SMC Corporation of America
Elite Part Number Search
Search Results "LEFB40US4S-1000-S2"

Material N N B R S Silicone rubber u urethane rubber F Fluorine rubber GN Conductive NBR (s2-o 16) GS Conductive silicone (s2-o16) Material N N B R s silicone rubber u _ urethane rubber F Ftuorine rubber GN Conductive NBR (o2-o16\ GS Conductive silicone (@2-@'16) Pad type (application: Refer to list O) U Flat type c Ftat with rib D Deep type B Bellows type Pad type U Flat type c _ Flat vYith

Auto Switches Common Specifications Type Reed auto switch Solid state auto switch 1 ms or less 1.2 ms Operating time 300 m/s2 1000 m/s2 Impact resistance 50 M or more at 500 VDC Mega (Between lead wire and case) Insulation resistance 1500 VAC for 1 minute (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire and case) Withstand voltage 10 to 60C Ambient temperature IEC60529

Do not drop, bump or apply excessive impacts (300 m/s2 or more for reed switches and 1000 m/s2 or more for solid state switches) while handling. Although the body of the auto switch may not be damaged, the inside of the auto switch could be damaged and cause a malfunction. 2. Mount auto switches using the proper tightening torque.

The station address is set using the rotary switches S1 and S2. (1) Settings of the Rotary Switches S1 and S2 Set the station address using the rotary switches S1 and S2.

T1 T2 T3 T4 T1 = V/a1 [s] T3 = V/a2 [s] L : Stroke [mm] (Operating condition) V : Speed [mm/s] (Operating condition) a1: Acceleration [mm/s2] (Operating condition) a2: Deceleration [mm/s2] (Operating condition) P T2: Constant speed time can be found from the following equation.

For 4 Axes Step Axis Movement mode Speed Position Acceleration Deceleration Positioning/ Pushing Area 1 Area 2 In position Comments mm/s mm mm/s2 mm/s2 mm mm mm Axis 1 ABS 100 200.00 1000 1000 0 6.0 12.0 0.5 Axis 2 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 0 Axis 3 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 Axis 4 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 Axis 1 INC 500 250.00 1000 1000 1 0 0 20.0

(with no condensation) Withstand voltage 1000 VAC for 1 min. between external terminal and case 50 M or more (500 VDC Mega) between external terminal and case Insulation resistance Without orifice: 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller.

]*2 20 Impact resistance [m/s2]*3 100 ZL3 ZL6 Branch With valve *1 Values are at the standard supply pressure and based on SMCs measurement standards.

Bore size CS1, CS2 series Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm MB, CA2 series Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Average speed [mm/s] Series 40 50 63 80 100 125 140 160 180 200 250 1100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal VQ4100--03 VQ4101--03 1100 1000 900 800 700 600 500 400 300 200 100 0 VQ5100--04 VQ5101--04 Values at extension

MHF Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MHL Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MHR 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MHK 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and

MHF Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MHL Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MHR 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MHK 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and

Cylinder stroke (mm) Bore size (mm) Standard stroke (mm) Max. stroke with switch (mm) Max. stroke without switch (mm) 50, 100, 150, 200, 250, 300, 350 400, 450, 500 15 1000 750 20 25 32 1000 1200 1500 100, 150, 200, 250, 300, 350, 400 450, 500, 600, 700, 800 100, 150, 200, 250, 300, 350, 400 450, 500, 600, 700, 800, 900, 1000 2000 1500 40 Note 1) The longer the stroke, the larger the amount

Single solenoid Lead wire length AXT661-12AL 300 mm 600 mm 1000 mm 2000 mm 3000 mm AXT661-12AL 300 mm 600 mm 1000 mm 2000 mm 3000 mm Socket only (3 pcs.)

Mount the switch in a locations where there is no vibration greater than 98 m/s2 or impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.

Note 4) Grommet type (G) is also available for C-kit, single type of VQ0/1000/2000.

1000 80 80 0 0 2 2000 2000 100 100 0 0 3 4000 2000 70 60 500 1 4 500 2000 60 70 1000 1 5 1000 2000 80 80 0 0 6 2000 1000 80 80 0 0 7 1000 1000 80 80 0 0 8 1000 1000 100 100 0 0 LEC-MR-J3BAT 1000 1000 100 100 0 0 C N 4 ( 3 ) 255 2000 2000 80 80 0 0 RS-422 USB CN 6 CN 1 CN3 CN5 DI/O ON USB CC-Link RS-422 1.

Up to 600 Up to 1000 Up to 600 Up to 1000 Up to 750 Up to 1000 Up to 750 Note) End boss is machined on the flange for E.

/s2 (Without pressure sensor and pressure switch, With pressure sensor) Impact resistance Note 2,3) 100m/s2 (With pressure switch) Standard CE, RoHS Note 1) The characteristics are satisfied when tested for 2 hours in each of the X, Y and Z directions at 10 to 500 Hz without energization.

in X, Y, Z directions for 2 hrs. each (De-energized) 100 m/s2 in X, Y, Z directions 3 times each (De-energized) 2% F.S.