This is a legacy product. Please contact us for the latest version.sales@ocaire.com

The standard IS10M pressure switch cannot be set to 0.4 to 0.45 MPa because 0.4 MPa is the upper limit of the set pressure range.
For AC-A/AC-B series modular F.R.L units with a white body, the pressure switch must be replaced with an IS10M-□-6-A pressure switch (set pressure: 0.1 to 0.6 MPa).

Part Number Description: FITTING   Product Line: C   Product Line Description: CONNECTORS   Family Code: 700   Family Description: D SELF ALIGN FITTINGS   Class Code: LP   Part Code: 1   Reference Code:  C   Click here to report information errorImage shown may not match exact part number

There are 10 styles available including electroless nickel plated for copper-free applications., FITTING W/CHECK, CONNECTORS, KC SELF SEAL FITTINGS, LP, KC 12MM, .06298 lb

Piping: 5 (Body Ported), Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Bracket: B (Bracket), Option: LP (Indicator Light, Manual Override)