P1 LED lever meter Sensor S1 S3 Red is on: Output OFF Green is on: Output ON S4 S2 + P2 Red 1 Gap too big S1, S2: Fixed orifice S3: Variable orifice (Set via adjustment knob) S4: Detection nozzle Red 2 Green 1 BEST POSITION The bridge circuit is constructed as shown in the diagram. Position the work piece in front of the nozzle (S4).
Port P Port R2 Unit mounting position IP65 available Kit T1 With terminal blocks 1 to 12 stations D side U side Without SI unit With general purpose type SI unit Mitsubishi: MELSECNET/MINI-S3 data link system Mitsubishi: MELSECNET/MINI-S3 data link system (2 power supply systems) OMRON: SYSBUS wire system Sharp: Satellite I/O link system NKE: Simplified wiring (16 point output) Sanks: S-LINK
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket
Magnet: None, Mounting: G (Head Flange), Bore Size: 32mm, Stroke: 300mm, Rod End Thread: G (Long Male Rod End)
Magnet: D (Built-in), Mounting: F (Rod Flange), Bore Size: 40mm, Stroke: 300mm, Rod End Thread: G (Long Male Rod End)
Size: 25, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: G (Head Flange)
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: G (Head Flange)
Magnet: None, Mounting: Head Flange, Bore Size: 32mm, Stroke: 300mm, Rod End Thread: Long Male Rod End, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Rod Flange, Bore Size: 40mm, Stroke: 300mm, Rod End Thread: Long Male Rod End, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 40mm, Stroke: 300mm, Rod End Thread: G (Long Male Rod End)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 20mm, Stroke: 300mm, Rod End Thread: G (Long Male Rod End)
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket
Size: 25, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Head Flange, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Head Flange, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length
EXH port P1 SUP port Sensor S1 S3 S2 S4 P2 Detection port S1, S2: Fix orifice S3: Variable orifice (adjusted by setting dial) S4: Detection nozzle 868 A Air Catch Sensor Series ISA2 Wiring Individual wiring Centralized wiring Terminal block 1: Brown 2: NC 3 0 1 2 3 4 Brown Blue Black DC (+) NC DC () OUT ZSE30 ISE30 OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 6 9 3: Blue DC () NC DC (+) OUT 6 ZSE40 ISE40
This reduces noise considerably compared with A much lower air consumption is required than the current model. the current model. 1: Conditions: Unseated for 5 seconds and seated for 20 seconds (For G type) Comparison of detection circuit ISA3 New New Current model (ISA2) A B EXH port EXH port P1 Sensor Sensor SUP port S1 S3 SUP port S2 Sensor S1 S4 S2 Detection port P2 Detection port C D
JSY1000 series clamp bracket Wiring (JSY1000 series) JSY11M-15P-1A JSY11M-15P-2A F D-sub connector V Pm Flat ribbon cable V TC Spring type terminal block box V T Terminal block box V L Lead wire V S6 EX600 V Sm EX250 V Smm EX260 V S3 EX120 V Manifold Parts Nos.
1 t LEM e Motor type*1 r Lead [mm] q Accuracy LEY Symbol Type Output [W] Actuator size Compatible driver*2 Nil Basic type H High precision type Symbol LEJS40 LEJS63 A 16 20 B 8 10 LES S2 AC servo motor (Incremental encoder) 100 40 LECSA-S1 w Size S3 AC servo motor (Incremental encoder) 200 63 LECSA-S3 LEPY LEPS t Stroke [mm]*3 40 63 S6 AC servo motor (Absolute encoder) 100 40 LECSB-S5 LECSC-S5