SMC Corporation of America
Elite Part Number Search
Search Results "JSY11M-39-1A-C4"

VDW1: VDW10S-12A-1 VDW2: VDW20S-12A-1 M U Y W X 11 Size 39 VDW1 VDW2 11 28 17 34 15 33 20 14 Enter symbols in the order to the right when ordering a combination of electrical option, other options, and bracket interchangeable with old type. Example) VDW Z Z 1A XB 2 0 A Electrical option Bracket interchangeable with old type Other option Construction Normally closed (N.C.)

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 39 39 40 40 41 41 43 45 47 54 54 55 55 56 60 65 68 70 70 71 71 72 77 78 82 84 87 89 91 93 96 97 98 99 99 100 101 102 Series MSUB Rotary Table: Basic Type Vane Style Size: 1, 3, 7, 20 . How to Order . Specifications. Construction. Dimensions .

P . 14-2-39 14-2-34 35 Air Filter Series AF10 to 60 Flow Characteristics (Representative values) Precautions AF10 M5 AF40-06 Rc 3/4 0.10 0.10 Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions.

3.3.1 39 3.3.2 39 3.4 3-10 3.5 CPU( 3-10 3.5.1 3-10 3.5.2 3-14 3.5.3 3-23 3.5.4 (RWwn2RWwn3) 3-24 3.5.5 (RWrn2) 3-32 3.5.6 CN6 3-33 3.6 3-35 3.6.1 3-35 3.6.2 3-37 3.6.3 3-39 1 - 3.7 3-42 3.7.1 3-42 3.7.2 3-45 3.7.3 3-46 3.7.4 3-47 3.7.5 3-50 3.7.6 3-53 3.8 3-56 3.8.1 1 3-56 3.8.2 1 3-57 3.8.3 2 3-59 3.8.4 2 3-60 4 414-40 4.1 43 4.2 46 4.3

Output data Offset Meaning MSB LSB MSB LSB (INT) 15 8 7 0 D4 #D3 #D2 #D1 #C4 #C3 #C2 #C1 #B4 #B3 #B2 #B1 #A4 #A3 #A2 #A1 Slave 8 connection diagnosis 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 In the figure above, #A1 to #A3 are slaves for which the connection is diagnosed. In this case, #A3 slave is not connected, and a diagnostic error is generated.

U side 1 2 3 4 5 n Direct manual override (Non-locking) 2n x C4, M5 4(A), 2(B) port C4: One-touch fitting for 4 M5: M5 thread 2(B) 2(B) 27.5 20 15 4(A) 4(A) 5 P = 11 12.5 (46) L plug connector (L) n: Stations Dimensions n L 11 138 130 10 127 119 L1 L2 2 39 31 3 50 42 4 61 53 5 72 64 6 83 75 7 94 86 8 105 97 9 116 108 12 149 141 13 160 152 14 171 163 15 182 174 16 193 185 17 204 196 18 215

Straight portion length 1/8" 6 1/4" 8 10 12 Nylon tubing Soft nylon tubing Polyurethane tubing 44 or more 84 or more 89 or more 112 or more 140 or more 168 or more 16 or more 30 or more 32 or more 40 or more 50 or more 60 or more 25 or more 39 or more 57 or more 52 or more 69 or more 88 or more 29 or more 39 or more 56 or more 58 or more 70 or more 82 or more 4.

Symbol: C4 Symbol: C1 Add connection ports on Body (A). (An additionally machined port will have an aluminum surface since it will be left unfinished.) Change of rotation.

Symbol: C4 Symbol: C1 Add connecting ports on Body (A). (An additionally machined port will have an aluminum surface since it will be left unfinished.) Change of rotation.

Symbol: C4 Symbol: C1 Add connection ports on Body (A). (An additionally machined port will have an aluminum surface since it will be left unfinished.) Change of rotation.

AXT502 1A < Manifold block replacement parts > Cylinder port position Description Material Qty. Part No.

PRESSURE SWITCHIS10M-20-D to IS10M-60-D Model IS10M-20-D IS10M-30-D IS10M-40-D IS10M-50-D IS10M-60-D A B C D 28 77.6 60.1 42 31 85.6 64.1 53 39 93.6 68.1 71 47 96.6 69.6 71 62 106.6 74.6 90 11-2.

Unit: mm Mounting pitch A Straight Tube portion length size Nylon tube Soft nylon tube Polyurethane tube 1/8" 44 or more 84 or more 89 or more 29 or more 39 or more 56 or more 58 or more 70 or more 82 or more 25 or more 39 or more 57 or more 52 or more 69 or more 88 or more 16 or more 30 or more 32 or more 40 or more 50 or more 60 or more 2.

39 N 61 (68) 69 (76) 79 (89) N 61 (68) 69 (76) 79 (89) Q 23 23 Energized closed VXD2142 47 47 48 65 78 86 42 46 56 52 56 66 104 (116) 44 59 66 28 35 40 3 8 8 14 29 37 43 34 43 47 20 20 23 92 92 95 59 59 62 30 30 35 57 74 81 34 51 58 39 63 80 90 26 3 8, 1 2 32.5 17.5 20 45.5 118 (136) 3 4 VXD2150 VXD2260 1 VXD2152 VXD2262 25.5 41.5 36.5 49.5 133 (150) ( ): N.O. 4.1-24 VXD21/22/23 Dimensions

63 68 69 96 39 63 68 69 96 XLG-50 XLG-63 88 95 110 Note 1) Dimension E applies when heater option is included.

Combination PS ZQ Philips screw Vacuum switch ZSE3, ZSP1 Vacuum switch ZSE2 M2.5 x 63 M2.5 x 61 P3270148-39 (M2.5 x 39) PV M2.5 x 14 ZF Filter unit ZX1-F Plate A P3200150 ZP ZCU Ejector assembly AMJ 1(PV PS PD) PD PE Misc.

(Stations 7 to 8) SS0752-08C S0712-5G-C4 S0722-5G-C4 S0732-5G-C4 S07A2-5G-C4 Body Ported Manifold Bar Base Voltage Symbol Type 5 24 VDC 6 12 VDC Note) The valve cannot be used as a standalone unit. Prefix the asterisk to the part numbers of the solenoid valve etc. Write sequentially from the 1st station on the D side.

, C6 C4: One-touch fitting for 4 C6: One-touch fitting for 6 2-C4, C6 C4: One-touch fitting for 4 C6: One-touch fitting for 6 4.5 4.5 M3 mounting hole M2.5 mounting hole Residual pressure release manual override DIN rail clamp screw 2n-C3, C4, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread D side U side Stations 1 2 3 Dimensions

or less 0.16 0.26 0.58 0.15 0.20 0.64 25 or less 100 Rubber seal Exhaust center 10-SQ1431 39 or less 0.19 0.20 0.80 0.15 0.20 0.64 25 or less 100 Rubber seal Pressure center 10-SQ1531 39 or less 0.14 0.20 0.59 0.19 0.21 0.79 25 or less 100 Rubber seal Note 1) Values for the cylinder port size of C6, CYL Values of EXH.

In this case, mounting screws P3270148-39 (2 pcs.) are required. If the unit is used on its own, not combined with others, D is not required. Ex.)