oC 5 to 60 (5 to 150 for high temperature type) Operating pressure Pa(abs) Atmospheric pressure to 1 x 10-5 Conductance l/s Note 1) 5 14 45 80 160 200 Internal 1.3 x 10-10 for the standard material (FKM) at ambient temperatures , excluding gas permeation Leakage Pam3/s External 1.3 x 10-10 for the standard material (FKM) at ambient temperatures , excluding gas permeation Flange type KF (NW

100, 125, 160, 200, 250, 320, 400, 500 2000 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 2000 100 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 2000 Ordering Example of Cylinder Assembly Cylinder model: CP96NDD50-100C-NW-M9BW

Normally closed (Pressurize to open, Spring seal) Fluid Inert gas under vacuum Operating temperature (C) 5 to 60 (High-temperature type: 5 to 150) Atmospheric pressure to 1 x 10-6 Operating pressure (Pa) (abs) Conductance (L/s) Note 1) 5 14 45 80 Internal 1.3 x 10-10 at normal temperatures (in case of standard material, FKM), excluding gas permeation Leakage (Pam3/s) External Flange type KF (NW

Magnet: D (Built-in), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 250 (2 1/2"), Stroke: 0300 (3"), Air Cushion: Both Ends (Air Cushion), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: MBPC (1.0m Cord Length, M8-4 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC35 (with Coil Scraper)

Magnet: Built-in, Mounting: MP2, Detachable Rear Clevis, Bore Size: 2 1/2", Stroke: 3", Air Cushion: Both Ends (Air Cushion), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 1.0m Cord Length, M8-4 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), X Option: with Coil Scraper

Nominal Size: 25, Speed Specifications: Standard 100 to 1000, Load Specifications: Standard Load, Nominal Size: 16(5), 25(10), Stroke: 150mm, Motor Placement: DA [On the Bottom (Left)], Output Type: NPN, Stoppable Positioning Points: A [5 Point (2 Ends + 3 Intermediate)], Cable Length: None, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector

Magnet: D (Built-in Magnet), Mounting: D (Double Clevis), Bore Size: 63mm, Thread: TN (NPT), Stroke: 350mm, Rod Boot: None, Cushion: Air Cushion, Pivot Bracket: No Bracket, Rod End Bracket: W (Double Knuckle Joint), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: Built-in Magnet, Mounting: Double Clevis, Bore Size: 63mm, Thread: NPT, Stroke: 350mm, Rod Boot: None, Cushion: Air Cushion, Pivot Bracket: No Bracket, Rod End Bracket: Double Knuckle Joint, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -

The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap

pressure Fluid Vacuum of inert gas Operating temperature oC 5 to 150 Operating pressure Pa(abs) Atmospheric pressure to 1 x 10-6 Conductance l/s Note 1 14 45 Leakage Internal 1.3 x 10-10 for the standard material (FKM) at ambient temperature, excluding gas permeation Pam3/s External 1.3 x 10-11 for the standard material (FKM) at ambient temperature, excluding gas permeation Flange type KF(NW

25 50 123 48 1 12 40 26 41 16 7.5 XLD-40 65 170 66 2 11 55 41 63 20 15 XLD-50 70 183 79 2 11 75 52 68 20 17.5 XLD-63 88 217 100 3 11 87 95 70 72 20 20 XLD-80 90 256 117 3 11 114 110 83 98 20 26.5 XLD-100 108 321 154 3 11 134 130 102 133 20 38 XLD-160 138 335 200 3 11 190 180 153 114 30 40 13 XL-OMY0002 8 X L D 25 M9N A A ( X A N1 A ) 25 40 B A 50 63 80 C P11 160 100 FKM() P8 KF (NW

Fluid Vacuum of inert gas Operating temperature oC 5 to 150 Operating pressure Pa Atmospheric pressure to 1 x 10-6 Conductance l/s Note 1) 5 14 45 80 Internal 1.3 x 10-10 for the standard material (FKM) Leakage at ambient temperatures , excluding gas permeation Pam3/s External 1.3 x 10-11 for the standard material (FKM) at ambient temperatures , excluding gas permeation Flange type KF (NW

Direction of exhaust Fixed Note 1 Operating pressure Pa (abs) Atmospheric pressure to 110-2 Conductance l/s Note 2 12 45 Operating power voltage 100VAC, 200VAC,110VAC,220VAC,230VAC,240VAC,24VDC,12VDC Electrical entry Grommet Pam3/s Internal 1.3 x 10-8 Leakage at ambient temperature, excluding gas penetration External 1.3 x 10-6 at ambient temperature, excluding gas penetration Type of flange KF(NW

-XC26 With split pins for double clevis pin/double knuckle joint pin and flat washers*4 Ordering Example of Cylinder Assembly -XC27 Double clevis and double knuckle joint pins made of stainless steel -XC29 Double knuckle joint with spring pin -XC30 Rod trunnion -XC35 With coil scraper -XC65 Made of stainless steel (Combination of XC7 and XC68)*2 Cylinder model: MDBD32-50Z-NW-M9BW Double clevis

300, 350, 400, 450, 500 Up to 1800 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Up to 2500 Cylinder model: MDWBD32-50-NW-M9BW