Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 1 to Less than 3, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Provided, Allowable Kinetic Energy(J): 0.12, Torque(N⋅m): 1.8, Operating Pressure
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Valves: Provided, Allowable Kinetic Energy(J): 0.048, Torque(N⋅m): 3.1, Operating Pressure
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Provided, Allowable Kinetic Energy(J): 0.25, Torque(N⋅m): 3.1, Operating Pressure
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Provided, Allowable Kinetic Energy(J): 0.25, Torque(N⋅m): 3.1, Operating Pressure
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Valves: Provided, Allowable Kinetic Energy(J): 0.048, Torque(N⋅m): 3.1, Operating Pressure
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Provided, Allowable Kinetic Energy(J): 0.4, Torque(N⋅m): 5.3, Operating Pressure
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Provided, Allowable Kinetic Energy(J): 0.4, Torque(N⋅m): 5.3, Operating Pressure
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Provided, Allowable Kinetic Energy(J): 0.4, Torque(N⋅m): 5.3, Operating Pressure
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Provided, Allowable Kinetic Energy(J): 0.4, Torque(N⋅m): 5.3, Operating Pressure
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 20, Valves: Not Provided, Allowable Kinetic Energy(J): 1.060
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 30, Valves: Not Provided, Allowable Kinetic Energy(J): 1.210
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.820
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.310
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 1 to Less than 3, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 10, Valves: Not Provided, Allowable Kinetic Energy(J): 0.161, Torque(N⋅m): 1.67
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 1 to Less than 3, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 10, Valves: Not Provided, Allowable Kinetic Energy(J): 0.161, Torque(N⋅m): 1.67
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 20, Valves: Not Provided, Allowable Kinetic Energy(J): 1.060, Torque(N⋅m): 3.14
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 20, Valves: Not Provided, Allowable Kinetic Energy(J): 0.574, Torque(N⋅m): 3.14
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 30, Valves: Not Provided, Allowable Kinetic Energy(J): 1.210, Torque(N⋅m): 3.14
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 30, Valves: Not Provided, Allowable Kinetic Energy(J): 0.805, Torque(N⋅m): 3.14
port location: Front ported, Switch: M9BW, Lead wire(m): 5, Number Of Switches: 2