(P.1088) 1) Maximum operating pressure 2400 psig (16.5 MPa) for connection size 3/4 inch. 2) -10 to 90 C for Polyimide seat. 3) Figure of 1/2 inch connection. 4) Tested with Helium gas inlet pressure 500 psig (3.5 MPa). 5) Weight, including individual boxed weight, may vary depending on connections or options.
Thermo-chiller/ Rack Mount Type HRR Series How to Order Option U Air-cooled Refrigeration HRR A 20 012 (UL Standards) Cooling capacity Option 012 1000/1200 W (50/60 Hz) 018 1600/1800 W (50/60 Hz) 024 2000/2400 W (50/60 Hz) 030 2500/3000 W (50/60 Hz) Nil None DM With electric conductivity control function, Applicable to DI water piping M Applicable to DI water piping T High-pressure pump mounted
Vertical Drive Graph (1)-2 Vertical Drive Supply Pressure 0.5 MPa 1000 Operating conditions Vertical drive Graph (1)-2 Load mass M = 5 kg Stroke St = 800 mm Time for stroke required To = 0.5 s 500 RHC100 196J RHC80 127J 100 RHC63 84J RHC50 47J Estimate of the maximum speed Load mass M (kg) 50 RHC40 33J Average stroke speed Vm = St/To = 1600 mm/s Maximum speed Vmax = 1.5 Vm = 2400 mm/s RHC32
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 400 (4"), Stroke A: 2400 (24"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 2400 (24"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)
lbs 5/8 1 1 3/8 1 3/4 2 2 1/2 3 3 1/2 400 37 83 134 186 In applications where extra column strength is required, or for long push stroke 700 30 68 118 168 202 275 cylinders, oversized piston rods may be required. 1000 27 60 105 155 190 257 330 1400 24 53 92 142 174 244 308 385 1800 23 48 82 127 160 230 296 366 It must be noted, however, that oversized piston rods transmit more side load 2400
H5 Initial power / 100 VAC 200/40 400/70 400/80 600/130 800/180 Power 200 VAC 800/40 1600/80 1600/80 2400/130 3200/180 consumption (W) Note 1) Initial power and power consumption are nominal values. Note 2) Heaters are not available for size 16.
(P.1088) 1) Maximum operating pressure 2400 psig (16.5 MPa) for connection size 3/4 inch. 2) -10 to 90 C for Polyimide seat. 3) Figure of 1/2 inch connection. 4) Tested with Helium gas inlet pressure 500 psig (3.5 MPa). 5) Weight, including individual boxed weight, may vary depending on connections or options.
secondary remelt Pneumatically actuated normally closed High pressure type: 20.7 MPa and 9 MPa Designed for bulk specialty gas (BSGS) delivery LOTO option available as an option How to Order (Inlet) (Outlet) AP31 30 2PW MV8 MV8 S Option Model Code Maximum operating pressure 1300 psig (9.0 MPa) 3000 psig (20.7 MPa) 1) Cv 1.0 0.7 Code Specification Indicator switch 4) 13 30 No code IS 1) 2400
High inlet pressure Changes from the standard type are: 30 0.21 AP1210 AP1215 Option Other Parameters Vacuum to 3000 psig (20.7 MPa) ) 4500 psig (31 MPa) 9000 psig (62 MPa) HR Source pressure 20 0.14 Proof pressure (Inlet) Burst pressure 10 0.07 ) 3/4 inch face seal fittings rated to 2400 psig (16.5 MPa) maximum.
80 600/130 800/180 200 V 800/40 1600/80 1600/80 2400/130 3200/180 * The inrush current of the heater flows for several tens of seconds when using 100 V, while it flows for several seconds when using 200 V.
Heater assembly quantity 200/40 200/50 400/100 600/150 800/220 1200/350 100V H4 100C Heater assembly quantity used Heater power W (Nominal value) In-rush/Power consumption (Option symbolOperating voltage) 800/40 800/50 1600/100 2400/150 3200/220 4800/350 200V 1 pc. 1 pc. 1 pc. 1 pc. 2 pcs. 3 pcs. 4 pcs.
lbs 5/8 1 1 3/8 1 3/4 2 2 1/2 3 3 1/2 400 37 83 134 186 In applications where extra column strength is required, or for long push stroke 700 30 68 118 168 202 275 cylinders, oversized piston rods may be required. 1000 27 60 105 155 190 257 330 1400 24 53 92 142 174 244 308 385 1800 23 48 82 127 160 230 296 366 It must be noted, however, that oversized piston rods transmit more side load 2400
mm/s RHC32 21J CC RHC25 12J RHC20 7J 100 RB Model selection by graph 50 J Load weight M = 50 N Max. speed Vmax = 2400 mm/s DGraph 1-2 -X 10 RHC32 2050 100 500 1000 2000 3000 Maximum speed Vmax (mm/s) Data Maximum Energy Absorption Maximum energy absorption (J) 20 25 32 40 50 63 80 100 Bore size (mm) 7 12 21 33 47 84 127 196 10-6-5 5 High Power Cylinder Series RHC 20, 25, 32, 40, 50, 63,
(Or None in the Case of No Switch), X Option: X130US (Stainless Steel Parts: Piston Rod, Tie Rod, Tie Rod Nut, Cushion Valve Needle)
(Or None in the Case of No Switch), X Option: X130US (Stainless Steel Parts: Piston Rod, Tie Rod, Tie Rod Nut, Cushion Valve Needle)
(Or None in the Case of No Switch), X Option: X130US (Stainless Steel Parts: Piston Rod, Tie Rod, Tie Rod Nut, Cushion Valve Needle)
(Or None in the Case of No Switch), X Option: X130US (Stainless Steel Parts: Piston Rod, Tie Rod, Tie Rod Nut, Cushion Valve Needle)
(Or None in the Case of No Switch), X Option: X130US (Stainless Steel Parts: Piston Rod, Tie Rod, Tie Rod Nut, Cushion Valve Needle)
(Or None in the Case of No Switch), X Option: X130US (Stainless Steel Parts: Piston Rod, Tie Rod, Tie Rod Nut, Cushion Valve Needle)
(Or None in the Case of No Switch), X Option: X130US (Stainless Steel Parts: Piston Rod, Tie Rod, Tie Rod Nut, Cushion Valve Needle)