OUT1OUT2OUT3OUT4OUT5 AC100~240V Pulse counter M/C Flow control for each branch line For Air P.2 50l/min 10l/min 500l/min 200l/min 100l/min 12000l/min 6000l/min 3000l/min Flow rate measurement range l/min Integrated display type Remote type Output specifications Port size (Rc, NPT, G) 1/8 1/4 3/8 1/2 11/2 1 2 Switch output Analog output Accumulated pulse output Display unit Sensor unit PF2A710 750
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1/8 1/4 3/8 1/2 11/2 1 2 Switch output Analog output Accumulated pulse output Display unit Sensor unit PF2A710 750 711 721 751 703H 706H 712H PF2A510 550 511 521 551 1 to 10 PF2A30 5 to 50 10 to 100 31 20 to 200 50 to 500 150 to 3000 300 to 6000 600
PAT. 17-5-172 33 Flow Switch Series PF, IF For Air Digital Flow Switch/Series PFA Display integral type Output specification Port size (Rc, NPT, G) Flow rate range (l/min) Separate type Display Sensor Switch output Analog output Accumulated pulse output PFA710 750 711 721 751 703H 706H 712H PFA510 550 511 521 551 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 150 to 3000 300 to 6000 6000 to
VQZ3000 VFS VS 0.7 0.9 VS7 Bore size (mm) Cylinder speed (mm/s) Base mounted (With sub-plate) Cv Series CJ2 Series CM2 Series CA1 6 10 16 20 25 32 40 40 50 63 80 100 150 300 VQZ1000 Body width 10 450 0.3 V V V 600 750 150 300 VQZ2000 Body width 15 0.6 450 V 600 V V 750 150 300 VQZ3000 Body width 18 0.9 450 V V V V V 600 750 Cylinder speed marked with can be controlled by speed controller
Heat exchanger Radiating method W Water-cooled Temperature controller 007 B HED C 2 Cooling capacity Communication 003 005 007 A B RS-485 RS-232C 300 W 500 W 750 W Temperature controller Power supply 2 Single-phase 180 to 242 VAC 50/60 Hz 176
1,000 L5 [mm] L5 [mm] L5 [mm] 750 1,000 1,000 500 500 500 250 m Mey 00 1 2 3 4 5 00 0.1 0.2 0.3 0.4 0.5 00 0.5 1.0 1.5 2.0 L5 Work load m [kg] Work load m [kg] Work load m [kg] 28 Electric Slide Table/High Rigidity Type Series LESH Model Selection 2 Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Selection Procedure For the compact type LES series, refer to page 5.
5.50 1/2 NPT 4.50 .94 .95 2.88 2.75 2.500 1.38 7.13 1.375 1-14 1.63 2.000 1.530 1.000 6.50 3/4 NPT 5.00 1.31 1.32 3.13 3.25 3.000 1.63 8.13 10 MP2 Double detatchable head side clevis style (D) XD + Stroke A UB P + Stroke 2-EE MR MAX KK MM B CD (PIN) TH LR CB E WF LF + Stroke F Bore Size (in) MM KK A B CB CD E EE F LF+ LR MR P+ TH UB WF XD+ 500 (5") 1.000 3/4-16 1.13 1.500 1.280 .750 5.50
Station Address MECHATROLINK-III Communication Baud Rate 100 Mpbs Transmission Cycle 125 s, 250 s, 500 s, 750 s, and 1.0 ms to 4.0 ms (increments of 0.5 ms) Number of Transmission Bytes 16, 32, or 48 bytes per station Use the DIP switch S3 to select the number of words.
Process X+500 X+250 X (250 to 0) 250 (1000 to 751) (750 to 501) (500 to 251) data ISA3-H : The value in the brackets in level 2 shows the boundary value. -66No.PS-OMW0009-C 4 How to use X: Switch point is divided by weight.
Maximum acceleration: 2000mm/s Positioning time (sec.) 1500 750 100 10 1 Positioning distance (mm) 151.1 76.1 11.1 2.1 1.2 10 16.1 8.6 2.1 1.2 1.1 100 Speed (mm/s) The value is a guide when SMC's series LCI controller is used and may vary depending on the driver capacity. 7.2 4.2 1.6 1.2 1.1 250 4.3 2.8 1.5 1.2 1.1 500 Values will vary slightly depending on the operating conditions.
