(reed or solid state input) for 30 ms or longer -20No.PF-OMX0007-A NPN + Analogue output type PF3A7##H-ES/FS#-##-# Maximum load current: 80 mA Internal voltage drop 2 V max.
Incorrect wiring MS: Green LED flashes (1) Setting error (2) PLC has stopped operating, (1) Set up configuration configuration correctly. or the communication is idling. (2) Set PLC in RUN status. MS: Red LED flashes Set up the configuration correctly. 5.2 PLC setting (Configuration) Recoverable error (P.39) MS: Red LED is on Unrecoverable error Stop using the product.
-10 ~ 50C / 14 ~122F Ambient & Fluid Temperature 10 5 3 Max Operating 2 Position Single/Double 3 3 3 Frequency / Hz 3 Position Non Locking Push Type Manual Override Push Locking Slotted Type Push Locking Lever Type Common Exhaust for Main & Pilot Pilot Exhaust Free Mounting Position 0.23 0.59 0.87 Cv Factor M O D E L R E S P O N S E T I M E S E R I E S S Y 3 / 5 / 7 0 0 0 Response Time ms
Brown ON 80 mA Max. 24 VDC VS VL OFF White Release output Black ON Timer period Blue 20 to 2,000 ms Note) When power is supplied, release output is performed once for the time period only.
External input does not operate No reaction to the external input The input signal duration is too short Check that the white input wire is connected to GND for 30 ms or more.
(Effective energizing time is over 67 ms at 24 VDC.)
Positioning Operation Pushing Operation ON OFF ON OFF IN IN Input Input 15 ms or more Output the step data no. 15 ms or more Output the step data no.
Wireless System RoHS Usable even in welding environments High-speed connection Noise resistance Communication response Signal response time: 5 ms Uses the 2.4 GHz ISM frequency band Frequency hopping: Every 5 ms From power supply ON to start of communication: Min. 250 ms*1 *1 For wireless slave Communication cables not required Compatible protocol Number of I/O points Reduced wiring work,
Incorrect wiring MS: Green LED flashes (1) Setting error (2) PLC has stopped operating, (1) Set up configuration configuration correctly. or the communication is idling. (2) Set PLC in RUN status. MS: Red LED flashes Set up the configuration correctly. Refer to Hardware Configuration (P.20) for details. Recoverable error MS: Red LED is on Unrecoverable error Stop using the product.
Inappropriate specifications Leave an interval of a minimum of 15 ms (recommendation is 30 ms) between input signals and maintain the state of the signal for a minimum of 15 ms (recommendation is 30 ms), because PLC processing delays and driver scanning delays can occur. 8.4 Response time for the driver input Check the timing of the signal from the PLC to the driver.
Check the state GW unit MS LED Refer to fault of the GW unit. is OFF. No.1. GW unit MS LED Refer to fault is ON red. No.2. GW unit MS LED Refer to fault is flashing red. No. 3. GW unit MS LED is flashing green. Refer to fault No. 4. GW unit NS LED Refer to fault is OFF. No. 5. GW unit NS LED is Refer to fault ON red No. 6. GW unit NS LED is Refer to fault flashing red. No. 7.
Model Position/No. of solenoid Type Port size Max.Operating Response Weight Ibs (NPTF) Cv factor cycle CPM time (ms) (kgf) Plug-in Non Plug-in o 1h! Single NVFR2100 NVFR2110 2 position 0.9 300 20 or less 0.75 (0.34) 114 1h! Double NVFR2200 NVFR2210 0.9 300 20 or less 0.92 (0.42) 14 1h! Closed NVFR2300 NVFR2310 center 0.7 180 30 or less 0.95 (0.43) 1f4 1h!
;200 million cycles VQC21fi): 20 ms 2 ms;2fi) million cycles For r,lf, srunh vQc4loo: 17 ms 3 ms; 100 million cycles P!
PNP + Analog output type PF2M7mm-m-Em-mmm PF2M7mm-m-Fm-mmm Load White OUT2 (PF2M7 -B only) or 0 V 50 ms 50 ms 16 PF2M7(-L) Series Internal Circuits and Wiring Examples PF2M7mm-m-Lm-mmm NPN output type PNP output type Brown DC (+) Brown DC (+) Load U Main circuit Main circuit Main circuit Main circuit Black OUT1 Black OUT1 18 to 30 VDC + + Load Load 18 to 30 VDC U White N.C.
Momentary change Pressure Set value P_1 H_1 t (ms) t (ms) Time
H D MS T T (with seal) VMG Hexagon Socket Head Male Connector: KJS Connection thread (T) UNF NPT <10-32 UNF> <10-32 UNF>
Available response time settings 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms Principle This function averages pressure values measured during the response time set by the user and then compares the average pressure value with the pressure set point value to output the result on the switch.
(Effective energizing time is over 62 ms at 24 VDC.)
Available response time settings 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms
ZSE20CF : 5.0 kPa ISE20CH : 0.100 MPa Delay time Delay time of the switch output can be selected. 1.5 ms or less Display color Selects the output according to the display color. OUT1 ON : Green OUT1 OFF: Red -30No.PS-OMU0009-D [F 2] Setting of OUT2 Page 36 Same setting as [F 1] OUT1.