pliers.)
Connector PLC: Programmable Logic Controller Auto Switch Specifications D-C73C (With indicator light) D-C73C Auto switch model Applicable load Relay, PLC 24 VDC (5) Load voltage Load current range (4) 5 to 40 mA Circuit diagram e Contact protection circuit None Internal voltage drop 2.4 V or less Indicator light Red LED illuminates when turned ON.
Lead wire length symbols: 0.5 m Nil (Example) C73C 3 m L (Example) C73CL 5 m Z (Example) C73CZ None N (Example) C73CN Since there are other applicable auto switches than listed, refer to page 8-22-17 for details. For details about auto switches with pre-wire connector, refer to page 8-30-52.
For detailed specifications, please contact SMC. 100 V Relay, PLC Yes 100 V, 200 V 12 V 24 V (B54) B54 B73C 2-wire 12 V C73C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA H7NF PLC Grommet (B59W) G79 Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V K79 Grommet 2-wire 12 V K79C Connector Relay, PLC Yes 24 V 3-wire (NPN) 3-wire (PNP) IC circuit
Auto switch model Electrical entry direction In-line C76 C73 B53 B54 B64 C80 C73C C80C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA G5NT H7NF Load voltage Lead wire* (m) 0.5 () Indicator Wiring (Output) Electrical entry Applicable load Style Special function 3 (L) 5 (Z) (N) AC DC Prependicular B76 B73 5V IC 3 wire(Equiv.
Nil (Example) C73C 5m . Z (Example) C73CZ 3m . L C73CL None .
Load voltage Auto switch model Lead wire length (m)* Indicator Wiring (Output) Electrical entry Applicable load Direction of switch mounting screw In-line C76 C73 B53 B54 B64 C80 C73C C80C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA G5NT H7NF Style Special function 0.5 () (L) (Z) (N) None 3 5 AC DC Perp. B76 B73 I.C. 5V P P P P P P P P P P P P P P P P P 3 wire (Equiv.
Applicable model: D-A73, A73H, A73C, A93, A93V, A53, A54, B53, B54, C73, C73C, E73A, Z73, D-R73, R73C, 97, 93A, A33, A34, A33A, A34A, A44, A44A 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed. 1. Keep wiring as short as possible.
Lead wire length (m) Load voltage Auto switch model Indicator light Special function Type Electrical entry Pre-wire connector Wiring (Output) Applicable load Rail mounting Band mounting 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC Perpendicular In-line 3-wire (NPN equivalent) 5 V IC circuit C76 A76H Reed switch Solid state switch Grommet 200 V 100 V 12 V 12 V C73 C73C H7A1 H7A2 H7B H7C H7NW
Lead wire length symbols: 0.5 m Nil (Example) C73C 3 m L (Example) C73CL 5 m Z (Example) C73CZ None N (Example) C73CN In addition to the models in the above table, there are some other auto switches that are applicable.
Lead wire length (m) Load voltage Auto switch model Indicator light Special function Type Electrical entry Pre-wire connector Wiring (Output) Applicable load Rail mounting Band mounting 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC Perpendicular In-line 3-wire (NPN equivalent) 5 V IC circuit C76 A76H Reed switch Solid state switch Grommet 200 V 100 V 12 V 12 V C73 C73C H7A1 H7A2 H7B H7C H7NW
Lead wire length symbols: 0.5 m Nil (Example) C73C 3 m L (Example) C73CL 5 m Z (Example) C73CZ None N (Example) C73CN In addition to the models in the above table, there are some other auto switches that are applicable.
Contact Protection Box: CD-P11, CD-P12 Auto Switch Hysteresis
4 Wire (NPN) Yes/3 Wire (NPN) Yes/3 Wire (PNP) Yes/2 Wire Yes/4 Wire (NPN) Yes/4 Wire (NPN) Yes/2 Wire No/3 Wire (NPN) Yes/2 Wire D-G59 D-G5P D-K59 D-5NTL D-H7A1 D-H7A2 D-H7B D-H7C D-G59W D-G5PW D-K59W D-G59F D-G79 D-H7PW D-H7BAL D-H7LF D-H7NF D-G5BAL D-H7PW D-H7BW 24VDC 110VAC 220VAC 24VDC 24VDC 110VAC 220VAC 24VDC 110VAC Yes/2 Wire D-B54 Yes/2 Wire D-B53 No/2 Wire D-B64 D-B73 D-C73 D-C73C
Applicable models: D-A73/A73H/A73C/C73/C73C/E73A/Z73/R73 D-97/93A/A93/A93V D-A33/A34/A33A/A34A/A44/A44A D-A53/A54/B53/B54 2) However, when using a two color indication auto switch, the switch (D-A79W/A59W/B59W), be aware that the switch will constantly remain ON if the connections are reversed.
Applicable models: D-A73/A73H/A73C/C73/C73C/E73A/Z73/R73 D-97/93A/A93/A93V D-A33/A34/A33A/A34A/A44/A44A D-A53/A54/B53/B54 2) However, when using a two color indication auto switch, the switch (D-A79W/A59W/B59W), be aware that the switch will constantly remain ON if the connections are reversed.
4 Wire (NPN) Yes/3 Wire (NPN) Yes/3 Wire (PNP) Yes/2 Wire Yes/4 Wire (NPN) Yes/4 Wire (NPN) Yes/2 Wire No/3 Wire (NPN) Yes/2 Wire D-G59 D-G5P D-K59 D-5NTL D-H7A1 D-H7A2 D-H7B D-H7C D-G59W D-G5PW D-K59W D-G59F D-G79 D-H7PW D-H7BAL D-H7LF D-H7NF D-G5BAL D-H7PW D-H7BW 24VDC 110VAC 220VAC 24VDC 24VDC 110VAC 220VAC 24VDC 110VAC Yes/2 Wire D-B54 Yes/2 Wire D-B53 No/2 Wire D-B64 D-B73 D-C73 D-C73C