Series TW coaxial tubing is available in 20 meter rolls. The TW is a soft nylon material. The outer tube is white and the inner tube is yellow. Used in SMCs coaxial air tubing system, it is possible to pipe pneumatic equipment using only one tube., COAXIAL TUBING, YELLOW/WHITE, CONNECTORS, TW COAXIAL TUBING, LX, TW 12MM, 3.70411 lb
Series TW coaxial tubing is available in 20 meter rolls. The TW is a soft nylon material. The outer tube is white and the inner tube is yellow. Used in SMC's coaxial air tubing system, it is possible to pipe pneumatic equipment using only one tube., COAXIAL TUBING, YELLOW/WHITE, CONNECTORS, TW COAXIAL TUBING, 1X, TW OTHER SIZE RATING, 1.92459 lb
Series TW coaxial tubing is available in 20 meter rolls. The TW is a soft nylon material. The outer tube is white and the inner tube is yellow. Used in SMC's coaxial air tubing system, it is possible to pipe pneumatic equipment using only one tube., Electronic delivery, TRAINING EQUIPMENT, H25, 0.00000 lb
Series TW coaxial tubing is available in 20 meter rolls. The TW is a soft nylon material. The outer tube is white and the inner tube is yellow. Used in SMC's coaxial air tubing system, it is possible to pipe pneumatic equipment using only one tube.
, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024, HRS030
1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024, HRS030
, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024, HRS030
1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024, HRS030
Applicable bore (mm) Round type A D L N R W MM Flat type Applicable bore (mm) TDH10 TC TH TK TN TT TU TV TW TX TY TZ Part no. CJ-CF006 CJ-CR006 6 6 8 11 5 8 6 M3 x 0.5 10 CJ-T010B CJ-CF010 CJ-CR010 3.3 10 8 10 13 6 10 8 M4 x 0.7 29 18 2 9 40 22 32 12 8 4.5 3.1 +0.048 0 16 CJ-T016B CJ-CF016 CJ-CR016 5 16 10 12 15 7 12 10 M5 x 0.8 35 20 14 48 28 38 16 10 5.5 6.4 2.3 +0.048 0 6-3-11
16 No.VQZ100V-OMT0001 Revision history TW 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2008 SMC Corporation All Rights Reserved No.VQZ100V-OMT0001
Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)
Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc
Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)
Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc
Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 2,600/3,200 W (50/60 Hz), Piping thread type: Rc, Optional specifications: None
Type: -, Cooling Method: -, Cooling Capacity: 2,600/3,200 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: None
Type: -, Cooling Method: -, Cooling Capacity: 2,600/3,200 W (50/60 Hz), Piping thread type: Rc, Optional specifications: None
Type: -, Cooling Method: -, Cooling Capacity: 2,600/3,200 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: None
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.