When a longer DIN rail is desired than the specified stations, specify the station number to be required. (20 stations maximum) D U D side U side 2 to 10 stations 20 20 stations This also includes the number of b l a n k i n g plate assembly.
When a longer DIN rail is desired than the specified stations, specify the station number to be required. (20 stations maximum) D U D side U side 2 to 10 stations 20 20 stations This also includes the number of b l a n k i n g plate assembly.
REA CDU Double Acting, Single Rod (mm) W B A W B D-M9A D-M9AV D-A9, D-A9V D-M9, D-M9W D-M9V, D-M9WV Bore size (mm) REB A B W A B W A B W A 10 16 20 25 32 12.5 3.5 (-1.5)1 16.5 7.5 2.5 16.5 7.5 0.5 16.5 7.5 4.5 16.5 7.5 2.5 REC (-2)0.5 16 4 20 8 1.5 20 8 -0.5 20 8 3.5 20 8 1.5 (-4)-1.5 20 6 24 10 0 24 10 -2 24 10 2 24 10 0 CY (-5.5)-3 22.5 7 26.5 11 -1.5 26.5 11 -3.5 26.5 11 0.5 26.5 11 -1.5
C85 Series: 8, 10, 12, 16 [cm] 10.0 Mounting Applicable maximum stroke according to buckling strength Operating pressure [MPa] Nominal symbol C85 Support bracket nominal symbol and schematic diagram 8 10 12 16 20 25 Foot: M Rod flange: G Head flange: G Lateral load applied to the rod end fR [N] 0.3 26 38 18 36 24 48 M 1.0 G G N U U M 0.5 19 29 14 27 18 36 W W W C8516 Rod (side) 0.7 16 23
S U S U S U S w U S AXT100-1-J 20 Note 3) U S e r AXT100-1-F Note 3) AXT100-1-GU20 Note 1) Suffix -XP to the end of the part number for dust-protected SI unit.
S U S U S U S w U S AXT100-1-J 20 Note 3) U S e r AXT100-1-F Note 3) AXT100-1-GU20 Note 1) Suffix -XP to the end of the part number for dust-protected SI unit.
Form w 1 Material e Buffer spec. r Buffer stroke t Vacuum inlet A J 3 30 17 M6 x 0.75 10 8 5 4 6 37 20 14 N S U F GN GS ZP3 Y 015 02 035 U B3 K 3 34 17 M8 x 0.75 11 10 7 6 6 40.5 20 14.5 13 B Dimensions Per Vacuum Inlet: One-touch Fitting 7 Model H J K Fitting part min. hole size Fitting part no. Vacuum inlet direction q Pad dia.
1 u !0 o t r e w y (B) (A) 2 4 (B) (A) 2 4 4(A) 3 5 1 3 5 1 (EB) (P) (EA) (EB) (P) (EA) 2(B) i 5(EA)/3(EB) 1(P) 2 position double 2 position double 2 position double with back pressure check valve t r e w y q !1 u !
4 u u !2 !3 i e !5 r t w q y !6 !
EX124D-SMJ1] Note 1) U S U S e w AXT100-1-P Note 2) U S U S SYJ AXT100-1-F Note 2) Note 1) Dust-tight, Water-jet-proof (IP65) Note 2) Top entry connector for FU, PU while side entry connector for FS, PS.
P C Regeneration option U C V Servo motor power (U) Servo motor power (V) Servo motor power (W) U V W W Connect to motor cable (U, V, W).
W NA Enclosure IP67 Refer to Note 1) of the w SI unit specifications. w q e r y t u i q Series t P, E port location r Valve stations 1 2 3 U D B For 32-output SI unit 10-SV1000 10-SV2000 10-SV3000 U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 20 stations) Symbol 02 Stations Note 2 stations Double wiring Note 1) w SI unit specifications 16 02 16 stations y SUP/EXH block
Dynamic moment U: Maximum speed U Calculation examples Operating conditions W Cylinder: REAH15 Mounting: Horizontal wall mounting Maximum speed: U = 300 [mm/s ] Load weight: W = 1 [kg] (excluding weight of arm section) L1 = 200 [mm] L2 = 200 [mm] L2 L1 Item Load factor n Note 1. Maximum load weight W 1 = W/Wmax = 1/9 = 0.111 L2 Review W. L1 2.
Mounting 20 Tie-rod base 20 stations Direct mount DIN rail mount (with DIN rail) DIN rail mount (without DIN rail) Nil D D0 D3 SS5V W 1 05 U 10CD Note) When a DIN rail longer than the specified stations is required. (Specify a rail longer than the standard length.) Cassette base For 3 stations SS5V W 05 16CD 1 U ... ...
P C Regeneration option U C V Servo motor power (U) Servo motor power (V) Servo motor power (W) U V W W Connect to motor cable (U, V, W) Control Circuit Power Supply Connector: CNP2 Accessory 24V Terminal name Function Details 0V 24 V side of the control circuit power supply (24 VDC) which supplies the driver.
D77 Free Mount Type Rotary Actuator With Angle Adjuster/Vane Type CRBU2WU Series Size: 10, 15, 20, 30, 40 RoHS How to Order CRBU2 S 20 180 U Z W With auto switch CDRBU2 S 20 180 L U Z M9B W q w e r t y u i o !
Connection of driver and servo motor The servo motor power supply terminals (U, V, W) of the driver should match in phase with the power input terminals (U, V, W) of the servo motor. Driver Servo amplifier Servo motor U U V V M W W The power supplied to the driver should not be connected to the servo motor power supply terminals (U, V, W).
CBM2-20-PS CBM2-25-PS CBM2-32-PS CBM2-40-PS 10 Lock bushing Copper alloy With lock at double ends 11 Lock spring Stainless steel Kit no. CBM2-20-PS-W CBM2-25-PS-W CBM2-32-PS-W CBM2-40-PS-W 12 Bumper Urethane Seal kit includes @6 and @7. Order the seal kit, based on each bore size. (Except #3.) Seal kit includes a grease pack (10 g).
MGC series 20 to 50 MGC Series (mm) C port SZ + Stroke B Cushion valve (Width across flats WH) Front mounting flange Bore size (mm) GC GD SA SB W 1 W 2 A, B port A port W 2 W 1 A 20 25 32 40 50 30 30 21 9 50 87 30 30 C port D port 21 9 50 87 B port W 2 W 1 10 A' 25 30 23 9 52 91 20 20 24 8 59 99 Cushion valve (Width across flats WH) D port ZZ + Stroke A + Stroke B SB + Stroke B SA + Stroke