Install an air drier or aftercooler before the product. Caution (1) When the element becomes clogged at an early stage, please check the air quality.
Use it when it is necessary to remove water, but when air as dry as that from an air dryer is not necessary.
Move the product to an environment with little noise, turn ON the power supply. If there is no alarm, it was caused by noise. Please consult with SMC. Move the product to an environment with little noise, turn ON the power supply. If there is no alarm, it was caused by noise. Please consult with SMC. In the case the alarm cant be reset by above manner, repair is required.
Warning 1.Do not use in an atmosphere containing an inflammable gas or explosive gas. Use in such an atmosphere is likely to cause a fire or explosion. This system is not explosion-proof. 7.Keep dust, wire scraps and other extraneous material from getting inside the product. This may cause malfunction or damage. 8.
If any valves are used ensure that they do not restrict the flow, otherwise low flow may cause an alarm.
Please place an order separately. You are requested to connect it to an SI unit and a valve manifold. When using the output block only (valve manifold is unused.), place an order for an end plate (!1 EX9-EA03) separately for connection.
Air supply unit (optional) Oil felt seal Air Supply Unit (optional) Air can be supplied at the end of stroke to an actuator mounted on the slide table.
Please use an appropriate dryer to ensure dry air and prevent the valve lrom freezing. OThe double solenoid valve must be energized for at least 0.1 second o( more to enaurg proper operation.
Please use an appropriate dryer to ensure dry air and prevent the valve lrom freezing. OThe double solenoid valve must be energized for at least 0.1 second o( more to enaurg proper operation.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
Select an air be continued because the original lubricant applied filter with a filtration size of 5m or smaller. 3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. during manufacturing will be washed away.
Do not use an open tank. Sep W TW UW VW . ZW AW BW . Oct X TX UX VX . ZX AX BX . Nov y Ty Uy Vy . Zy Ay By . Normal When high head pump option selected Dec Z Tz UZ VZ . ZZ AZ BZ . 5 Installation Continued 5 Installation Continued 6 Operation Continued 7 Outline Dimensions (mm) 6.3.1 Level 1Settings HECR002 HECR002-A5-E(option) No.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
Cooling Capacity: 300 (28 kW), Thread: Rc, Option: K (w/Fluid Fill Port)
Cooling Capacity: 300 (28 kW), Thread: Rc, Option: AK (A + K)
Cooling Capacity: 300 (28 kW), Thread: Rc, Option: A (w/Caster Adjuster-foot)
Cooling Capacity: 300 (28 kW), Thread: F (G, w/Rc-G Conversion Fitting), Option: AKM (A + K + M)
Cooling Capacity: 28 kW, Thread: Rc, Option: w/Fluid Fill Port