Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 1600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Valves: No, Operating Pressure(MPa): 0.08~1, Cushion: Air cushion, Port thread type
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Valves: No, Operating Pressure(MPa): 0.08~1, Cushion: Air cushion, Port thread type
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Valves: No, Operating Pressure(MPa): 0.08~1, Cushion: Air cushion, Port thread type
Dimensions Model D1 D2 D3 W Weight (kg) T0604-250-X64 475 200 52 120 5.1 T0604-500-X64 475 200 52 200 9.4 TH0604N-250-X64 475 200 52 120 9.4 D1 TH0604N-500-X64 475 200 52 220 18.5 D3 W D2 Related Products One-touch Fittings KQ2 Body type: Total 51 models Metal One-touch Fittings KQB2 Fluid temperature: 5 to 150C Applicable tubing O.D.
4 @1 w @4 !0 y !3 !5 @3 !0 !
Nil W Matsushita Electric Industrial Co., Ltd.
Series LTF6 Standard Motor Vertical Mount 100 W 10mm/10mm lead. Series LTF6 Standard Motor Vertical Mount 100 W 10mm/6mm lead. Series LTF6 Standard Motor Vertical Mount 100 W 10mm/10mm lead. Series LTF8 Standard Motor Vertical Mount 200 W 15mm/10mm lead. Series LTF8 Standard Motor Vertical Mount 200 W 15mm/20mm lead. Series LTF8 Standard Motor Vertical Mount 200 W 15mm/10mm lead.
250-S (Refer to page 44 for both ends tapped and male thread dimensions.) 150 (1-1/2"), 200 (2"), 250 (2-1/2") P-port H-thread C-depth 4 places N-through hole Z Q J M2 bolt circle W M1 E I dia.
I T C H H O W T O O R D E R NCRB1BW R O TA R Y A C T U AT O R NCDRB1BW S A U T O S W I T C H L E N G T H O F L E A D W I R E D ...W/ Auto Switch Magnet ...Without Magnet Grommet 0.5m Lead W L Grommet 5m Lead W C Connector 0.5m Lead W CL Connector 3m Lead W CN Connector No Lead Wire M O U N T I N G B ...Basic F ...Flange T Y P E O F A U T O S W I T C H B O R E ( M M) P O R T L O C AT I O N
How to Order q w e r t y u i o !
), 0.37 lbs (0.17 kg) (DIN rail mounting) Non-magnetizing operation type Holding force lbf [N] 35.3 (157) 66.0 (294) 17.5 (78) 17.5 (78) 8.8 (39) 4.5 (20) Power consumption [W] Note 11) 3.6 5 Rated voltage [V] 24 VDC 10% Weight Weight/Motor parallel LEY16 LEY25 LEY32 Stroke [mm] Series 30 50 100 150 200 250 300 30 50 100 150 200 250 300 350 400 100 150 200 250 300 350 400 450 500 30 50 Step
(g) n: Stations W = 30n + 50 W = 37n + 63 W = 61n + 101 W = 79n + 127 W = 100n + 151 Note 1) For more than 10 stations (more than 5 stations in case of SS5Y7), supply pressure to P port on both sides and exhaust from EA/EB port on both sides.
Nil W Matsushita Electric Industrial Co., Ltd.
Up to 700 80 7 RS Q G 25 25 1500 250 Up to 700 80 12 32 32 1500 250 Up to 1000 80 21 RS H A 40 40 1500 250 Up to 1000 80 33 50 50 1500 250 Up to 1200 RZQ 80 47 63 63 1500 250 Up to 1200 80 84 MI W S 80 80 1500 250 Up to 1400 80 127 100 100 1500 250 Up to 1500 80 196 CEP1 Note 1)The cylinder performance may not be as expected when stroke is shorter than recommended stroke (1 to 249 stroke
stroke (inch) 056(9/16") With Auto Switch 0.1 1 10 100 100 Allowable lateral load for rod end : W (lbf) Piston speed (inch/sec) 400 300 250 200 150 106 075 056 10 1 0.1 0.01 0.5 1 1.5 2 2.5 3 3.5 4 0 Cylinder stroke (inch) With Auto Switch, Super Compact 100 Allowable lateral load for rod end : W (lbf) 400 300 250 200 150 106 075 056 10 1 0.1 0.01 0.5 1 1.5 2 2.5 3 3.5 4 0 Cylinder stroke
Bore size (mm) Contents 32 40 50 63 80 100 32 40 50 63 80 100 MBB32-PS MBB40-PS MBB50-PS MBB63-PS MBB80-PS MBB100-PS MBB32-PS-W MBB40-PS-W MBB50-PS-W MBB63-PS-W MBB80-PS-W MBB100-PS-W Set of the No. @9, #0, #1, #2 and #3. Set of the No. @9, #0, #1, #2 and #3. D-X Seal kits consist of items @9 to #3, and can be ordered by using the seal kit number corresponding to each bore size.
11 22 14 30 C8512 0.3 10 15 6 15 9 20 C8510 Head ( side ) C858 0.5 6 10 4 10 6 14 0.1 0.7 4 8 3 8 4 11 Clevis: N Rod trunnion: U 0.3 24 36 17 35 22 46 0.5 18 27 12 26 16 W W 34 0.7 14 22 10 21 13 28 0.01 (40)1 (40)1 (40)1 (40)1 (100)1 0.3 80 400 350 300 250 200 150 100 50 450 0 (40)1 (40)1 Cylinder stroke [mm] Rod (side) 0.5 38 30 61 77 Head trunnion: U (40)1 0.7 35 32 25 51 64 W C85 Series
Refer to the electrical power waveform to the left. 0.1 w 0.1 w 0.35 w 0.35 w With power saving circuit 0 V 0.4 (0.95) W With power saving circuit 0.1 (0.4) W Only products with an indicator light are equipped with the power saving circuit.