OUT1OUT2OUT3OUT4OUT5 AC100~240V Pulse counter M/C Flow control for each branch line For Air P.2 50l/min 10l/min 500l/min 200l/min 100l/min 12000l/min 6000l/min 3000l/min Flow rate measurement range l/min Integrated display type Remote type Output specifications Port size (Rc, NPT, G) 1/8 1/4 3/8 1/2 11/2 1 2 Switch output Analog output Accumulated pulse output Display unit Sensor unit PF2A710 750
Rc NPT G Symbol N M12 3 m lead wire with connector Without lead wire Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Port size Output specification Port size Applicable model Flow rate (l/min) Symbol Symbol Output specification 100 200 500 50 10 01 02 03 04 1/8 1/4 3/8 1/2 27 NPN open collector 2 outputs PF2A710/750 PF2A711/721 PF2A751 67 PNP open collector 2 outputs
Potential Amplitude Supply pressure: 0.3 MPa Applicable models: IZS40, IZS41 Applicable models: IZS42 1) With High speed static neutralization cartridge, For IZS40-1120, IZS41-1120 2) With High speed static neutralization cartridge, For IZS42-1120 200 2000 175 1750 Potential amplitude [V] Potential amplitude [V] 150 1500 V V 125 1250 0.1Hz 100 1000 1Hz 75 750 30Hz 30Hz 50 500 25 250 0 0 0
T dimension) 0 1 5 None Differential pressure indicator Differential pressure indication switch Note) 1 2 3 4 5 1 2 3 4 1 2 3 4 340 410 480 550 620 430 530 630 730 560 650 750 850 04 (1/2B) 06 (3/4B) 08 (1B) 30 FH FH Note) N.C. and N.O. common Note) When the differential pressure indication 1 or 5 is selected, the connection method is 2 to 5. (0 and 1 cannot be selected.)
15, 25 CY CY1H CY1F MG Standard stroke (mm) Maximum stroke Cushion Piping directions Bore size (mm) Model Height Overall length mm mm 150 200 250 300 350 400 450 500 550 600 50 100 CX 10 15 25 15 10 25 240 350 310 For 100mm stroke cylinder Series Series 10 500 CY1F CY1H CY1F CY1H MY2H Concentrated piping on right 28 34 46 46 63 198 225 205 294 260 DBuilt-in shock absorber 39.5 CY1F 15 750
Vertical Operation CY1L CY1L CY1L6 CY1L6 1 0 500 (650) 750 1000 1500 Bore size (mm) Allowable load mass (Wv) (kg) 1.53 1.6 + Lo CY1H Cylinder stroke (mm) 6 5.00 1.95 + Lo CY1F 10 15.96 2.4 + Lo 15 CYP 31.1 2.8 + Lo 54.48 3.1 + Lo 20 25 112.57 3.95 + Lo 212.09 4.75 + Lo 32 40 DLo: Distance from mounting surface to load center of gravity (cm) Note) Operating pressure should be
Symbol Specifications X01 Different diameters (IN side < OUT side) X02 Different diameters (IN side > OUT side) X03 Blue element X04 Filtration: 10 m X05 FKM/Oil free (Seal) X06 Nylon 5 20 L/min 750 mm2 7 100 L/min 1260 mm2 Applicable tubing O.D. Metric size Symbol Applicable tubing O.D.
750 750 850 850 6 9 9 9 12 12 12 16 16 460 665 693 693 1162 1162 1162 1416 1416 19 19 19 19 19 19 19 27 27 80 M16 x l 250 M16 x l 250 M16 x l 250 M16 x l 300 M16 x l 300 M16 x l 300 M16 x l 500 M24 x l 500 M24 x l 500 AT6C AT11C AT22C AT37C AT55C AT75C AT125C AT150C AT220C 1 2 Rc 1/2 Rc 3/4 Rc 1 Rc 1 Rc 1 1/4 Rc 1 1/4 Rc 2 Rc 2 Rc 2 Rc 110 110 110 180 180 180 260 260 Rc 3 4 Rc 1 1 2 1 2
When the piston speed exceed 750 mm/s, make sure that direct impact does not apply on the cylinder cover by using an external stopper (shock absorber, etc). Standard external (B) 17 25 35 36 46 60 70 86 100 Dimensions except mentioned above are the same as standard type.
Area: (800) 258-9200-www.stevenengineering.com Piping directions Maximum stroke Cushion Bore size (mm) Model Height Overall length mm mm 150 200 250 300 350 400 450 500 550 600 50 100 CX 10 15 25 15 10 25 240 350 310 For 100mm stroke cylinder Series Series 10 500 CY1F CY1H CY1F CY1H MY2H Concentrated piping on right 28 34 46 46 63 198 225 205 294 260 DBuilt-in shock absorber 39.5 CY1F 15 750