Cooling Capacity: 012 [1000/1200 W (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: Applicabe to DI Water Piping, Option 2: -
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: DM + T1, Option 2: -
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: None, Option 2: -
Cooling Capacity: -, Cooling Method: -, Pipe Thread: -, Option 1: -, Option 2: -
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: Applicabe to DI Water Piping, Option 2: No Flow Sensor, Water Leakage Sensor, Particle Filter, Bypass Valve or Retaining Clip
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: Applicabe to DI Water Piping, Option 2: -
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: Automatic Water Supply Function
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: J + M
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: M + T
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: High-pressure Pump
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + J + M + T
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: Earth Leakage Breaker
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: J + T
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + M
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, END LOCK, ACTUATOR, CBA1/CBA2 TIE-ROD CYL END LOCK, SC, CBA1 100MM OTHERS (COMBO), .00000 lb
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)