A76H A96V A96 IC 5V A72 A73 A72H A73H 200V Yes Yes No No Yes Yes Grommet Reed switch 12V 100V A93V A90V A93 A90 Option Part No.

None Contact protection circuit D-A93 2.4V or less (to 20mA)/3V or less (to 40mA) D-A93V 2.7V or less Internal voltage drop 0.8V or less Indicator light Red LED lights when ON Lead wire D-A90(V), D-A93(V) Oil proof heavy duty vinyl cable, 2.7, 0.18mm2 x 2 cores (brown, blue), 0.5m D-A96(V) Oil proof heavy duty vinyl cable, 2.7, 0.15mm2 x 3 cores (brown, black, blue), 0.5m Note 1) Refer to

Cylinder stroke (mm) Bore size (mm) 25 50 100 75 125 150 175 300 200 500 250 400 0.29 0.33 0.4 0.36 0.43 0.47 12 0.51 0.58 0.72 0.65 0.79 0.86 0.93 1.0 20 0.94 1.15 1.05 1.26 1.36 1.47 1.58 1.79 32 2.0 1.7 1.83 1.95 2.08 2.2 3.7 2.45 3.2 40 2.7 3.4 5.5 50 4.1 4.2 6.6 63 5.0 Rod End Nut Dimensions (1 piece is included as standard.)

) A93 3mL A93L PLC: Programmable Logic Controller Refer to applicable auto switch list Page 182.

Weight/( ): Denotes the values with D-A93. (g) Bore size (mm) Hexagon socket head cap screw dia.

For D-A93, only outward electrical entry (D dimension) is available. Dimensions in parentheses apply to 12-CXSJ10.

NPN) Piping IC 5V A76H A96V A96 200V A72H A72 Screw-in piping With One-touch fitting (2) F Yes Yes No No Yes Yes Grommet A73H A73 Reed switch 12V 100V A93V A93 Note 2) The tubes for the built-in One-touch fittings are 32 to 63. They cannot be used for the air-hydro.

Mounting of auto switch Auto switch mounting screw (M2.5 x 0.45 x 8L) Tightening Torque of Auto Switch Mounting Screw [Nm] Auto switch Auto switch model Tightening torque Auto switch mounting nut D-M9(V) D-M9W(V) D-M9A(V) D-A93 Auto switch mounting screw (M3 x 0.5 x 8L) 0.05 to 0.15 Auto switch D-A9(V) (Excluding D-A93) 0.10 to 0.20 Auto switch fixing screw (M2.5 x 0.45 x 10L) Auto switch

Without auto switch: 10C to 70C With auto switch: 10C to 60C (No freezing) Ambient and fluid temperature Mounting bracket Bore size (mm) 10 16 Foot Flange CJ-L016C CJK-L016C CJ-F016C CJK-F016C Piston speed Stroke length tolerance +1.0 0 50 to 400 mm/s Mounting Grease Cleanliness class (ISO class) Basic/Double-side bossed/Single foot/Double foot/Rod flange/Head flange 10-/11-: Fluorine grease

Piston speed Caution The cylinder speed upper limit that retains the particle generation grade is 400 mm/s. Back matter 5 Clean series: Common Precautions 3 Be sure to read before handling. Refer to the main text for detailed precautions for every series.

Bore Size: 12mm, Stroke: 200mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal

Bore Size: 12mm, Stroke: 150mm, Adjuster: Metal Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 12mm, Stroke: 50mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 12mm, Stroke: 200mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 12mm, Stroke: 150mm, Adjuster: C (Metal Stopper), Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal

Bore Size: 12mm, Stroke: 50mm, Adjuster: Rubber Stopper, Centralized Piping/Switch Rail: Centralized Piping One Side, w/Switch Rail, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal

IC circuit A96 A96V 5 V Yes 24 V Grommet A93V2 A93 A90 100 V Relay, PLC 2-wire 12 V A90V IC circuit No 100 V or less 1 Although it is possible to mount water resistant type auto switches, note that the rotary actuator itself is not of water resistant construction. 2 1 m type lead wire is only applicable to D-A93. Auto switches marked with a are produced upon receipt of orders.

B D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Parallel electrical entry B A A D Reed Switch D-A90(V), D-A93(V), D-A96(V) Reed Switch D-A90(V), D-A93(V), D-A96(V) Set screw (included to auto switch) (mm) Stroke (mm) 20 45 25 51 31 Stroke (mm) 10 34.5 35.5

Please consult with SMC regarding water resistant type with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked with are produced upon receipt of order.

However, if there is any problem, use a 3 wire DC style. 3.8-11 Series CXT Auto Switch Mounting Position and Mounting Height Reed switch Solid state switch A B W D-F9NW D-F9PW D-F9BW D-A90 D-A93 D-A96 D-F9N D-F9P D-F9B D-F9BAL 12 A B W 16, 20, 25 W A B 32, 40 (mm) D-A90 D-A93 D-A96 D-F9NW D-F9PW D-F9BW D-F9N D-F9P D-F9B Auto switch model D-F9BAL Symbol A B W A B W A B W Standard stroke 12