Order IDF 100 F 30 Air-cooled Nil B C K P R V Nil 1 2 3 Size Size Air compressor size Note) 100 125 150 100 kW 125 kW Heat exhausting direction 150 kW Note) Note that the above value is for reference only.
43 P 25 40 65 90 P 30 50 70 90 Model CXWM10-25 CXWM10-50 CXWM10-75 CXWM10-100 Model CXWL10-25 CXWL10-50 CXWL10-75 CXWL10-100 53 53 CXWM20, CXWL20, CXWM32, CXWL32 F P 4-J Herical insert thread depth K CXWM25 CXWL25 F 28.5 31 33.5 33.5 46 58.5 71 83.5 F 31.5 31.5 56.5 56.5 69 81.5 94 106.5 P 25 45 65 90 90 90 90 90 P 65 90 65 90 90 90 90 90 I I Stroke 25 mm 50 mm 75 mm 100 mm 125 mm 150 mm
D I M E N S I O N S ( I N C H) S TA N D A R D S I N G L E A C T I N G S P R I N G E X T E N D D O U B L E C L E V I S T Y P E NCJ2D_-_T ZZ 50 100 150 200 300 400 500 3.73 3.94 4.23 4.71 3.91 4.12 4.41 4.89 5.31 5.92 6.69 *Clevis Pin Included S Z D GA NB U Bore Size A B C CD CX MM NA R 50 100 150 200 300 400 500 50 100 150 200 300 400 500 H 0.157 0.31 0.93 0.31 10 (3/8) 0.60 0.47 0.55 0.187
filter with manual drain P P P Regulator P P P P P P Air release valve P P P P P P Pressure switch P P Blanking plate (Air release valve) P P Blanking plate (Filter, Regulator) P Blanking plate (Pressure switch) P P P P P Thread type Nil Rc F G N NPT T NPTF Note) Electrical entry: Control unit can not be removed except L and C kits. 2 stations 2 stations 2 stations 2 stations 2 stations
thread length E TC X F WP WP GW GP QW PW 4 x LD D Piping port P Operating direction A 7 W K G Piping port P Operating direction B Piping port P (Plug) Operating direction B HS CR With switch rail Q + Stroke Z + Stroke HR Plug 22 8 Piping port P Operating direction B Piping port P (Plug) Operating direction B 8 Piping port P Operating direction A 12.5 19.5 16 Plug REBR15 REBR15 REA (mm) A
(n=2, 4, 6) 65+50(n2) n2 2 20+50( ) (n=2, 4, 6) D-H7LF 10 65 20 n2 2 D-B5 D-B6 15+50( ) (n=2, 4, 6) 20+50( ) (n=2, 4, 6) 10 75 15 75+55(n2) n2 2 D-B59W 15 75 20 D-A3lA D-G39A D-K39A D-A44A 35+30(n2) 10 100 35 100+100(n2) Mounting Bracket Auto Switch Mounting Band Refer to p.1.4-35 for part numbers of the mounting brackets.
Rod end nut 2-P through M5 x 0.8 (32: Rc 1/8) Bleed port 16 to 32 Width across flats L 2-P through 4-T counterbore A' Auto switch Rod End Nut/Accessory Material: Carbon steel Part no.
