Top port An air cushion has been added to the compact guide cylinder to suppress vibration and noise at the stroke end. It can absorb nearly three times as much kinetic energy as a rubber bumper. Stroke Variations D1. Auto switch mounting 4.
Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause malfunction of pneumatic equipment such as rotary actuators. Therefore, take appropriate measures to ensure air quality, such as by providing an aftercooler, air dryer, or water separator. 4.
29 6 A B NN x M6 x 1 Tapped through hole 5H9 depth 5 +0.030 0 HA GA Section AA Section BB (mm) ZZ 108 108 108 118 136 169 226 254 282 M 94 94 94 104 122 155 212 240 268 Z 92.5 92.5 92.5 102.5 120.5 153.5 210.5 238.5 266.5 K 31 41 51 61 71 96 121 146 171 J 46 46 46 56 72 100 155 190 215 I 16 16 16 16 18 23 25 18 21 NN 2 2 2 2 3 3 4 4 4 H 46 46 46 56 56 56 59 62 G 22 22 22 22 17 18 37 56
In case of high piston speed, the operating time of the load can be extended by using an auto switch (D-F7NT) with built-in OFF delay timer (approx. 200ms). 4. Keep wiring as short as possible.
Do not use the product in an environment where the product is constantly exposed to water or oil splashes. If the product is to be used in an environment containing oils or chemicals such as coolant or cleaning solvent, it may be adversely affected (damage, malfunction, or hardening of the lead wires). Do not use in an area where surges are generated.
Cannot be used as an emergency shutoff valve, etc. This product is not designed for use as an emergency shutoff valve. If the valve is used in this type of system, other reliable safety assurance measures should also be adopted. 3.
Do not use the product in an enclosed space as ozone and nitrogen oxides exist, even though in marginal quantities. 3) Environments to avoid Never use or store under the following conditions. These may cause an electric shock, fire, etc. a. Use in the environment which ambient temperature is out of the product specification. b.
As a result, the inside of the bowl q, is shut off from the outside air. Therefore, even if there is an accumulation of condensate in the bowl q, it will not drain out.
Remove the covers as shown in Figure (2) and make further adjustment by loosening the hexagon nut. 3. Various dimensions are indicated in Table (1). Never make an adjustment that exceeds the dimensions in the table, as it may cause an accident and/or damage.
It turns OFF when an alarm occurs or when JOG movement takes place.
Perform inspections on a regular basis as necessary, such as at the beginning of an operation, to make sure that the mechanical valve operates properly. Failure to observe this precaution could lead to unsafe operation, such as unintended operation or malfunction.
Note 9) The copper and fluorine-free specification is available as a standard product.
Do not use the product in an environment where the product is constantly exposed to water or oil splashes. If the product is to be used in an environment containing oils or chemicals such as coolant or cleaning solvent, it may be adversely affected (damage, malfunction, or hardening of the lead wires). Do not use in an area where surges are generated.
As a result, the inside of the bowl G, is shut off from the outside air. Therefore, even if there is an accumulation of condensate in the bowl G, it will not drain out.
When magnetic substances such as iron (including flange brackets) are in close proximity to an auto switch cylinder (auto switch mounting side), be sure to provide a clearance between the magnetic substance and the cylinder body as shown in the drawing below.
In order to further improve stopping accuracy, the time from the stop signal to the operation of the lock should be shortened as much as possible. To accomplish this, use a device such as a highly responsive electric control circuit or solenoid valve driven by direct current, and place the solenoid valve as close as possible to the cylinder.