A0.2 D (mm) MGPM MGPL/A Hexagon socket head cap screw 50 56 72 82 98 106 130 142 180 210 Bore size (mm) A (mm) B (mm) C (mm) M4 x 0.7 M5 x 0.8 M5 x 0.8 M6 x 1.0 M8 x 1.25 M8 x 1.25 M10 x 1.5 M10 x 1.5 M12 x 1.75 M14 x 2.0 8 10 12 15 18 18 22 22 28 33 12 16 20 25 32 40 50 63 80 100 10 12 14 18 22 22 27 27 33 39 41 46 54 64 78 86 110 124 156 188 18 22 24 30 34 40 46 58 54 62 5.
Solenoid valve ( ): Effective area [mm2] : Metal seal Speed controller D 36 to 45 E 64.8 to 67 F 102.6 to 120 G 180 to 300 C 16.2 to 21.6 Composed effective area (mm2) 2 Standard type 1 With One-touch fittings Elbow type 1-A Refer to System Selection table, and the appropriate solenoid valve, speed control valve and bore size may be selected.
180 Angular Type Air Gripper Rack & Pinion Type MHW2 Series 20, 25, 32, 40, 50 How to Order M9BW 20 MHW2 D 1 Made to Order Refer to page 712 for details. 2 fingers Number of fingers 2 Number of auto switches Bore size 20 25 32 40 50 2 pcs. Nil 20 mm 25 mm 32 mm 40 mm 50 mm 1 pc.
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Valves: Not Provided, Allowable Kinetic Energy(J): 0.00025, Torque(N⋅m): 0.3, Operating Pressure
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 1 to Less than 3, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Valves: Provided, Allowable Kinetic Energy(J): 0.025, Torque(N⋅m): 1.8, Operating Pressure
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Provided, Allowable Kinetic Energy(J): 0.25, Torque(N⋅m): 3.1, Operating Pressure
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Provided, Allowable Kinetic Energy(J): 0.4, Torque(N⋅m): 5.3, Operating Pressure
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Provided, Allowable Kinetic Energy(J): 0.4, Torque(N⋅m): 5.3, Operating Pressure
If they align as shown in Figure 4, insert the piston slider after turning it around 180. If the direction is not correct, it will be impossible to obtain the specified holding force. Caution 1. When reattaching the head covers after disassembly, confirm that they are tightened securely.
If assembled incorrectly as shown in Fig. 2, remove and rotate the piston slider by 180, then re-insert in the correct position. If the direction is not correct, it will be impossible to obtain the specified holding force.
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 20, Valves: Not Provided, Allowable Kinetic Energy(J): 1.060
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.820
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.820
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.310
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.310
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 30, Valves: Not Provided, Allowable Kinetic Energy(J): 1.210, Torque(N⋅m): 3.14
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 30, Valves: Not Provided, Allowable Kinetic Energy(J): 1.210, Torque(N⋅m): 3.14
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.310, Torque(N⋅m): 10.8
location: Front ported, Switch: M9PW, Lead wire(m): 3, Number Of Switches: 2
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100,