Product Outline.6 2.1 Product features.6 2.2 How to Order.7 2.3 Product configuration .8 2.4 Start up Procedures .9 (1) Confirmation of the package content .9 (2) Installation.9 (3) Wiring and connection.9 (4) Power ON alarm (error) .10 (5) Operation pattern setting.10 (6) Trial run (actuator adjustment).10 3.
200 million cycles 2 ms VQZ2000 18 ms VQZ3000 21 ms Metal seal, single solenoid with light/surge voltage suppressor, according to SMC life test conditions.
ZK2-OM01301 6. Construction/Replacement Parts 6.1.
VQ1000 10 ms 200 million cycles VQ2000 20 ms Dispersion accuracy 2 ms Innovative mounting methods A valve can be changed without entirely disassembling the manifold.
Size Ejector System Vacuum Pump System Port Metric Inch Metric Inch PV 6 1/4 6 1/4 V 6, 8 1/4, 5/16 6, 8 1/4, 5/16 EXH (Port exhaust) 8 5/16 PE EXH Common Port open to atmosphere Note 1) PS 4 5/32 PD Note 2) M3 M3 : Not applicable Note 1) Piping for PE port is available as an option (M3). Refer to page 12. Note 2) A model with PD port (M3) is available as an potion. Refer to page 12.
Note 6) When the current output is selected.
(0.1 ms) 6.431.6 ms (0.4 ms) 32132.8 ms (1.6 ms) 0.4132.8 ms IO-Link Vendor ID 065535 dec (0) Vendor ID IO-Link Device ID 016777215 dec (0) Device ID 3IO-Link Manual 63 No.EX-OMW0014CN-A Byte Swap Byte Swap 8 8 . 9-11 8 Byte Swap Direct (No swap) 0x0123 4567 89AB CDEF Swap 16 bit 0x2301 6745 AB89 EFCD Swap 32 bit 0x6745 2301 EFCD AB89 Swap All 0xEFCD AB89 6745 2301 2 swap 32bit Byte
(P.23) 6. PWR:(P.25) MS: PLC STOP PLC RUN MS: 4.2 (P.19) MS: NS: IP IP 2 MSNS / PLC PLC NS: PLC PLC NS: NS: IP IP 15.(P.62) 3 ALM -79- USB PC USB USB USB LEC-W2 PC COM COM COM PC COM COM COM LEC-W2 4 (LEC W2) (JXC)= = =USB = (JXC) OFF (JXC) (PLC )( ) ONOFF PLC 5 9.1 (P.32) 3.(P.12) -80- 5(P.23) 9.1 (P.32) 3.4 (P.16) 10.
Cycle Time 0.4 to 6.3 ms (by 0.1 ms) 6.4 to 31.6 ms (by 0.4 ms) 32 to 132.8 ms (by 1.6 ms) 0.4 to 132.8 ms Set the vendor ID. It is compared against the vendor ID of the connected IO-Link device when the device comparison function is enabled 0 to 65535 dec (Default value is 0) Set the vendor ID of the device to be connected. Vendor ID Set the device ID.
Other parameter settings Item Page Default setting [F 3] Digital filter setting Page 36 0 ms [F 4] Auto-preset function Page 37 Not used [F 5] FUNC terminal setting Page 39 Analog output [F 6] Fine adjustment of display value Page 41 0% [F10] Sub display setting Page 42 std (Standard) [F11] Display resolution setting Page 48 1000-split [F80] Power saving mode Page 49 OFF [F81] Security code
) Clean One-touch fittings D MS Applicable tubing O.D.
10^4 7: 10^5 8: 10^6 AC_E_L (Setting L of the accumulated flow value conversion factor) Setting of the accumuated flow value conversion factor Unit specification (Unit): When "L" is selected. 1071 0x042F 0 R/W U8 2 Y 0: 10^-2 1: 10^-1 2: 10^0 3: 10^1 4: 10^2 5: 10^3 6: 10^4 7: 10^5 8: 10^6 Accumulated value setting AC_E_G (Setting G of the accumulated flow value conversion factor) Setting
() MS LED NS LED IP 5.1 (IP ) (1)PLC (2)PLC (3) NS LED (1)PLC (2)PLC (3) NS LED NS LED IP 5.1 (IP ) -104No.JXC-OMT0001CN-C 2.3 6. 13.
Refer to back page 6 for changing the type of actuation. Manifold Option Description Part no.
Check the state GW unit MS LED Refer to fault of the GW unit. is OFF. No.1. GW unit MS LED Refer to fault is ON red. No.2. GW unit MS LED Refer to fault is flashing red. No. 3. GW unit MS LED is flashing green. Refer to fault No. 4. GW unit NS LED Refer to fault is OFF. No. 5. GW unit NS LED is Refer to fault ON red No. 6. GW unit NS LED is Refer to fault flashing red. No. 7.
) port] (Distance (11.7) between ports) (Distance between ports) Manual override Manual override 1.7 1.7 26.4 26.4 4A 4A 12 10 2B 2B (1.6) (1.6) G: Approx. 300 H: Approx. 600 G: Approx. 300 H: Approx. 600 41.5 41.5 80 (6) 80 (6) (Lead wire length) (Lead wire length) (13.4) (Distance (Indicator light) between ports) + 44.5 5EA (45) (55) 35 6 14.5 21.5 17.5 3EB M5 x 0.8 [5(EA), 3(EB) port]
or less (With anti-chattering function: 24 ms, 192 ms and 768 ms selections) Yes 3 1/2 digit LED display (Sampling cycle: 5 times/sec.)
ms Non safe valve output delay : 2 ms single fault diagnostic detection time : < 15 min Device acknowledge time (DAT) : <= 10 ms For calculating/determining the response time (safety function response time SFRT) please look at the user manual of the used safe profinet controller.