After returning to the origin position, the SETON and INP signals are output. 0 Absolute: 200 Operation w [Specify Step No.2 to input the DRIVE signal.] 200 Absolute: 100 Step data No. defining operation The operation starts by specifying a registered step data No. to input the DRIVE signal.
35.6 18 7 14.6 12.7 AS220-N02-ST NPT 1/4 NPT 1/4 AS220-F02-ST G 1/4 AS220-02-ST Rc 1/4 R 1/4 17 18 36.7 1.5 18 40.7 27.2 7 19.5 17.5 AS320-N02-ST NPT 1/4 NPT 1/4 AS320-F02-ST G 1/4 AS320-02-ST Rc 1/4 R 1/4 49.3 1.5 22.4 55.3 30 9.5 24.3 19 22.5 AS320-N03-ST NPT 3/8 NPT 3/8 AS320-F03-ST G 3/8 AS320-03-ST Rc 3/8 R 3/8 47.4 1.5 20.8 53.7 30 9.5 24.3 19 22.5 AS420-N04-ST NPT 1/2 NPT 1/2 AS420
Rc 1/8 12 14.3 R 1/8 AS22 0-F01-ST PF 1/8 14.6 7 18 35.6 14.1 1.5 32 AS22 0-N01-ST NPT 1/8 12.7 NPT 1/8 AS22 0-02-ST Rc 1/4 17 18 R 1/4 AS22 0-F02-ST PF 1/4 19.5 7 27.2 40.7 18 1.5 36.7 AS22 0-N02-ST NPT 1/4 17.5 NPT 1/4 AS32 0-02-ST Rc 1/4 19 22.5 R 1/4 AS32 0-F02-ST PF 1/4 24.3 9.5 30 55.3 22.4 1.5 49.3 AS32 0-N02-ST NPT 1/4 NPT 1/4 AS32 0-03-ST Rc 3/8 19 22.5 R 3/8 AS32 0-F03-ST PF 3/
ST Red flashing Pairing mode. (synchronized with SA) Red ON Component failure inside the AMS Hub. Orange flashing Internal communication error in wireless adapter. OFF Standalone mode. SA Green ON Wireless mode. Red flashing Pairing mode. (synchronized with ST) OFF Power not supplied. PWR Green flashing Power supply voltage is abnormal.
Rubber bumper is standard equipment for long stroke type. 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 Action 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 D Double acting 25 For "Manufacture of Intermediate Strokes", refer to page 7-4-5. Applicable Auto Switch/Refer to page 7-9-1 for further information on auto switches.
Bore size Stroke Max. stroke (mm) Bore size (mm) Standard stroke (mm) Standard Non-rotating Double rod 8 10 12 16 20 25 10, 25, 40, 50, 80, 100 100 100 400 10, 25, 40, 50, 80, 100, 125, 160, 200 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 200 200 1000 500 1000 Not available with air cushion. Other strokes available on request.
Bore size Stroke Max. stroke (mm) Bore size (mm) Standard stroke (mm) Standard Non-rotating Double rod 8 10 12 16 20 25 10, 25, 40, 50, 80, 100 100 100 400 10, 25, 40, 50, 80, 100, 125, 160, 200 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 200 200 1000 1000 500 Not available with air cushion. Other strokes available on request.
DYE DYF Red ST LED is flashing. (Diagnosis is activated) Red/green ST LED is flashing. Unit has failed Stop the operation and contact SMC. Red ST(I) LED is ON. (Diagnosis is activated) Check the parts with error by using the LED display or PLC or H.T. Re-wire the short-circuited part or check if the cable and input device are normal.
2.44 (kg) (Foot style 32) Additional weight 0.09 (kg/50 st) Cylinder stroke 600 (st) 2.44 + 0.09 x (600 500)/50 = 2.62 kg Accessory Mounting nut Rod end nut 30 30 d d D D C C H H B B Material: Carbon steel Material: Carbon steel B Part no.
