Flow rate ( /min (ANR)) Relief flow rate ( /min (ANR)) Supply pressure P1 (MPa) VY1 IR2020-02 IR2020-02 IR2020-02 Supply pressure 1.0 MPa Back pressure: 1.0 MPa 1.0 G 0.8 0.204 0.9 0.7 Set pressure P2 (MPa) 0.8 PPA Set pressure (MPa) Set pressure (MPa) 0.6 0.202 0.7 Set point 0.5 AL 0.6 0.200 0.5 0.4 0.4 0.3 0.3 0.198 0.2 0.2 0.1 0.1 0.196 0 200 400 600 800 0 200 400 600 800 1000 1200 1400
160 105 40 53 40 45 75 60 605 610 670 735 835 1000 55 + 0.2 S 2350 2650 2900 310 130 65 120 65 80 170 115 1100 1100 1100 1200 1400 1750 166 + 0.5 S 3450 4300 4700 560 200 110 140 110 130 220 180 1750 1750 1750 1950 2400 2750 240 + 0.5 S Option Specifications Stroke Adjustment Range of Adjuster Option (Identical for extension and retraction ends) Optional wide adjustment range adjuster
) 204 (215) 119 (124) 18 (28) 130 (164) 76 (84) 160 (198) 53 (59) 0.040 0.073 80 1400 750 750 750 25 116 112 102 112 31.5 110 13.5 13.5 140 45 61 129 204 4.5 44 16 27 247 48 28 235 255 192 194 65 76 45 20 34 20 205 CY 1000 (1001 to 1500) 215 (227) 133 (140) 18 (29) 150 (180) 92 (100) 180 (220) 54 (60) 0.040 0.073 100 1500 750 750 750 25 133 136 116 136 35.5 130 13.5 13.5 162 50 64 135 212
Cooling Capacity HEC002 HEC006 Circulating fluid: Clear water Circulating fluid: Clear water 800 1400 700 1200 Ambient temperature: 59 (15C) 600 1000 Cooling capacity (W) Cooling capacity (W) Ambient temperature: 59F (15C) 500 HRG HRS HRZ HRZD HRW HEC HEB HED Technical Data Related Products 800 Ambient temperature: 68F (20C) 400 600 Ambient temperature: 77F (25C) 300 Ambient temperature:
MRQ Mass Rotating angle Size Basic mass (g) Flange (g) Add'l stroke mass (g/mm) 80 to 100 1400 500 4 32 170 to 190 1500 80 to 100 2100 40 500 5 2300 170 to 190 Calculation: (Example) MRQBS32-50CA Basic mass 1400 g 4 x 50 = 200 g Stroke additional mass Total 1600 g For the mass of auto switch alone, refer to pages 767 to 809.
RoHS Thermo-chiller Basic Type HRSE Series How to Order Single-phase 100 VAC HRSE A 018 10 Option Cooling capacity 012 Cooling capacity 1000/1200 W (50/60 Hz) 018 Cooling capacity 1400/1600 W (50/60 Hz) Symbol Option Nil None T High pressure pump mounted Note) Cooling method Note) The cooling capacity will decrease by about 100 W from the value in the catalog.
0.6 0.5 0.8 0.7 0.9 1000 1.0 Flow rate (l /min (ANR)) Relief flow rate (l /min (ANR)) Supply pressure P1 (MPa) IR2120-02 IR2120-02 IR2120-02 Supply pressure: 1.0 MPa Back pressure: 1.0 MPa 1.0 0.8 0.204 0.9 Set pressure P2 (MPa) Set pressure (MPa) 0.7 Set pressure (MPa) 0.8 0.6 0.202 0.7 Set point 0.5 0.6 0.200 0.5 0.4 0.4 0.3 0.3 0.198 0.2 0.2 0.1 0.1 0.196 0 200 400 600 800 1000 1200 1400
288 330 371 412 412 IN 161 241 322 402 482 563 643 724 804 804 OUT 32 12 138 207 276 346 415 484 553 622 691 691 IN 252 378 504 630 756 882 1010 1130 1260 1260 OUT 40 16 212 318 424 530 636 742 848 954 1060 1060 IN 392 588 784 980 1180 1370 1570 1760 1960 1960 OUT 50 20 330 495 660 825 990 1160 1320 1490 1650 1650 IN 624 936 1250 1560 1870 2180 2500 2810 3120 3120 OUT 63 20 560 840 1120 1400
161 241 322 482 563 643 724 402 804 OUT 32 12 691 138 207 276 415 484 553 622 346 691 IN 1260 252 378 504 756 882 1010 1130 630 1260 OUT 40 16 1060 212 318 424 636 742 848 954 530 1060 IN 1960 392 588 784 1180 1370 1570 1760 980 1960 OUT 50 20 1650 330 495 660 990 1160 1320 1490 825 1650 IN 3120 624 936 1250 1870 2180 2500 2810 1560 3120 OUT 63 20 2800 560 840 1120 1680 1960 2240 2520 1400
Output pulse set value [pulses/rev] For instance, set "5600" to Parameter No.PA15, the actually output A/B-phase pulses are as indicated below. 5600 A B-phase output pulses 1400[pulse] 4 (2) For output division ratio setting Set " 1 " in parameter No.PC19. The number of pulses per servo motor revolution is divided by the set value.
