Accuracy: Basic Type, Size: 32, Motor Mounting Position: In-line, Motor Type: Mounting Type X, Lead Screw: C [LEY25, 3mm; LEY32, 4mm, (5); LEY63, 5mm], Stroke: 300mm, Dust/Drip Proof: Size 25, 32: w/o Enclosure; Size 63: IP5x, Dust Proof Specification, Rod End Thread: Rod End Female Thread, Mounting: Rod Flange
Accuracy: Basic Type, Size: 25, Motor Mounting Position: Top Mounting, Motor Type: Mounting Type Z, Lead Screw: C [LEY25, 3mm; LEY32, 4mm, (5); LEY63, 5mm], Stroke: 300mm, Dust/Drip Proof: Size 25, 32: w/o Enclosure; Size 63: IP5x, Dust Proof Specification, Rod End Thread: Rod End Female Thread, Mounting: Rod Flange
Accuracy: Basic Type, Size: 32, Motor Mounting Position: Top Mounting, Motor Type: Mounting Type T, Lead Screw: C [LEY25, 3mm; LEY32, 4mm, (5); LEY63, 5mm], Stroke: 300mm, Dust/Drip Proof: Size 25, 32: w/o Enclosure; Size 63: IP5x, Dust Proof Specification, Rod End Thread: Rod End Female Thread, Mounting: Rod Flange
Accuracy: Basic Type, Size: 32, Bearing Type: Slide Bearing, Motor Mounting Position: Top Mounting, Motor Type: Mounting Type Z, Lead Screw: A [LEYG25, 12mm; LEYG32, 16mm, (20)], Stroke: 300mm, Guide Option: w/Grease Retaining Function
Accuracy: High Precision Type, Size: 25, Bearing Type: Slide Bearing, Motor Mounting Position: Top Mounting, Motor Type: Mounting Type X, Lead Screw: A [LEYG25, 12mm; LEYG32, 16mm, (20)], Stroke: 300mm, Guide Option: w/Grease Retaining Function
Accuracy: Basic Type, Size: 32, Bearing Type: Slide Bearing, Motor Mounting Position: Top Mounting, Motor Type: Mounting Type Z, Lead Screw: C [LEYG25, 3mm; LEYG32, 4mm, (5)], Stroke: 300mm, Guide Option: w/Grease Retaining Function
Magnet: Built-in Magnet, Mounting: Basic, Female Thread on Both Covers, Direct Mounting, Bore Size: 20mm, Port Thread: M5, Stroke: 300mm, Rod End Thread: Female Thread, Mounting Nut: -, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Bore Size: 100mm, Port Thread: Rc, Stroke: 300mm, Low Friction Direction: Pressure at Head Side, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Bore Size: 80mm, Port Thread: G, Stroke: 300mm, Low Friction Direction: Pressure at Head Side, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in Magnet, Mounting: Foot, Bore Size: 80mm, Port Thread: Rc, Stroke: 300mm, Low Friction Direction: Pressure at Head Side, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in Magnet, Mounting: Foot, Bore Size: 80mm, Port Thread: NPT, Stroke: 300mm, Low Friction Direction: Pressure at Head Side, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(