Panel Mounting Style CJPB M5 x 0.8 Exhaust port 5: C0.5 10, 15: C1 Hose nipple Refer to page 6-2-13. Mounting dimensions of CJ-5H-6. ( ) denotes the dimensions of CJ-5H-4. Rod end nut (Refer to page 6-2-13.)

KJL04-C1-N Unit specifications Nil M P With unit switching function Note 1) SI unit only Note 2) !1 Filter element (10 pcs. in 1 set) With unit switching function (Initial value psi) Note 1) Note 1) The unit switching function is not available in Japan due to a new measurement law.

K V 1 10 XLA S P1P2 XL XL Conductances combined When each of the separate conductances are given as C1, C2 and Cn, the composite conductance C is expressed as: C=1/(1/C1+1/C2++1/Cn) when in series, and C=C1+C2++Cn, when in parallel.

16.5 Rc1/8 pilot (12) port G1/4, Rc1/4 IN(1) port 15 2 x 6 (for M5 mounting) G1/4, Rc1/4 OUT(2) port 48 6 22 22 6 25 25 43 15 15 M5 leakage detection port 23 30 22 Part number for sub-base VCC12-S02 02F [Rc1/4] [G1/4] 60 0.5 to 2 Sub-base material is aluminum + hard anodized containing PTFE.

#B4 #B3 #B2 #B1 #A4 #A3 #A2 #A1 connection diagnosis 32 point 9 COM_D COM_C COM_B COM_A switch diagnosis -: Unused 23 No.EX-OMS0014-A Diagnostic data Diagnostic information Input data Offset Meaning MSB LSB MSB LSB (INT) 15 8 7 0 8 #D4 #D3 #D2 #D1 #C4 #C3 #C2 #C1 #B4 #B3 #B2 #B1 #A4 #A3 #A2 #A1 Slave condition Port 9 Error code COM_D COM_C COM_B COM_A diagnosis/ Error code < Slave condition

Please refer to page of Best Pneumatics Vol. 7. 12 2-M5 x 0.8 Auto switch Lead wire min. bending radius 10 H thread effective depth C 2 x 4-OB counterbore depth RB 2 x 4-OA effective depth RA Note 1) Q F 16 I 4-N through D M E T Plain washer K B + Stroke L M A + Stroke E 20, 25 Rod end male thread H1 Rod end nut Note 2) C1 X L1 Rod End Male Thread Bore size (mm) 12 16 20 25 (mm) C1 9 10 12

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Q F 16 I 4-N through D M E T Plain washer K B + Stroke L M A + Stroke E 20, 25 Rod end male thread H1 Rod end nut Note 2) C1 X L1 Rod End Male Thread Bore size (mm) 12 16 20 25 (mm) C1 9 10 12 15 H1 M5 x 0.8 M6 x 1.0 L1 14 15.5 18.5 22.5 X 10.5 12 14

Rod end male thread Bore(mm) 12 16 20 25 L1 14 15.5 18.5 22.5 X 10.5 12 14 17.5 C1 9 10 12 15 H1 M5 X 0.8 M6 X 1.0 M8 X 1.25 M10 X 1.25 Basic Bore (mm) Stroke range (mm) A 25.5 25.5 29 32.5 W/o auto switch With auto switch (All dimension are common except "A" and "B").

VDW 2 0 1 C1 1 VC OUT (2) VDW Series Lead wire length 1 2 3 10 20, 200 30, 300 300 mm 600 mm Nil L1 (1) IN 2 Port Valve VQ Note) Note) Type L1 is optional.

VCC12(D)-00 38.80.1 230.1 Leakage detection port 16.50.1 1.2 to 2 hole 3.8 hole Pilot port IN port 4 hole 1.2 hole R0.2 30 R0.2 OUT port 210.05 M26 x 1.5 21.60.05 240.05 200.05 C1 30 30 2.5 8.5 330.1 40.80.1 450.1 Recommended surface roughness of inner surface where the valve is inserted is Rz6.3.

alloy Resin Plate Magnet holder Aluminum alloy Anodized 17 4 Rare earth magnet Aluminum alloy Anodized 18 5 Tube Magnet With home position switch With home position switch With magnet 6 Rod assembly Sensor plate 19 Mild steel 7 Stopper A With bumper 20 Photo micro sensor Stopper B 8 Motor cover 21 Resin Direct acting guide (block, rail) Rolled screw (shaft only) 9 Plug A 22 Plug B 23

Air operated K3 Air operated C1 N.C. C2 Air operated Digital vacuum switch specifications (D1, D2, D3) C3 N.O. C4 Double SOL.

H1 X 10 23.5 10.5 15.5 M5 x 0.8 16 26.5 11.5 16.5 M6 x 1.0 C1 20 28.5 13.5 18.5 M8 x 1.25 Rod end thread adapter X 25 34.5 16.5 M10 x 1.25 22.5 L1 30 40.5 22.5 M14 x 1.5 28.5 40 40.5 22.5 M14 x 1.5 28.5 Refer to page 1180 for details regarding the rod end thread adapter and the rod end nut. 1178 Compact Low Friction Cylinder Metal Seal Series MQQ (mm) Foot type: MQQLL 10, 16, 20 Special

10 to 50 63.5 17.5 depth 13.5 80 73.5 63.5 21 25 98 12.5 M16 x 2.0 132 6 22 10 77 11 3/8 16 112.5 57.5 26 63.5 75, 100 73.5 63 10 to 50 75 17.5 depth 13.5 100 85 73 27 30 117 13 M20 x 2.5 156 6.5 27 12 94 11 3/8 23 132.5 67.5 26 73 75, 100 85 7

With rod end male thread: MQQ-DM Rod end nut H1 (mm) Bore size (mm) L1 C1 H1 X 10 23.5 10.5 M5 x 0.8 15.5 16 26.5 11.5 M6 x 1.0 16.5 C1 20 28.5 13.5 M8 x 1.25 18.5 Rod end thread adapter X 25 34.5 16.5 M10 x 1.25 22.5 L1 30 40.5 22.5 M14 x 1.5 28.5 40 40.5 22.5 M14 x 1.5 28.5 Refer to page 9 for details regarding the rod end thread adapter and the rod end nut. 5 Compact Low Friction Cylinder

When MBR is set for the CN1-23 pin, turning ABSM on will change the CN1-23 pin to ABSB1 (ABS transmission data bit 1). Therefore, configure an external sequence to generate the electromagnetic lock torque as soon as ABSM and MBR turn off.

Color of release button Socket KDM10S-23 KDM10S-04 KDM10S-06 KDM10S-08 KDM20S-23 KDM20S-04 KDM20S-06 KDM20S-08 3.2 4 6 KDM10P-23 KDM10P-04 KDM10P-06 KDM10P-08 KDM20P-23 KDM20P-04 KDM20P-06 KDM20P-08 10 8 3.2 Blue 4 6 8 20 Mixed Sizes of Plug Connectors and Socket Connectors Panel mounting qLoosen (4) screws for bracket on the socket side using a Phillips screwdriver (JIS nominal No.2) until

Calculation: Example) CJ2L10-45Z OBasic weight 22 (10) OAdditional weight 4/15 stroke OCylinder stroke 45 stroke OMounting bracket weight 8 (Axial foot) 22 + 4/15 x 45 + 8 = 42 g Clevis pin 1 3 1 3 One-touch connecting pin for double clevis 2 4 Single knuckle joint 17 23 17 23 Double knuckle joint (including knuckle pin) 25 21 25 21 Accessories Double knuckle joint (With one-touch connecting