50 MLU 50 40 30 50 40 30 40 ML1C 20 20 [Example] D10 10 5 4 3 5 4 3 -X 202 2 1 100 200 300 400 500 1000 1 100 200 300 400 500 1000 Data Maximum speed: V (mm/s) Maximum speed: V (mm/s) Graph (7) Graph (4) 0.5 MPa P 0.5 MPa P 1000 1000 100 80 500 400 300 500 400 300 63 100 100 80 50 40 80 200 200 63 63 100 100 Load weight: m (kg) Load weight: m (kg) 50 50 50 40 30 50 40 30 40 40 20
(3) 0.4 MPa P < 0.5 MPa 0.4 MPa P < 0.5 MPa 1000 1000 CLQ 100 500 400 300 500 400 300 80 MLGP 100 63 200 200 50 40 80 RLQ Load weight: m (kg) Load weight: m (kg) 100 100 63 50 MLU 50 40 30 50 40 30 40 ML1C 20 20 [Example] D10 10 5 4 3 5 4 3 -X 202 2 1 100 200 300 400 500 1000 1 100 200 300 400 500 1000 Data Maximum speed: V (mm/s) Maximum speed: V (mm/s) Graph (7) Graph (4) 0.5 MPa P
open from the fully closed state. 100 Vacuum break flow rate [L/min (ANR)] 0 10 20 30 40 50 60 70 80 90 P = 0.5 MPa P: Supply pressure [MPa] P = 0.4 MPa P = 0.35 MPa P = 0.3 MPa P = 0.2 MPa 0 1 2 3 4 5 6 7 8 9 Number of needle rotations * The flow rates shown in this graph are representative values for the ejector with silencer exhaust specification, and the suction flow may vary depending
Note 7) Fixed unit: kPa 100 to 100 kPa/PNP open collector 2 outputs, with suction filter 100 to 100 kPa/NPN open collector 1 output + analog voltage, with suction filter 100 to 100 kPa/PNP open collector 1 output + analog voltage, with suction filter Suction filter only !
(B) 2 (A) 4 (B) 2 (B) 2 (A) 4 (A) 4 Symbols 100 Effective area (Cv factor) % 5 3 (EB) (EA) 5 3 (EB) (EA) 5 3 (EA) (EB) 75 1 (P) 1 (P) 1 (P) 50 P port regulated A port regulated (P port controlled A port regulated) B port regulated (P port controlled B port regulated) 0.1 0.15 0.2 0.25 Set pressure MPa How to Order Interface Regulators ARBY3000 05 P 2 ARBY5000 00 P 2 Regulated port Regulated
50/6 3 25/3 Nil P R None (Standard) 5 With fitting for purge air discharge 10 20 30 50 60 75 100 100/11 200/22 300/35 500/60 600/65 750/80 1000/110 Flow direction (Right Left) With dew point indicator S Standard equipment Note) In the case of two or more options, indicate them alphabetically.
(B) 2 (A) 4 (B) 2 (B) 2 (A) 4 (A) 4 Symbols 100 Effective area (Cv factor) % 5 3 (EB) (EA) 5 3 (EB) (EA) 5 3 (EA) (EB) 75 1 (P) 1 (P) 1 (P) 50 P port regulated A port regulated (P port controlled A port regulated) B port regulated (P port controlled B port regulated) 0.1 0.15 0.2 0.25 Set pressure MPa How to Order Interface Regulators P 2 ARBY5000 00 ARBY3000 05 P 2 ARBY7000 Regulated port
D 4 4 6 6 E 60 90 90 90 F 30 60 60 60 G (50) (50) 100 100 Model LXFH5BC-25 LXFH5BC-50 LXFH5BC-75 LXFH5BC-100 Positioning Time Guide (for Horizontal Mount) For transfer load of 2kg For transfer load of 0kg Positioning time (sec) Positioning time (sec) Positioning distance (mm) Positioning distance (mm) 100 100 50 50 10 10 1 1 10 10 10.1 10.1 5.1 5.1 1.1 1.1 0.2 0.2 Speed (mm/s) Speed (mm/s
3-position 0 3 Regulator port P port A port (P port control type A port regulated) B port (P port control type B port regulated) P P port A port (P port control type A port regulated) B port (P port control type B port regulated) P Option A1 A1 With pressure gauge (for odd no. station) With pressure gauge (for even no. station) Without pressure gauge 05 B1 B1 Option 06 00 M1 With pressure
With External Pilot Specifications (Pitch) 24 P = 24 65.8 20 25 11 E 3/5 E 3/5 E 3 A E 3 A 4 A 4 A 4 A 4 A 4 4 A 4 A 4 A 4 A 4 13.7 14.5 35.8 35 58.3 74.8 P 1 P 1 B 2 B 2 B 2 B 2 B 2 P 1 P 1 B 2 B 2 B 2 B 2 B 2 One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.: 12 3/8" One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 8, 5/16" 10, 3/8" 12 X PE X PE Rc 3/8 [1(P), 3(E)