15, 20, and 30 are the same as those of single type.
OPTION S SERIES 70 OPTION AS OPTION Q SERIES 20 & 30 SERIES 20 & 30 SERIES 70 OPTION AD OPTION AS OPTION AD AN CONNECTOR AUTOMOTIVE TERMINAL SINGLE STRAIN RELIEF CONNECTOR SUPPLIED WITH SJT LEADS AUTOMOTIVE TERMINAL SINGLE AUTOMOTIVE TERMINAL DOUBLE AUTOMOTIVE TERMINAL DOUBLE OPTION J J.I.C. HOUSING (SERIES 20 ONLY) When additional solenoid protection is required, Coast's J.I.C.
Remove the covers as shown in Figure (2) and make further adjustment by loosening the hexagon nut. 3. Various dimensions are indicated in Table (1). Never make an adjustment that exceeds the dimensions in the table, as it may cause an accident and/or damage.
D-m Bore size (mm) Auto switch models 20 32 40 to 100 D-F7m/J79 D-F7mV D-J79C D-F7mW/J79W D-F7mWV D-F7BAL/F7BAVL D-F79F/F7NTL D-A7m/A80 D-A73C/A80C D-A7mH/A80H D-A79W Refer to the table below for details on BBA2. When an additional D-M9mA(V)L is required, order stainless steel screw kit BBA2 or BQ2-012S as a set separately.
LEC-CN5-m To Parallel I/O connector Actuator cable*1 p. 178 Robotic cable LE-CE-m To SI To ENC 1 Can be included as an option. Refer to the How to Order page of the actuator.
100 2 x AS AT0.02 AQ0.02 Bottom 2 x AS AR MGC series 20 to 50 2 x AS MGC Series (mm) AT0.02 AQ0.02 Bore size (mm) AQ AR AS AT AU 20 25 32 40 50 +0.012 0 90 37.5 45 15 5H7 depth 6 +0.012 0 103 40 55 20 6H7 depth 8 +0.012 0 118 42.5 60 20 6H7 depth 8 +0.015 0 140 47.5 70 22 8H7 depth 11 AR Bottom 2 x AS +0.015 0 170 65 85 30 8H7 depth 11 AU0.02 MGQ series (mm) MGQ Series NA Bore size (mm)
Connect the signal cable and switch to the terminal as follows. (This wiring is an example.)
method: Mounting bolt for through-hole mounting style of CQ2WB is available as an option.
Mixed single and double wiring is available as an option.
Series CY1L Size: 6, 10, 15, 20, 25, 32, 40 To ensure a permanent path Stable operation is possible, even with an eccentric load, by using ball bushings. When smoother operation is required, even with an eccentric load. Series CY1H Size: 10, 15, 20, 25, 32 The use of a linear guide facilitates a large load, large moment and high precision.
~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC Material Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Courtesy of Steven Engineering, Inc. !
Wire the power supply/main circuit as shown below so that power is shut off and the servo-on command turned off as soon as an alarm occurs, a servo forced stop is made valid, or a PC or PLC...etc forced stop is made valid.
Standard stroke (mm) Bore size 12, 16 20, 25 Standard stroke 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 Double acting Action D Built-in Magnet Cylinder Model If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch.
Keep the lead wire length as short as possible.
Because sizes 10, 20, 30 and 50 have the table press fit into an angular type bearing, they cannot be disassembled. 211
20 30 40 50 51 100 200 10 10 20 30 40 50 51 100 200 Stroke (mm) Stroke (mm) 7 l = 50mm V = 400mm/s 8 l = 100mm V = 400mm/s 50 50 80 80 80 80 40 40 30 30 20 20 50 50 50 50 10 10 50 20 30 40 51 100 200 10 10 50 20 30 40 51 100 200 47 Series MGP Compact Guide Cylinder: Heavy Duty Guide Rod Type Operating Range when Used as Stopper 2000 l: Approx. 50mm l: Approx. 50mm MGPS80 1000 m m Weight
25 REAH15, 20, 25 REAH15, 20, 25 REAH15, 20 REAH15, 20 REAH25 REAH15, 20 REAH25 High Precision Guide Type REAH 0.08 Deflection (mm) Deflection (mm) Deflection (mm) Deflection (mm) 0.03 REAH25 0.02 0.06 0.02 0.04 0.01 0.01 0.02 Max.
Remove the covers as shown in Figure 2 and make further adjustment by loosening the hexagon nut. 3. Various dimensions are indicated in Table 1. Never make an adjustment that exceeds the dimensions in the table, as it may cause an accident and/or damage.