VX31 DC Note 1) Dew point 10C or less Note 2) 50cSt or less Note 3) "D", "N" in the parenthesis are option symbols.
Max. operating pressure 0.7MPa CNA Min. operating pressure 0.08MPa Without auto switch: 10C to + 70C With auto switch: 10C to + 60C Ambient and fluid temperature (No freezing) CNG 50 to 500mm/s Maximum piston speed: 500mm/s It can be used at 50 to 500mm/s provided that it is within the allowable kinetic energy range.
to 70C (No freezing) Ambient and fluid temperature With auto switch 10C to 60C (No freezing) None Rubber bumper Female thread Rod end thread JIS Class 2 Rod end thread tolerance +1.0 Tolerance of stroke length 0 Through hole/Both ends tapped Mounting Precautions 50 to 500mm/s Operating piston speed Minimum Strokes for Auto Switch Mounting Unit: mm Be sure to read before handling.
Data Maximum Settable Temperature Graph 1: IDH4 Graph 2: IDH6 F 50F (10C) 44.6F (7C) 41F (5C) Pressure dew point 37.4F (3C) 50F (10C) 44.6F (7C) 41F (5C) Pressure dew point 37.4F (3C) Air flow capacity scfm (L/min [ANR]) 17.6 (500) 28.3 (800) Air flow capacity scfm (L/min [ANR]) 15.9 (450) Selection example 24.7 (700) 14.1 (400) 21.2 (600) 12.4 (350) Selection example Selection example 10.6
to 70C With auto switch: 10C to 60C (No freezing) Proof pressure Maximum operating pressure Minimum operating pressure 2 Bore size Suction flow rate l/min (ANR) 20/25/32/40 Ambient and fluid temperature 10-/11-: 30 to 400 mm/s, 21-/22-: 50 to 400 mm/s Piston speed Stroke length tolerance Mounting style +1.4 0 Basic style/Axial foot style/Rod side flange style/Head side flange style 10-/11
Inlet air temperature 40C A 0.82 Inlet air temperature 60C A 0.95 Ambient temperature 35C B 0.96 Ambient temperature 35C B 0.93 Outlet air pressure dew point 10C C 1 Outlet air pressure dew point 10C C 1 Inlet air pressure 0.5 MPa D 0.88 Inlet air pressure 0.5 MPa D 0.88 Air flow rate 0.3 m3/min Air flow rate 0.4 m3/min Power supply frequency 50 Hz Power supply frequency 60 Hz *1
1 50F (10C) 68F (20C) 86F (30C) Standard model Set dew point (Normal operation) Accumulated running hours display Helps maintenance control of the dryer. Gives notice of the maintenance timing etc. 1. Energy saving operation (ECO LED is ON green): Dew point can be set manually between 50 to 86F(10 to 30C). 2. Normal operation (ECO LED is OFF): Dew point is fixed to 50F (10C).
HRZ Series 8.1 Specification 8-3 HRX-OM-I051 Chapter 8 Appendix Specification for ethylene glycol solution (low temperature) Table 8-4 Specification for Ethylene Glycol Aqueous Solution (Low Temperature) Model HRZ001-L1 HRZ002-L1 HRZ004-L1 HRZ008-L1 Cooling method Water cooled refrigerant Cooling capacity*1 (50Hz/60Hz) kW 1.0 (At -10C) 2.0 (At -10C) 4.0 (At -10C) 8.0 (At -10C) Operating
45 17 AC VXP23 DC 4 5 6 7 8 9 Operating Fluid and Ambient Temperature High temperature water (3) Operating fluid temperature (C) Ambient temperature (C ) Steam (3) Temperature conditions Power source Water (Standard) Air (Standard) Oil (Standard) (D, E) High temperature oil (3) (S) (D) 99 100 183 AC DC AC DC 60 40 80 60 60 40 40 60 Maximum Minimum 1 10 5 (2) 10 (1) Note 1) Dew point: 10C
) Circulating fluid system Cooling water system Electrical system 2.0 (at 10C) 1.0 (at 20C) 2.0 (at 20C) 4.0 (at 20C) 8.0 (at 20C) 2.0 (at 20C) 8.0 (at 20C) 4.0 (at 10C) 8.0 (at 10C) 2.8 (at 10C) 3.2 (at 10C) 2.3 (at 20C) 2.6 (at 20C) 2.8 (at 20C) 3.0 (at 20C) 2.3 (at 20C) 3.3 (at 20C) 3.6 (at 10C) 5.9 (at 10C) Cooling capacity Note 3) (kW) Heating capacity Note 3) (kW) Temp. stability Note
/Japanese 1 pc.), Y-strainer 20A 1 pc., Barrel nipple 20A 1 pc., Drain pan for the pump Weight (dry state) kg 151 154 Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 10C or less.