Output pulse set value [pulses/rev] For instance, set "5600" to Parameter No.PA15, the actually output A/B-phase pulses are as indicated below. 5600 A B-phase output pulses 1400[pulse] 4 (2) For output division ratio setting Set " 1 " in parameter No.PC19. The number of pulses per servo motor revolution is divided by the set value.
ISE700x03E80x15F4 (10005620) 1023 0x03FF 0 R/W H_2 (OUT2 ) U16 1200 Y OUT2 ISE710x03E80x1556 (10005562) ISE700x02440x1450 (5805200) OUT2 OUT2 ( ) 1024 0x0400 0 R/W P2L(n2L) () U16 2200 Y ISE710x02E20x1450 (7385200) ISE700x02440x1450 (5805200) OUT2 ( ) 1025 0x0401 0 R/W P2H(n2H) () U16 3400 Y ISE710x02E20x1450 (7385200) ISE700x03E80x0CEE (10003310) OUT2 ( ) 1026 0x0402 0 R/W WH2 () U16 1400
ISE76G0x03200x1450 (8005200) ISE77G0x03200x1450 (8005200) ISE78G0x03200x1450 (8005200) ISE70G0x02440x1450 (5805200) ISE75G0x03160x1450 (7905200) OUT2 ( ) P2H(n2H) () U16 3400 Y ISE76G0x03200x1450 (8005200) 1025 0x0401 0 R/W ISE77G0x03200x1450 (8005200) ISE78G0x03200x1450 (8005200) ISE70G0x03E80x0CEE (10003310) OUT2 ISE75G0x03E80x0C85 (10003205) OUT2 ( ) 1026 0x0402 0 R/W WH2 () U16 1400
window comparator) 1024 0x0400 0 R/W U16 2200 Y (8005200) P2H(n2H) (Upper limit of window comparator) Setting range ISE79S0x03200x1450 Setting of OUT2 output set value (upper limit of window comparator) 1025 0x0401 0 R/W U16 3400 Y (8005200) WH2 (Window comparator hysteresis) Setting range ISE79S0x03E80x0C80 Setting of OUT2 hysteresis (window comparator hysteresis) 1026 0x0402 0 R/W U16 1400
Auto switches are included, (but not assembled). 1 Rotary Clamp Cylinder: Standard Series MK Specifications 63 12 16 20 25 32 40 50 Bore size (mm) Double acting 90 10 Clockwise, Counterclockwise Action Rotation angle Note 1) Rotary direction Note 2) Rotary stroke (mm) Clamp stroke (mm) Theoretical clamp force (N) Note 3) 7.5 9.5 15 19 10, 20 20, 50 1400 525 825 40 75 100 185 300 Air 1.5 MPa
Stroke Table Long strokes (mm) Max. manufacturable stroke (mm) Bore size (mm) Standard strokes (mm) Note 1) Lock Unlock 20 25, 50, 75, 100, 125, 150, 200 201 to 350 25 301 to 400 32 301 to 450 25, 50, 75, 100, 125, 150, 200, 250, 300 40 1500 301 to 800 50, 63 301 to 1200 80 301 to 1400 Locked condition Unlocked condition 100 301 to 1500 Note 1) Intermediate strokes other than the above are
71) 424 (95) 530 (119) 636 (143) IN (1060) 1.70 588 (132) 784 (176) 980 (220) 1180 (265) OUT (1960) 3.14 Reed switch D-B53, B54, B64, B59W 20 50 BA-32 BA-04 BA-05 BA-06 495 (111) 660 (148) 825 (185) 990 (223) IN (1650) 2.64 Solid state switch D-G5NTL 934 (210) 1250 (281) 1560 (350) 1870 (420) OUT (3120) 4.99 Reed switch D-A33, A34, A44 20 63 BD1-04M BD1-05M BD1-06M 840 (189) 1120 (252) 1400
Bore stroke 32 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500 700 40 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500 800 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600 1200 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600 1200 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600, 700, 800 1400 100 25, 50, 80, 100, 125, 160, 200,
Based on condition y; IDFS11E is selected as the model to process an air flow larger than 1400 l/min (ANR) with a 60Hz power supply, according to data D-2. 4 4 Note) l/min (ANR) is for reference conditions of 20 C, 1 ATM and 65% relative humidity.
1000 105 40 45 160 55 + 0.2S 65 120 115 170 1100 1100 1100 1200 1400 2350 2650 2900 1750 130 65 80 310 166 + 0.5S 110 140 180 220 1750 1750 1750 1950 2400 3450 4300 4700 2750 200 110 130 560 240 + 0.5S Option Specifications Stroke Adjustment Range of Adjuster Options (Identical for extension and retraction ends) Type Stroke adjustment range Optional wide adjustment range adjusters are