SMC Corporation of America
Elite Part Number Search
Search Results "MXQR6L-40C"

(mm) 2.2 2.5 4 5 6.5 8 MS Black (B) T Max. operating pressure (at 20C) 1.2 MPa Burst pressure VMG Refer to the burst pressure characteristics curve. 12 15 19 27 32 12 Minimum bending radius (mm) Operating temperature 0 to 40C Burst Pressure Characteristics Curve and Operating Pressure Material Conductive nylon + Flame resistant nylon (Equivalent to UL-94 standard V-0) 104 to 107 Surface

1.8 (50) Horizontal: 17.6 (500), Vertical: 3.5 (100) Optical linear encoder (incremental) Sensor 30 None 1.25 Provided 30 None 1.25 Provided 30 None 1.25 Provided Pushing operation 6 1 to 4.8 1 to 5 1 to 3.9 Positioning operation Positioning repeatability (m) Note 4)5) Accuracy (m) Note 4)5) 90 5 90 5 90 5 Measurement Maximum speed (mm/s)Note 6) 100 10 100 10 100 10 400 41 to 104F (5 to 40C

Next, pour water at 5 to 40C, then measure the flow rate with a pressure differential of 0.075 MPa. However, the pressure differential needs to be set with a large enough difference so that the Reynolds number does not go below a range of 4 x 104. By substituting the measurement results for formula (8) to figure out Av.

Cooling capacity None Nil C D N Z Analog communication Symbol 001 002 004 008 Cooling capacity DeviceNet communication 1 kW NPT fittings 2 kW Temperature range setting Circulating fluid automatic recovery 4 kW Temperature range setting 1 kW 2 kW 4 kW 8 kW Symbol L H W 8 kW 20 to 40C 20 to 90C 20 to 90C Specifications (For details, please consult our Product Specifications information.)

ACG20 to 40 AF + ARG + [S] + AL (7) Pressure switch S AF + [S] + ARG ACG20B to 40B ACG20C to 40C AF + AFM + [S] + ARG ACG20 to 40 AF + ARG + AL + [V] Residual pressure relief 3 port valve AW + AL + [V] ACG20A to 40A Port size AF + ARG + [V] V ACG20B to 40B Body size Port size ACG20C to 40C AF + AFM + ARG + [V] Symbol 20 30 40 AW + AFM + [V] ACG20D to 40D 01 02 03 04 1/8 Note 6) When more

FR one-touch fittings: Series KR-W2 Metal one-touch fittings: Series KQB2 Applicable fittings 0.8 MPa At 20C Max. operating pressure 0.65 MPa At 40C How to measure the minimum bending radius 0.5 MPa At 60C Burst pressure Refer to the burst pressure characteristics curve.

Grease Grease-free R Clockwise L Counterclockwise Body material A2017 Weight (g) 12.5 49 114 206 310 * Air purication rating: JIS B 8392-1 (ISO8573-1) Quality Degree 4, 4, 2 or more 2A 3A Low profile cyclone type Outer body diameter (mm) 20 25 Piping port size 1.6 Fluid Air* XT661 X260 2A R Operating pressure 0.01 to 0.5 MPa Proof pressure 0.75 MPa Ambient and operating temperature 5 to 40C

310 150 1401 to 1500 270 130 Max. acceleration/deceleration [mm/s2] 20 (Refer to page 4 for limit according to work load and duty ratio.) o0.02 Positioning repeatability [mm] Note 4) Lead [mm] 16 8 20 10 Impact/Vibration resistance [m/s2] Note 5) 50/20 Actuation type Ball screw Guide type Linear guide Allowable external force 4.5 lbf (20 N) Operating temperature range 41 to 104F (5 to 40C

Next, pour water at 5 to 40C, then measure the flow rate with a pressure difference of 0.075 MPa. However, the pressure difference needs to be set with a large enough difference so that the Reynolds number does not go below a range of 4 x 104 . By substituting the measurement results for formula (8) to figure out Av.