(including 6 M8 bolts) Note 10) Weight (dry state) kg Approx. 150 Approx. 180 Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 10C or less. Note 2) Use fluid in condition below as the circulating fluid.
to 70C, With auto switch: 10C to 60C (No freezing) Mounting Bracket Part No.
to 70C Ambient and fluid temperature With auto switch: 10C to 60C (No freezing) Auto switch specifications and the proper mounting positions for stroke end detection are the same as those for double acting, single rod type.
25C MHZ2-6C/MHZA2-6C 140 Pressure 0.7 MPa Pressure 0.7 MPa 8 120 0.6 MPa 0.6 MPa Pressure 0.7 MPa Pressure 0.7 MPa Gripping force (N) Gripping force (N) 100 6 0.5 MPa 0.5 MPa 0.6 MPa 0.6 MPa 80 0.4 MPa 0.4 MPa 0.5 MPa 0.5 MPa F 4 60 0.3 MPa 0.3 MPa 40 0.4 MPa 0.4 MPa 2 0.25 MPa 0.25 MPa 20 0.3 MPa 0.3 MPa 0 10 20 30 0 20 40 60 80 100120 Gripping point L (mm) Gripping point L (mm) F MHZ2-10C
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com F MHZ2-10C/MHZL2-10C MHZ2-32C 250 Pressure 0.7 MPa Pressure 0.7 MPa Pressure Internal Grip Pressure 0.7 MPa Pressure 0.7 MPa 20 0.6 MPa 0.6 MPa 200 MHZA2, MHZ2, MHZL2 0.6 MPa 0.6 MPa Gripping force (N) Gripping force (N) 15 0.5 MPa 0.5 MPa 0.5 MPa 0.5
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com F MHZ2-10C/MHZL2-10C MHZ2-32C 250 Pressure 0.7 MPa Pressure 0.7 MPa Pressure Internal Grip Pressure 0.7 MPa Pressure 0.7 MPa 20 0.6 MPa 0.6 MPa 200 MHZA2, MHZ2, MHZL2 0.6 MPa 0.6 MPa Gripping force (N) Gripping force (N) 15 0.5 MPa 0.5 MPa 0.5 MPa 0.5
If the set temperature is repeatedly changed by 10C or more, the thermo-con may fail in short periods of time. Model Air flow [m3/min] Heat generation [W] HECR002-A 2 600 HECR004-A 5 1300 HECR006-A 5 1400 HECR008-A 7 1700 HECR010-A 7 2500 HECR008-W 0.2 200 HECR012-W 0.4 250 Operating Environment/Storage Environment Warning Facility Water Caution 1.
Low concentrations, however, can lead to freezing when circulating fluid temperature is 10C or lower and cause the thermo-chiller to break down. 5. A magnet pump or mechanical seal pump is used as the circulating pump for the circulating fluid.
Specifications Suction flow rate of vacuum type (Reference values) Bore size (mm) 6 10/16 Item 1.05MPa 0.7MPa 0.14MPa Proof pressure Max. operating pressure Min. operating pressure Ambient and fluid temperature Piston speed 1 Size Suction flow rate l/min (ANR) 6/10/16 0.08MPa (Air cushion 0.1MPa) Without auto switch : 10C to 70C, With auto switch : 10C to 60C (With no condensation) Stroke