Please contact us for the latest version.sales@ocaire.com, POSITIONER, PNEU-PNEU, LEVER, INSTRUMENTATION, IP8000/8100 POSITIONER, 2A, IP8000/8100 NO SIZE PT VERSION, 6.39340 lb
Please contact us for the latest version.sales@ocaire.com, POSITIONER, PNEU-PNEU, LEVER, INSTRUMENTATION, IP8000/8100 POSITIONER, 2A, IP8000/8100 NO SIZE PT VERSION, 5.50052 lb
Please contact us for the latest version.sales@ocaire.com, POSITIONER, PNEU-PNEU, LEVER, INSTRUMENTATION, IP8000/8100 POSITIONER, 2A, IP8000/8100 NO SIZE PT VERSION, 5.95248 lb
Output restriction w/pilot valve, fork lever joint, compensation spring, w/external scale plate, IP8000/8100 NO SIZE PT VERSION, INSTRUMENTATION, IP8000/8100 POSITIONER, 2A, IP8000/8100 NO SIZE PT VERSION, 6.6999 lb
Output restriction w/pilot valve, fork lever joint, compensation spring, w/external scale plate, IP8000/8100 NO SIZE PT VERSION, INSTRUMENTATION, IP8000/8100 POSITIONER, 2A, IP8000/8100 NO SIZE PT VERSION, 6.08475 lb
Output restriction w/pilot valve, fork lever joint, compensation spring, w/external scale plate, IP8000/8100 NO SIZE PT VERSION, INSTRUMENTATION, IP8000/8100 POSITIONER, 2A, IP8000/8100 NO SIZE PT VERSION, 5.73201 lb
BASE SEAL (IP8000/8100), BASE SEAL (IP8000/8100), INSTRUMENTATION, IP8000/8100 POSITIONER, 21, IP8000/8100 NO SIZE RATING, .94600 lb
COVER SEAL (IP8000/8100), COVER SEAL (IP8000/8100), INSTRUMENTATION, IP8000/8100 POSITIONER, 21, IP8000/8100 NO SIZE RATING, .94600 lb
Low concentration EG in the circulating fluid may cause system failure due to it being frozen in the system. High concentration EG in the circulating fluid may cause circulating pump overload, which triggers Return Low Flow FLT. Potential cooling error may occur if the circulating fluid varies in concentration.
Calculating method-Take out the lower 1 byte of the total. eg.) Set temperature to 30 deg.C (without unit specified) STX 31H 33H 30H 30H 30H ETX 3FH 34H CR Total F4H eg.) Read Thermo-con internal sensor of unit No.2 SOH 32H 05H 32H 36H 39H CR Total 69H Note) Check sum is not ASCII code.
Calculating method-Take out the lower 1 byte of the total. eg.) Set temperature to 30 deg.C (without unit specified) STX 31H 33H 30H 30H 30H ETX 3FH 34H CR Total F4H eg.) Read Thermo-con internal sensor of unit No.2 SOH 32H 05H 32H 36H 39H CR Total 69H Note) Check sum is not ASCII code.
Calculating method -Take out the lower 1 byte of the total. eg.) Set temperature to 30oC (without unit specified) STX 31H 33H 30H 30H 30H ETX 3FH 34H CR Total F4H eg.) Read Chemical Thermo-con internal sensor of unit No.2 SOH 32H 05H 32H 36H 39H CR Total 69H Note) Check sum is not ASCII code.
Low concentration EG in the circulating fluid may cause system failure due to it being frozen in the system. High concentration EG in the circulating fluid may cause circulating pump overload, which triggers Pump Breaker Trip FLT.
Low concentration EG in the circulating fluid may cause system failure due to it being frozen in the system. High concentration EG in the circulating fluid may cause circulating pump overload, which triggers Pump Breaker Trip FLT. Potential cooling error may occur if the circulating fluid varies in concentration.
Actuators movement distance per pulse is obtained as below: actuators movement distance per pulse (mm/pls) actuators lead (mm) 1 / no. of encoders pulses2 lead length (mm) / 262144(pulse) eg.
Actuators move distance per pulse is obtained as below: actuators move distance per pulse (mm/pls) actuators lead (mm) 1 / no. of encoders pulses2 lead length (mm) / 4194304(pulse) eg.
Example of Mounting on Actuator IP8001 Smart Positioner offers interchangeability in mounting pitch with the IP600, IP6000 and IP8000 Positioners. Therefore, it is possible to apply a bracket for IP600, IP6000 and IP8000 for mounting*1. Directly attach using the screw hole at a side of the positioner and the screw hole at the yoke side of diaphragm.
Output restriction w/pilot valve, fork lever joint, compensation spring, w/external scale plate, POSITIONER, PNEU-PNEU, ROTARY, INSTRUMENTATION, IP8000/8100 POSITIONER, 2A, IP8000/8100 NO SIZE PT VERSION, 6.41038 lb
Output restriction w/pilot valve, fork lever joint, compensation spring, w/external scale plate, POSITIONER, INSTRUMENTATION, IP8000/8100 POSITIONER, 2A, IP8000/8100 NO SIZE PT VERSION, 5.68057 lb
/8100 POSITIONER, 2A, IP8000/8100 NO SIZE PT VERSION, 5.70261 lb