Note) 20 Min. bending radius mm Min. bending radius mm 10 15 27 35 75 60 48 36 24 25 13 20 to 60C, With water: 0 to 40C (with no freezing) 100 20 to 60C, With water: 0 to 40C (with no freezing) Operating temperature Operating temperature Polyurethane Material Material Nylon 12 Note) Best Pneumatics No.4, page 2.4-1 Note) Best Pneumatics No.4, page 2.4-3 20m roll O.D. I.D.

Next, pour water at 5 to 40C, then measure the flow rate with a pressure difference of 0.075 MPa. However, the pressure difference needs to be set with a large enough difference so that the Reynolds number does not go below a range of 4 x 104 . By substituting the measurement results for formula (8) to figure out Av.

Turbine oil P-32 Viscosity according to ISO Grade Classification of viscosity cst (40C) Classification of viscosity cst (40C) 32 32 Kyushu Oil Co. Stork Turbine 32 Nippon Oil Corp. Turbine oil 32/ Mitsubishi turbine 32 Showa Shell Sekiyu K.K. Turbine 32 Cosmo Oil Co., Ltd. Cosmo turbine 32 Tonen General Sekiyu K.K. General R turbine 32 Japan Energy Corp.

Series IDF can accommodate an inlet temperature of 40C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger.

The HAA can cool high temperature compressed air from compressors down to 40C or less while efficiently removing moisture from the air.? The series does not require cooling equipment, and is free from concerns such as water supply cut-off or freezing.?

MHZ2-40C, ACTUATOR, MHZ2 GRIPPER, PARALLEL, M1, 40MM MHZ2, 1.54880 lb

weight Output signal capacity Open drain output (Max.30 VDC or less, Max. 20 mA) Nominal size Basic weight Emergency stop, Output deviation, Power supply deviation, Driving deviation, Temperature deviation Stroke deviation, Motor deviation, Controller deviation Emergency detection items 16 2.24 0.14 0.01 General Specifications 25 3.95 0.21 0.02 How to calculate/Example: E-MY2C25-300TAN 5 to 40C

GXL-8F GXL-8FI GXL-8FB GXL-8FIB GXL-8FU GXL-8FUB N.O (A contact) N.C (B contact) AC servomotor (30w) Motor N.C (B contact) N.O (A contact) Lead screw Positioning repeatability Lead Speed Ball screw 8mm 0.03mm 2mm 50mm/s 10 (4)kg 5 (4)kg N.C (B contact) Refer to page 318 for detailed specifications of proximity switches. 5mm 100mm/s 10 (4)kg 5 (4)kg High rigidity direct acting guide 5 to 40C

Example) LXPBABC-100SB-F9N1F9G1-X12 Brake Home position switch Note 2) Without brake With brake Nil B None Yes (cable length 0.3m) Nil S Specifications Motor AC servomotor (30w) Lead screw Positioning repeatability Ball screw 8mm 0.03mm Lead Speed 2mm 50mm/s 5mm 100mm/s Horizontal Vertical 6kg 5kg 6kg 5kg Ball bushing 5 to 40C (with no condensation) Work load Guide type Operating temperature

Front matter 5 (4) Test method By attaching the equipment for testing with the test circuit shown in Fig. (3) and running water at 5 to 40C, measure the flow rate with a pressure difference of 0.075 MPa. However, the pressure difference needs to be set with a large enough difference so that the Reynolds number does not go below a range of 4 x 104.

Fluid 5 to 40C (41 to 104F) Operating temperature C 0.2M to 1 x 10 -6 {1.5k to 7.5 x 10 -9} Operating pressure Pa {Torr} 5 8 5 8 Conductance l/s 1.3 x 10 -8 {1 x 10 -7} at ordinary temperatures, excluding gas permeation 1.3 x 10 -11 {1 x 10 -10} at ordinary temperatures, excluding gas permeation Internal External Leakage Pa m3/s {Torr l/s} KF16 KF25 KF16 KF25 Flange type/size Principle materials