Cooling Capacity: 250 (25kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AKT (A + K + T)
Cooling Capacity: 250 (25kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: KT (K + T)
Cooling Capacity: 250 (25kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: ABK (A + B + K)
Cooling Capacity: 250 (25kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AT (A + T)
Cooling Capacity: 250 (25kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: T (High-pressure Pump Mounted)
Cooling Capacity: 250 (25kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AB1KM (A + B1 + K + M)
Cooling Capacity: 250 (25kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: KM (K + M)
Cooling Capacity: 250 (25kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AKMS (A + K + M + S)
Cooling Capacity: 250 (25kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: B (w/Earth Leakage Breaker)
Cooling Capacity: 250 (25kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: M (Applicable to DI Water Piping)
32, 40, 50, 63 124 AS3000-03 3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C.
(mm) Applicable cylinder bore size (mm) 4 6 8 10 12 AS-FPG AS-FPQ Clean performance Resin: PP Metal: Brass (electroless nickel plated) Resin: PP Metal: Stainless steel 304 M5 x 0.8 6, 10, 16, 20 AS121FP-M5 R 1/8 20, 25, 32 AS221FP-01 R 1/4 20, 25, 32, 40 AS221FP-02 R 3/8 40, 50, 63 AS321FP-03 10-AS-F 10-AS-FG R 1/2 63, 80, 100 AS421FP-04 Resin: PBT, POM Metal: Brass (electroless nickel plated
AQ Elbow type Metric size 04 06 08 10 4 6 8 10 ASV AK Control type Meter-out Meter-in 0 1 VCHC Port size ASR ASQ U01 Uni Uni Uni U02 U03 1 8 1 4 3 8 With One-touch fitting 635
filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, DUST PROOF FILTER HRSH250, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 0.8 lb
filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, PDB2 FOR HRSH250, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb
Please contact us for the latest version.sales@ocaire.com, NOISE FILTER HRSH250-A-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 0.8 lb
Please contact us for the latest version.sales@ocaire.com, FRONT PANEL FOR HRSH250-A, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb
the grill of the front panel allowing mounting and removal of the HRSÂ filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, SIDE PANEL L (FOR HRSH250
the grill of the front panel allowing mounting and removal of the HRSÂ filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, FRONT PANEL L FOR HRSH250
Please contact us for the latest version.sales@ocaire.com, HEAT EXCHANGER ASSY HRSH250-A, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb