SMC Corporation of America
Elite Part Number Search
Search Results "CRP10-S1-AP-K"

Allowable Lateral Load on the Rod End Model Allowable lateral load on the rod end [N] LEPY6 (Basic) 0.50 F LEPY10 (Basic) 1.0 LEPY10L (Compact) 1.0 377 Step Motor (Servo/24 VDC) Electric Actuator Miniature Rod Type LEPY Series LEPY6, 10 How to Order LEPY 10 K 50 1 1 R 6N q w e r t y u i o !

P4 is selected by the ON/OFF combination of S1 and S2.

LC1-1-S1 PC-98 (MS-DOS) LC1-1-W1 (Windows 95 Japanese) LC1-1-W2 (Windows 95 English) and LC1-1-R (dedicated communication cable) (Refer to pages 80, 81, and 85.)

S H J M G A A (mm) Model A 189 198 B 66 79 C 2 2 D 11 11 E 55 75 F 41 52 G 63 68 H 20 20 J Max. 5 Max. 5 K L XLDQ-40 XLDQ-50 65 70 143 153 474 XLAQ/XLDQ Series Glossary of Terms 2 Shaft Sealing Method 1 Seal Materials Bellows Bellows offer cleaner sealing with reduced particle generation and less outgassing.

Flat finger [3] 4 x MM thread depth L Thread for mounting attachment K J A A D G B D B K J F C S W O (mm) Weight (g) F G Open Closed 2 2.5 3 4 L MM J K D C B Model A W MHZ2-10D3 1), 2) 11221122112211220 -0.05 0 -0.05 0 -0.05 0 -0.05 +0.5 +0.3 +0.5 +0.3 +0.5 +0.3 +0.5 +0.3 +0.025 0 +0.025 0 +0.025 0 +0.030 0 +2.2 0 +2.2 0 +2.3 0 +2.5 0 60 125 250 450 5 6 8 10 M2.5 x 0.45 M3 x 0.5 M4 x 0.7

Series VQ1000 Body Ported Plug-in Unit: Flip Type How to Order Manifold VV5Q1 N S1 F 3 08 Option Series VQ1000 Kit type None DIN rail mounting style Special wiring specifications (Except double wiring) Nil D (2) Manifold K (3) 3 Plug-in unit/Flip With name plate Built-in silencer, direct exhaust N S (4) Stations When two or more symbols are specified, indicate them alphabetically.

EXH port P1 LED level meter SUP port Sensor S1 S3 Red ON: Output OFF Green ON: Output ON S2 S4 + P2 Redq Detection port Below set position Large clearance S1, S2: Fix orifice S3: Variable orifice (adjusted by setting dial) S4: Detection nozzle Redw BEST POSITION Set position Greenq In a bridge circuit as in the figure above, a detection gap is applied to the detection nozzle (S4) while the

Silver (S1) Solid yellow (Y1) Clear yellow (Y2) Neon yellow (Y3) Clear orange (YR1) Neon orange (YR2) Nominal size (inch) 1 4 " 3 16" 1 8 " 3 8 " 1 2 " 5 32" 5 16" 3. The value of the minimum bending radius is measured at the temperature of 20C as shown in the figure below.

Spacer with Bracket Piping Adapter: 3/8, 1/2 J K D A piping adapter allows installation/removal of the component without removing the piping and thus makes maintenance easier. F H Port size G E E Center of F.R.L. body Center of F.R.L. body B B C D A Part no.

Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)

Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: (None 75 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)

Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: (None), Exhaust Solenoid Valve: V (V124-5LU-M5)

Controller Mounting: Screw Mounting, Cable Length: 1 m, Inlet Port Silencer: ANB1-01, 55 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: V124-5LU-M5

Controller Mounting: Screw Mounting, Cable Length: 1 m, Inlet Port Silencer: (None 75 dB), Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: V124-5LU-M5

Controller Mounting: Screw Mounting, Cable Length: 1 m, Inlet Port Silencer: ANB1-01, 55 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: (None), Exhaust Solenoid Valve: V124-5LU-M5

Refer to the operation manual for used equipment for details. -57- Pr.2 No. of pulse(s) per rotation(AP) Set the number of pulses required for a complete rotation of the motor shaft. If you are using the LECSS2-T, set the value given as the "resolution per servomotor rotation" in the speed/position detector specifications.

(If m otor option is with lock, lo ck ca ble is also include d.) 200 to 230 LECSC2-S C2 S1 LECSS1S 100 to 120 *6 The standa rd direction of each c a ble is shaft side(A)..

Vs: Power supply 24VDC 12 to 15VDC One of the preset pressures P1 through P4 is selected by the ON/OFF combination of S1 and S2. S1 S2 Preset pressure OFF OFF P1 ON OFF P2 OFF ON P3 ON ON P4 For safety reasons, it is recommended that one of the preset pressures be set to 0MPa.

Note 1) 25P Note 1) 26P 20P Side entry Side entry Side entry Connector entry direction Connector entry direction Connector entry direction P. 523 P. 527 P. 531 P. 535 Top entry Side entry Top entry Top entry Side entry Side entry Without cable Without cable Without cable With cable (1.5 m) With cable (3 m) With cable (5 m) Without cable S0 S1 S2 S3 U0 U1 U2 U3 S0 S1 S2 S3 0 1 2 3 U0 U1 U2

Note 1) 25P Note 1) 26P 20P Side entry Side entry Side entry Connector entry direction Connector entry direction Connector entry direction P. 523 P. 527 P. 531 P. 535 Top entry Side entry Top entry Top entry Side entry Side entry Without cable Without cable Without cable With cable (1.5 m) With cable (3 m) With cable (5 m) Without cable S0 S1 S2 S3 U0 U1 U2 U3 S0 S1 S2 S3 0 1 2 3 U0 U1 U2