3 3 3 MHY MHW MRHQ Direct mounting type Misc.

[6 mm or 1/4" (x)] 1.2* 2.1* 2C 1.08 66 3/8 10 mm or 3/8" 2.4 3.0 3C 2.18 133 3/8 10 mm or 3/8" 4.8 5.2 4C 4.34 265 3/8 10 mm or 3/8" 3.2 3.7 5C 8.7 531 3/8 10 mm or 3/8" 7.5 11.0 6C 17.5 1068 3/4 10 mm or 3/8" 12.0 20.0 Air supply piping 10 mm or 3/8" for all actuators.

And it can be used in the vacuum applications. 2 position single/3 position 0.15 to 0.9 MPa Operating pressure range 2 position double VF 0.1 to 0.9 MPa Max. 50C Ambient and fluid temperature 2 position double VFR 45 ms or less Note) 45 ms or less Note) Response time 3 position 60 ms or less Note) 70 ms or less Note) 2 position double VP4 Max. operating frequency 5 Hz 5 Hz Courtesy of Steven

PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE OUT OUT ON: Red ON: Green OUT OUT OUT PRESSURE PRESSURE 2.5 ms 20 ms 160 ms PRESSURE PRESSURE OUT OUT ON/OFF: Red ON/OFF: Green Press the SET button to set the color and proceed to the operating mode setting. If the analog output is set, press the UP or DOWN button and select the desired display color from (Green) or (Red).

MHF Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MHL Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MHR 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MHK 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and

MHF Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MHL Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MHR 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MHK 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and

p 1o 12 stalons Lateral Plug.in Style Manifold series VQCI 000/20044000 r t Fast response times and long service life VQCl100: 10 ms 2 ms; 200 million cycles VQC2100: 20 ms 2 ms; 200 million cycles VQC4100: 17 ms 3 ms; 100 million cycles ( ( I T CE compliment " , t 4-position dual 3-pod valves for independent control of A & B ports Availabe conf igurations IN.C.A.C.], lN.O /N.O l, and [N.c

2 ms; 200 million cycles VQC2100: 20 ms 2 ms; 200 million cycles VQC4100: 17 ms 3 ms; 100 million cycles Compact and large flow Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Connector Flow characteristics Note) Metal seal Applicable cylinder size (mm) Type (Series

Auto switch model Lead wire length (m) Load voltage Wiring (Output) Pre-wired connector Applicable load DC AC Indicator light Electrical entry Type Special function Perpendicular In-line 0.5 (Nil) 1 (M) 3 (L) 5 (Z) 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN equivalent) M9N M9P M9B M9NW M9PW M9BW M9NA1 M9NV M9PV M9BV M9NWV

Start-up speed = PM x 0.9 t MPa/ms 17-3-74 5 The VX series will be revised shortly.

Insufcient supply ow rate Flow rate control Position control (Fully closed) 250 ms 250 ms 2000 ms 1 A

A miniature fitting that can be removed without the use of tools.Features· Barb fitting.· Compact piping space.· Rotates 360° around the stud as an axis, allowing it to be fixed at any angle.Applications· Ideal for tube piping.

Input data only (Default setting) Pin number OFF OFF OFF ON ON ON 2 : : 3 1 4 2 Content Content 100 Mbps, half duplex 100 Mbps, full duplex 10 Mbps, half duplex 10 Mbps, full duplex OFF OFF OFF ON ON ON 3 : : Automatic Signal name Setting2 1 2 3 4 5 6 7 8 ON OFF OFF OFF ON ON ON RX+ RXSettings2 TX+ TX: : OFF OFF OFF ON ON ON : : (2) (3) Content OFF OFF OFF ON ON ON SI unit output data size

PC-98 (MS-DOS) Edition Operating environment Model: LC1-1-S1 PC-9821, PC-98, PC-9801 with 80286 or higher CPU. PC-H98 series and compatible machines (except for high resolution mode) Computer MS-DOS Ver 3.3 or higher 640KB or more 1MB capacity 3.5 inch floppy disk drive OS Memory Disk drive MS-DOS is a registered trade mark of the Microsoft Corporation.

pressure) (EA)(P)(EB) 5 1 3 (EA)(P)(EB) 5 1 3 Pressure center (B) (A) 4 2 (EA)(P)(EB) 5 1 3 Model Model Flow characteristics (1) Response(3) time (ms) Max. (2) 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) Type of actuation Weight(4) (kg) Port size operating cycle (Hz) Plug-in Non plug-in C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv 17 0.36 4.7 18 0.40 5.0 20 0.28 5.2 23 0.32 6.2 23 0.27 5.8 25 0.21

Fittings & Tubing Air Cylinders Rotary Actuators 3(R2) 1 (P) (R1)5 1 (P) (R1)5 3(R2) t e q t r w qr w (B) 2 (A) 4 (B) 2 (A) 4 u u 3 (R) 1 (P) 5 (R) 3 (R) 1 (P) 5 (R) y 3 position closed center/exhaust center/pressure center 3 position closed center 2(B) (A)4 q t r w 3(R2) 1 (P) (R1)5 (B) 2 (A) 4 3 position exhaust center 2(B) (A)4 3(R2) 1 (P) (R1)5 3 position pressure center u 2(B) (A)4 3

(Effective energizing time is over 62 ms at 24 VDC.) 1 () (+) Red (+) 4 Timer circuit Diode LED Coil Coil Varistor 3 (+) () 1 2 Black () 3 1 1: Starting current 2: Holding current With light/surge voltage suppressor (U) 1 () (+) Solenoid valve side pin wiring diagram Coil Varistor Working Principle 3 (+) () 3 5 7 With the above circuit, the current consumption when holding is reduced to save