Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC)
Cooling Capacity: 150, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
Cooling Capacity: 38 kW, Cooling Method: Air-cooled Refrigeration, Pipe Thread: NPT, with Rc-NPT Conversion Fitting, Power Supply: 50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC, Option: -
Cooling Capacity: 150, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: -, UL Certification: -, Option 2: -
Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: -, UL Certification: -, Option 2: -
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: -
Please use an appropriate dryer to ensure dry air and prevent the valve lrom freezing. OThe double solenoid valve must be energized for at least 0.1 second o( more to enaurg proper operation.
Please use an appropriate dryer to ensure dry air and prevent the valve lrom freezing. OThe double solenoid valve must be energized for at least 0.1 second o( more to enaurg proper operation.
Note) 4 6 8 10 12 23 04 06 08 10 12 3.2 TMH-23J TMH-04J TMH-06J ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F AK TMH-06 TMH-08 ASS TMH-10 TMH-12 Applicable tubing Inch Size ASR Note) Mounting bracket is not available. This is an application example. Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.
Note) 4 6 8 10 12 23 04 06 08 10 12 3.2 TMH-23J TMH-04J TMH-06J ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F AK TMH-06 TMH-08 ASS TMH-10 TMH-12 Applicable tubing Inch Size ASR Note) Mounting bracket is not available. This is an application example. Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F (G, with Rc-G Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+K
Cooling Capacity: 100, Thread Type: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: A + K, UL Certification: -, Option 2: -
Cooling Capacity: 10 kW, Cooling Method: Water-cooled, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460-480 VAC (60 Hz)], Option: w/Caster Adjuster-foot and Fluid Fill Port
Cooling Capacity: 15 kW, Cooling Method: Water-cooled, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460-480 VAC (60 Hz)], Option: w/Caster Adjuster-foot and Fluid Fill Port
Do not use in an atmosphere containing an inflammable gas or explosive gas. Use in such an atmosphere is likely to cause a fire or explosion. This system is not explosion-proof. Caution 1. Select the proper type of enclosure according to the environment of operation.
The pre-load type requires an air-hydro converter (Series CCT).
It may cause an accident or malfunction.
/Flange Rod end width across flats 10 10 21 21 46 46 Data Part no.