3/8 1/2 3/4 3/8 1/2 3/4 3/8 1/2 3/4 3/8 1/2 3/4 3/8 1/2 3/4 Solenoid Plug-In Factor 4.4 5.4 5.7 4.4 5.4 5.7 3.7 4.6 4.8 3.9 4.8 5 3.9 4.8 4.9 2.2 2.7 2.8 Time (ms) Single NVFS5100 45 or less 2 Position Double NVFS5200 25 or less Closed Center NVFS5300 55 or less Exhaust Center NVFS5400 55 or less 3 Position Pressure Center NVFS5500 55 or less Perfect (Double Check) NVFS5600 60 or less T E
Example) Alarms were generated in order of (1) (5) 7 to 0 Alarm 3 Alarm 1 (The latest) (1) (2) (3) (4) (5) 8 Alarm 2 0 (1) (2) (3) (4) Alarm 3 0 0 (1) (2) (3) Alarm 4 0 0 0 (1) (2) F to 8 Alarm 4 (1) to (5) in the table indicate the codes for the generated alarms. Please refer to "16.1 Alarm details" for the alarm details. The executed instruction code is output.
ISA-2-1 ISA-2-2 ISA-2-3 ISA-2-4 ISA-2-5 ISA-2-6 ISA-2-7 ISAl-1 ISAl-2/ISAl-1 ISAl-3/ISAl-2 ISAl-4/ISAl-3 ISAl-5/ISAl-4 ISAl-6/ISAl-5 ISAl-6 No.
. 8 mm 50 g Horizontal table mounting = 0 L1 = 30 mm L2 = 10 mm L3 = 0 mm 10 m Tp = 150 ms 4 N 4 mm Pushing direction away from the connector 4 s 10 s Stroke St [mm] Load mass W [g] Mounting orientation Mounting angle [] Amount of overhang (L1, L2, L3) [mm] Correction values for the distances to the moment center An [mm] Measuring accuracy [m] Positioning time Tp [ms] Pushing force
Pin arrangement 1 2 Solid state switch Standard part no. 3 4 4 3 3 For the applicable auto switch model, refer to the table below.
Piping port 02: R1/4 N02: NPT1/4 3.5 8.8 Atmospheric vent port 2.6 14.7 25.1 46.2 2 12.4 26.2 10.1 8.45 22 14.5 Piping port Rc1/8 Piping port G1/4 -F02: G1/4 -C01: Rc1/8 27.7 21.7 8.45 8.45 Piping port TSJ1/4 Piping port URJ1/4 -B2: TSJ1/4 -A2: URJ1/4 736 Series ZSE80/ISE80 2-Color Display Digital Pressure Switch For General Fluids Dimensions ZSE/ISE802L N02L C01L A2L B2L 2 41 25.2 30 20
less (with load current of 80 mA) Response time 2.5 ms (Response time selections with anti-chattering function: 20 ms, 160 ms, 640 ms, 1000 ms, 2000 ms) ZSP Short circuit protection With short circuit protection 0.5%F.S.
For external pilot specification L5 7 VQC (L4) (5) L2 (Rail mounting hole pitch: 12.5) L3 11 18.3 SQ 3/5 R 3/5 R A 4 A 4 A 4 L1 A 4 A 4 (Station n) .
3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) e w q r e w q r 2 position double 2 position double (A) 4 (B) 2 (A) 4 (B) 2 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) e w q e w q r r Note) 3 position pressure center 3 position exhaust center 3 position closed center 3 position pressure center 3 position exhaust center 3 position closed center (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B
or less 1 mS or less 1 mS or less I mS or less Output response -OffDefay lime -Internal voltage d~ 0.8 V or less 0.8 V or less 4 V or less 4 V or less Leak current 24 YDC: 10)l.A or less 24 VDC: 10).lA or less 24 VDC: 1 mA or less 24 VDC: 1 mA or less Response position: Response posihon: Response position: Response posilion: Indicator lamp Red: ON Red: ON Red: ON Red: ON Green: 8est position
Available response time settings 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms
(See Figure on page 59) Switch output NPN or PNP open collector output: 1 output NPN or PNP open collector output: 2 outputs Max. load current 80 mA Max. applied voltage 28 V (NPN output) Residual voltage 1 V or less (at 80 mA load current) 4 ms or less (with anti-chatter function: 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms, 10 s, 30 s or 60 s selected) Delay time Short circuit protection Provided
Pin arrangement 1 2 Solid state switch Standard part no. 3 4 4 3 3 For the applicable auto switch model, refer to the table below.
A 4 A 4 A 4 A 4 A 4 B A B A 14 A 14 A 1 P P 1 Fitting dimensions for panel mounting Refer to panel fitting dimensions for details.
(Linked to OUT1) Other parameter settings Item Page Default setting [F 3] Digital filter setting Page 39 0 ms [F 4] Auto-preset function Page 40 Not used [F 5] FUNC terminal setting 1 Page 42 Analogue output: 1 to 5 V/4 to 20mA [F 6] Fine adjustment of display value Page 46 0 [F10] Sub display setting Page 47 std (Standard) [F11] Display resolution setting Page 53 1000-split [F80] Power saving
3.5 x 7, 4 x 10 Thin section series (10 to 16) 4 Nylon tube 4 Urethane tube 4 tube 6 tube Applicable tube dia.
-01 1.5 0.08 1.4 0.5 0.3 (6A) VX312(0/2/4)-01 2.2 0.16 2.8 0.3 0.2 VX313(0/2/4)-01 3 0.24 4.3 Water 1 0.6 VX311(0/2/4)-02 1.5 0.08 1.4 0.5 0.3 VX312(0/2/4)-02 2.2 0.16 2.8 Oil 0.6 VX3224-02 2.2 0.19 3.4 1 VX3324-02 2.2 0.19 3.4 Air 0.3 0.2 VX313(0/2/4)-02 3 0.24 4.3 1/4 2 0.3 VX3234-02 3 0.33 6 (8A) 0.6 VX3334-02 3 0.33 6 0.15 VX3244-02 4 0.5 9 Steam 0.3 VX3344-02 4 0.5 9 0.6 VX3224-03
1) 15 ms or less 15 ms or less OFF 5 ms or less 5 ms or less PAX Note 1) JIS B 8375 (value of DC voltage specifications at 0.5 MPa supply pressure) (Value of high response time is subject to change upon pressure, quality of air.)