55.4 28.9 PF3A702H 72.3 51 73 71 35.5 -56No.PF-OMX0007-A Lead wire with M12 connector (ZS-37-A) Pin number Description Colour 1 DC(+) Brown 2 FUNC White 3 DC(-) Blue 4 OUT Black : 4-wire lead wire with M12 connector for PF3A series.
Input signal: Connect input wire to GND for 5 ms or longer
Refer to fault SI unit SI unit MS LED is No.1 OFF malfunction Refer to fault SI unit PWR(V) LED No.2 is OFF Yes No Refer to fault SI unit L/A LED is No.3 OFF Refer to fault SI unit MS LED is No.4 red ON Refer to fault SI unit MS LED is No.5 red flashing Refer to fault SI unit MS LED is No.6 green flashing Refer to fault SI unit MS LED is SI unit NS LED is No.7 green ON OFF Refer to fault
Normal condition (NOR): Flow measurement reference condition 101.3 kPa, 0 C. -55No.PF-OMJ0006-J Piping port specifications Model 01 02 N01 N02 F01 F02 C4 C6 C8 N7 4 8 6 1/4 (5/32") (5/16") Thread type (Port size) Rc Rc NPT NPT G G OneOneOneOne1/8 1/4 1/8 1/4 1/8 1/4 touch fitting touch fitting touch fitting touch fitting Straight without flow adjustment valve 95 g 125 g 55 g Bottom entry
4 !5 !7 !8 !9 @0 @8 #4 $2 $3 $9 %2 ^0 ^7 Qty. 1 1 1 1 2 2 2 2 2 4 2 1 1 2 2 4 2 2 6 4 8 2 6 2 1 2 4 4 3 4 4 1 1 4 1 4 2 1 1 1 2 2 1 1 1 2 1 1 1 8 4 2 1 6 No. q w e r t y u i o !0 !1 !2 !3 !
N.O. + P. 4-4-37 SYJ300 Push-turn locking slotted type Note) For AC For AC 0.36 2 3 (A R) M5 x 0.8 With light/surge voltage suppressor 100 VAC Hz 110 VAC Hz 200 VAC Hz 220 VAC Hz 50 60 50 60 50 60 50 60 P. 4-4-4 SYJ500 Push-turn locking lever type DIN terminal 1.2 2 3 (A R) 1/8 (SYJ500, 700 only) P. 4-4-18 SYJ700 M8 connector 2.7 2 3 (A R) 1/8, 1/4 P. 4-4-37 Note) All AC voltage
position 0.3 x P + 0.1 to 0.9 MPa (P: Operating pressure) Pressure center VFR (B) (A) 4 2 VQ7 (EA)(P)(EB) 5 1 3 Model Flow characteristics (1) Response (3) Model Max. (2) Mass (4) (kg) Port size 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) Type of actuation time (ms) Plug-in Non plug-in operating cycle (Hz) C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv 17 0.36 4.7 18 0.40 5.0 20 0.28 5.2 23 0.32 6.2
(mm)
Inappropriate specifications Leave an interval of a minimum of 15 ms (recommendation is 30 ms) between input signals and maintain the state of the signal for a minimum of 15 ms (recommendation is 30 ms), because PLC processing delays and driver scanning delays can occur. 8.4 Response time for the driver input Check the timing of the signal from the PLC to the driver.
Turn clockwise to release the lock. (4) (3) Stop switch (5) (4) Stop guard Protector for the stop switch Switch to prevent unintentional operation of Jog test function.
/C6 (6) C6 (6)/N7 (1/4") C8 (8)/N7 (1/4") Screw-in (Rc, NPT, G) 01 (Rc1/8)/N1 (NPT1/8)/F1 (G1/8) 02 (Rc1/4)/N2 (NPT1/4)/F2 (G1/4) Piping entry direction Straight, Rear Main materials of parts in contact with fluid PPS, PBT, FKM, Stainless steel 304, Brass (Electroless nickel plating), Si, Au, GE4F Piping*15 Body One-touch fitting Straight: 40 g Rear: 55 g Straight: 48 g Rear: 63 g Screw-in
4) Connector (Option) 1 CH 2 3 4 r Pin no.
1*2 gal/min 6*1*2 V V gal/min 7*1*2 V gal/min Port size Symbol Port size Applicable model LFE1 LFE2 LFE3 3 3/8 V 4 1/2 V 6 3/4 V 8 1 V *1 Options 4, 5, 6, and 7, which are not in SI units, are not for use in Japan due to the New Measurement Law. *2 Options 4, 5, 6, and 7 cannot be selected when the output specification is J or K.
;200 million cycles VQC21fi): 20 ms 2 ms;2fi) million cycles For r,lf, srunh vQc4loo: 17 ms 3 ms; 100 million cycles P!
Available response time settings 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms Principle This function averages pressure values measured during the response time set by the user and then compares the average pressure value with the pressure set point value to output the result on the switch.
M5 01 N01 C4H C6H N7H C4L C6L N7L Port size M5 x 0.8 R1/8 NPT1/8 4 mm One-touch fitting Straight type 6 mm 1/4 inch 5/32 inch 4 mm One-touch fitting Elbow type 6 mm 1/4 inch 5/32 inch Pressure-sensing part Silicon Materials in fluid contact Piping port (Common) PBT, CB156, heat resistant PPS, O-ring: HNBR C3604 (Electroless nickel plating), SUS304, NBR part POM, SUS304, NBR, C3604 Piping
Pin description 1 2 3 4 DC (+) OUT (2) DC () OUT (1) 1 2 3 4 4 Black 3 Blue 43
Check the state GW unit MS LED Refer to fault of the GW unit. is OFF. No.1. GW unit MS LED Refer to fault is ON red. No.2. GW unit MS LED Refer to fault is flashing red. No. 3. GW unit MS LED is flashing green. Refer to fault No. 4. GW unit NS LED Refer to fault is OFF. No. 5. GW unit NS LED is Refer to fault ON red No. 6. GW unit NS LED is Refer to fault flashing red. No. 7.
Piping/weight specifications Product No. 02(L) N02(L) F02(L) C01(L) A2(L) B2(L) Port size R1/4 NPT1/4 G1/4 Rc1/8 URJ1/4 TSJ1/4 fluid contact Materials in part Pressure-sensing part Pressure sensor: SUS630, Fitting: SUS304 Body (Rear piping) 51 g 51 g 48 g 47 g 54 g 46 g Weight Body (Bottom piping) 77 g 78 g 74 g 65 g 81 g 72 g Lead wire with connector +39 g Leakage 1 x 10-5Pa m3/s 1 x 10
Normal output Reversed output P_1 = A (A B)/4 n_1 = B + (A B)/4 A = Maximum pressure H_1 = (A B)/2 H_1 = (A B)/2 B = Minimum pressure In the OUT2 setting, the above P_1, n_1 and H_1 will be P_2, n_2 and H_2 respectively.