ST () LED PLC H.T.ON/OFF DXE DXF ST () LED PLC ON/OFF ST / (60 ) -36No.EX-OMN0029CN-D EX600No. H.T. () LED PLC H.T. ON/OFF LED PLC () ON/OFF DYB / 3 H.T. ST () LED PLC H.T. ON/OFF LED PLC DYE DYF ST () ON/OFF ST / H.T. ST(I) () LED PLC H.T.ON/OFF ST(I) () LED PLC ON/OFF H.T. ST(0) () LED PLC 4 DME DMF H.T.
Bore stroke 32 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500 700 40 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500 800 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600 1200 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600 1200 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600, 700, 800 1400 100 25, 50, 80, 100, 125, 160, 200,
Green ST(M) LED is flashing. Analogue input unit displays error. Refer to Fault 5. Analogue output unit displays error. Refer to Fault 6. Analogue I/O unit displays error. Refer to Fault 7. Contact SMC if it does not recover after replacing the SI unit whose unit is broken. -32No.EX-OMS0027 SI unit Red ST(M) LED is flashing. Refer to Fault 8. Red ST(M) LED is ON.
Red ST(M) LED is flashing. (When diagnosis is activated) 8 (3)ON/OFF count of the valve has exceeded the set value. Red ST(M) LED is ON. SI unit has failed. Stop the operation and contact SMC. 9 Red/green ST(M) LED is flashing alternately. Connection between the units is defective. Confirm that there is no loose connection between the units and connect them correctly.
Cylinder tube shape for 0.75, 106 K M1 O-counter bore R depth A + Stroke E 0.13 [0.16] Note 1) 2 sides x 4 places (Inch) C Symbol Bore 1/8"st 1/4"st 3/8" to 4"st A Z W R Q P O N M2 M1 K J I H E D 075 (3/4") 106 (1-1/16") 150 (1-1/2") 200 (2") 250 (2-1/2") 0.31 0.36 0.46 1.25 0.56 #10-32UNF 1.56 0.06 0.25 0.86 1.22 0.15 0.25 0.19 0.15 1.31 0.38 #10-32UNF 0.50 0.70 0.52 1.56 0.88 5/16-24UNF
Set of nos. above @2, @3, @4 8-29-6 7 Dual Rod Cylinder: Basic Type Series CXS Dimensions: 6 ZZ (58.5 + ST) ST SS (45 + ST) 16 8 5.5 Z (10 + 1/2 ST) 2-3.4 through 2-6.5 counterbore depth 3.3 M3 x 0.5 x 5l (Hexagon socket head set screw) 14 1 2.75 13 3 3 OUT 1 MX 5.6 3.2 MTS 0.2 28 0.2 22.7 (16) 37 35 16 28 MY 6.3 5 CY M2.5 x 0.45 x 6l 6 (Hexagon socket headcap screw) M3 x 0.5 x 12.5l, M3
(The lock-up cylinder can operate at 50 to 200 mm/s.)
ST () LED PLC H.T. LED PLC DXE DXF ST () ON/OFF ON/OFF (73 ) -45No.EX-OMN0027CN-D EX600No. H.T. () LED PLC H.T. LED PLC ON/OFF DYB ON/OFF () 3 H.T. ST () LED PLC H.T. LED PLC ON/OFF DYE DYF ON/OFF ST () H.T. ST(I) () LED PLC H.T. LED PLC ST(I) () ON/OFF ON/OFF H.T. 4 DME DMF ST(0) () LED PLC H.T.
Please consult with SMC. 10 9 8 25 7 6 5 20 4 16 3 2 12 1 0 50 100 200 150 250 300 Stroke ST (mm) 550 Compact Cylinder: Standard Type Double Acting, Single Rod Series CQS 12, 16, 20, 25 How to Order B 20 D 30 CQS M9BW B D 20 30 CDQS With auto switch Made to Order Refer to page 552 for details.
+ 1.4 0 st + 1.5 0 st + 1.4 0 st + 1.5 0 Up to 1000 mm, Up to 1200 mm 20 to 63 CY Stroke length tolerance Up to 1000 mm, Up to 1500 mm 80, 100 Basic style, Axial foot style, Rod side flange style, Head side flange style, Clevis integrated style MQQ M JIS Symbol Double acting, Single rod Mounting RHC Standard Stroke MK(2) Standard stroke Long stroke Note) Bore size (mm) RS Q G 20 25, 50,