SMC Corporation of America
Elite Part Number Search
Search Results "CXSM20-90-Y7PW"

Y7NW Y7NWV 5 V 12 V Diagnostic indication (2 color indication) IC circuit Y7PW Y7PWV Refer to page 8-30-1 for detailed auto switch specifications.

As a rough guide, tighten the screw an additional 90 after feeling a tight resistance. As a rule, it should be turned about 90 beyond the point at which tightening can be felt. 0.5 0.2 0.3 MHL2-20D 0.5 0.2 0.2 MHC MHL2-25D 0.2 0.1 0.2 MHL2-32D 0.4 0.4 0.7 MHT MHL2-40D 0.2 0.4 0.7 MHY MHW MRHQ Misc.

MY1CW MY1MW m 200 200 190 (kg) (kg) 190 (2100) (2100) (2100) (2100) 180 180 l 170 170 160 160 150 150 140 140 m l (2400) (2400) (2400) (2400) (2400) (2400) 130 130 (1800) (1800) (1800) (1800) m 120 120 Weight (m) Weight (m) 110 110 MY1MW63 MY1MW63 MY1MW63 100 100 (2000) (2000) (2000) (2000) (2000) (2000) l l 90 90 (1500) (1500) (1500) (1500) MY1CW63 MY1CW63 80 80 MY1MW50 MY1MW50 MY1MW50 Caution

5 . , ' , . i u , , MGQbll2 Slide bearing 0.24 0.24 o.32 0.35 0.39 MGOLI2 Ball bush bearing o.23 0.26 0.29 0.35 0.38 16 vepr,lrol Slide bearing 0.36 o.41 o.47 0.52 0.57 vcbr-ro Ball bush bearing 0.3s o.3s o.44 o.52 o.57 n MGOM20 Slide bearing 0.56 0.63 0.70 o.77 0.s6 1.10 MGOt20 Ball bush bearing 0.54 o.60 0.70 o.90 1.04 ,' .is MGOM25.

J 98 152 192 Model MHL2-16D MHL2-16D1 MHL2-16D2 45 75 95 60 90 110 28 58 78 68 110 130 98 170 210 128 200 240 26 50 70 Notes) J dimension is at fully closed position.

32 32 43 43 64 64 78 39 43 49 59 71 82 106 +0.058 0 +0.058 0 129 151 185 208 237 263 298 10 10 14 14 22 22 25 33 33 45 45 65 65 75 MB-B03 +0.070 0 MB-B05 +0.070 0 +0.084 0 +0.084 0 +0.084 0 MB-B08 MB-B12 B Rotation 90 Bore size (mm) A B A + B + 90 20 25 32, 40 50, 63 80 35 30 30 35 30 50 50 50 50 35 175 170 170 175 155 A MGJ MGP Clevis Pin MGQ 2 x d Dd9 d Note) Cotter pin Bore size (mm)

CAT.ES20-178 A Smooth Cylinder Minimum 0.01 to 0.03 MPa operating pressure Minimum Minimum 0.01 to 0.03 MPa operating pressure 0.04 Minimum operating pressure MPa 12 16 0.03 20 25 32 40 0.02 50 63 80 100 0.01 0 0 10 20 30 40 60 50 70 80 90 100 Bore size mm (Measurement based on JIS B8377) Series CQSY/CQ2Y/CM2Y/CG1Y/CA2Y 12 to 25 32 to 100 20 to 40 20 to 100 40 to 100 Stable operation possible

Rubber cap wManual release lock type Push the M/O knob and turn it 90 counterclockwise. The lock disengages when the mark on the cap is aligned with the OFF mark on the M/O knob (and the lock will remain disengaged). To engage the lock, push the M/O knob all the way in and turn it 90 clockwise to align the mark on the cap with the ON mark on the M/O knob.

Auto switch model Lead wire length (m) 0.5 (Nil) 3 (L) 5 (Z) Load voltage Pre-wired connector Special function Type Indicator light Wiring (Output) Electrical entry Applicable load In-line AC Perpendicular DC Y59A Y7P Y59B Y7NW Y7PW Y7BW Y7BA Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 3-wire (NPN) 5 V, 12 V IC circuit 3-wire (PNP) Reed auto switch Solid state auto switch 12 V 2-wire Relay, PLC

Input circuit To operate the controller, use a power supply with the following specifications: 90 to 110 VAC, 50/60 Hz, and 21.6 to 26.4 VDC, 0.4 A or higher. The voltage and the amperage capacity of the switch or the PLC to be connected are 24 VDC, 10 mA or higher. Internal circuit RE A B REC 3. Output circuit CX There are two outputs, the NPN open collector and the PNP open collector.

(When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).

1 Smooth Cylinder CQSY/CQ2Y/CM2Y/CG1Y/CA2Y 12 to 25 32 to 100 20 to 40 20 to 100 40 to 100 RE A B Minimum 0.01 to 0.03 MPa operating pressure Minimum Minimum 0.01 to 0.03 MPa operating pressure REC CX 0.04 Minimum operating pressure MPa CY 12 16 0.03 MQQ M 20 25 32 40 0.02 RHC 50 63 80 100 0.01 MK(2) 0 0 10 20 30 40 60 50 70 80 90 100 RS Q G Bore size mm RS H A (Measurement based on JIS B8377

Input circuit To operate the controller, use a power supply with the following specifications: 90 to 110 VAC, 50/60 Hz, and 21.6 to 26.4 VDC, 0.4 A or higher. The voltage and the amperage capacity of the switch or the PLC to be connected are 24 VDC, 10 mA or higher. Internal circuit RE A B REC 3. Output circuit CX There are two outputs, the NPN open collector and the PNP open collector.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 20 25 32 40 0.02 RHC 50 63 80 100 0.01 MK(2) 0 0 10 20 30 40 60 50 70 80 90 100 RS Q G Bore size mm RS H A (Measurement based on JIS B8377) RZQ MI W S CEP1 Stable operation possible even at a low speed of 5 mm/s (Measurement based on JIS B 8377) Sliding

As a guide, it should be turned about 90 past the point at which tightening Tighten M2.5 screws with a torque of about 0.5 to 0.7 Nm, and M3 screws with a torque of about 0.5 to 0.7 Nm Inserting Direction for Mounting Auto switches can only be inserted from the head side. Inserting Direction for Mounting Auto switches can only be inserted from the head side.

As a rule, it should be turned about 90 past the point at which tightening can be felt. Slotted set screw (M2.5 x 4l) (included) Flat head watchmakers screwdriver Auto switch Auto switch Auto switch mounting surface Magnetic substances such as an iron plate should be separated at least 15mm away from auto switch mounting surface.

External gripping force Internal gripping force MHS2-32D MHS2-32D 150 150 Pressure 0.6MPa Pressure 0.6MPa 120 120 0.5MPa 0.5MPa Gripping force N Gripping force N 0.4MPa 0.4MPa 90 90 0.3MPa 0.3MPa 60 60 0.2MPa 0.2MPa F 30 30 0.1MPa 0.1MPa 0 0 10 10 20 20 30 30 40 40 50 50 F Gripping point L mm Gripping point L mm MHS2-40D MHS2-40D 250 250 Pressure 0.6MPa Pressure 0.6MPa 200 200 External gripping

As a rule, it should be turned about 90 past the point at which tightening can be felt. Slotted set screw (M2.5 x 4l) (included) Flat head watchmakers screwdriver Auto switch Auto switch Auto switch mounting surface Magnetic substances such as an iron plate should be separated at least 15mm away from auto switch mounting surface.