SMC Corporation of America
Elite Part Number Search
Search Results "CHDKDB25-35-A93"

Rc1/8 13 13 23 11 12 14 Model QQ SS UU XX 16 16 24 MY1H25 MY1H32 MY1H40 26.5 40 47 6 11 12 18 32 35 WXX WX V V R D Hole Size for Centralized Piping on the Bottom (Machine the mounting side to the dimensions below.)

19 49 60 9 M10 x 1.5 Rc 1/4 64 89.5 35 19 For rod nut and accessory bracket, refer to page 10-12-20.

(mm) D-A90V D-A96V D-A93V 22 Bore size D-M9V D-F9WV D-M9 D-F9W D-A90 D-A96 D-A93 (mm) 32 20 32 Mounting pattern q, w 35 Mounting pattern e 20 12 Mounting of Auto Switch As shown below, there are 3 ways to mount the auto switch according to 3 types of electrical entries. Insert the auto switch into the switch groove.

19 49 60 9 M10 x 1.5 Rc 1/4 64 89.5 35 19 For rod nut and accessory bracket, refer to page 10-12-20.

38.5 9 (9.5) 31.5 35 6.5 10.5 9.5 13.5 8.5 (9) 13 (13.5) Long Stroke Bore size (mm) 32 40 38.5 42 38 41.5 18 24 18 24 10 13.5 10 13.5 9.5 (10) 17.5 (18) 31.5 35 7 10.5 15 21 34 37.5 10 13.5 18 24 35 38.5 13 (13.5) 23.5 (24) ( ): Denotes the values of D-A72. 8-27-11 12 Series CXT Operating Range (Dimensions) Bore size (mm) 12 Auto switch model 16 20 25 32 40 D-F7, D-F7V D-J79, D-J79C D-F7W

5.5 34 64 22 76 34 76 Mounting pattern e DB3 A3 5 35 70 23 82 35 82 5 40.5 99.5 28.5 111.5 40.5 111.5 -X These values are given as a guideline including the hysteresis and are not guaranteed.

Dimensions L A LA Attached from top W C PA MM Note 1) M F HB HA Note 2) Attached from bottom: MD R Body B (mm) Note 1) Note 2) B C F HA HB L LA MM MD M PA R W A Model CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 16 35 6.5 5.5 16.5 23 57 25 M4 x 0.7 M3 4 25 6 36 18 36 6.5 5.5 17 23.5 66 30 M4 x 0.7 M3 4 27 6 37 20 46 8.0 5.5 21 28.5 70 30 M5 x 0.8 M4 5 36 7 47 22.5 60 9.5 6.0 27.5 36 80 35 M6 x 1.0

Cylinder bore size Lead wire length (m) 16 20 25 32 40 50 63 16mm 20mm 25mm 32mm 40mm 50mm 63mm Auto switch type Indicator light Load voltage Wiring (output) Electrical entry Special function Applicable loads Type Reed switch Solid state switch Electrical entry direction 3 (L) 0.5 (Nil) 5 (Z) DC AC Perpendicular In-line IC circuit 5V 12V 100V or less A90V A90 No Relay PLC 24V 2-wire A93V A93

D-P3DWA A B Auto switch Hs Ht Auto Switch Proper Mounting Position (mm) Auto switch model D-P3DWA RSQ B 43 Hs 35 Ht A Bore size RSG 50 63 80 19 6.5 21 10 48.5 44 RS2H RS2H 35 17 56.5 54 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.

IC circuit 5V A76H A96V A96 A72H A73H A72 A73 A73C 200V Grommet A93V A93 Reed switch Solid state switch Yes 100V 12V Relay, PLC 2-wire 24V Connector Diagnostic indication (2-color display) A79W Grommet F9NV F9PV F9BV F9NWV F9PWV F9BWV F9N F9P F9B F9NW F9PW F9BW F9BA F79 F7P J79 F79W F7PW J79W F7BA F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV 3-wire (NPN) IC circuit 5V, 12V 3-wire

Allowable load mass on guides and moment Allowable moment [Nm] M1 1.3 2.6 8.6 17 30 67 96 Bore size (mm) Allowable load mass on guides m [kg] 6 10 15 20 25 32 40 M2 1.4 2.9 8.9 18 35 82 124 M3 1.3 2.6 8.6 17 30 67 96 9 15 35 60 104 195 244 The table above indicates the maximum performance of the guide, but does not show the actual allowable work load mass.

Symbol -X2172 With Boss in Head End 3 Z X2172 MKB Bore size Stroke Rotary direction Body option With boss in head end 2 Bore size 20 25 32 40 50 63 Ah9 13 15 21 28 35 35 0 0.043 0 0.043 Ah9 0 0.052 0 0.052 0 0.062 0 0.062 Symbol -X2177 The Dimension of Head End Flange is the Same as the Current MK and MK2 Series 4 Z X2177 MKG Bore size Stroke Rotary direction Body option The dimension of

Note 3) ( ) in column W denotes the dimensions of D-A93. Operating Range Bore size (mm) Auto switch model 6 10 16 20 5 6 9 11 D-F9W/F9WV D-M9/M9V D-A9/A9V 3 (2) 3.5 (2) 5.5 (3) 6.5 (3.5) Since this is a guideline including hysteresis, not meant to be guaranteed. (Assuming approximately 30% dispersion.)

Please consult with SMC regarding water resistant type with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked with are produced upon receipt of order.

IC circuit 5 V, 12 V 3-wire (PNP) Relay, PLC 2-wire 12 V Grommet 5 V, 12 V 24 V 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color indication) 12 V 2-wire Lead wire length symbols: 0.5 mNil (Example) A93 3 mL (Example) A93L 5 mZ (Example) F9NWZ Since there are other applicable auto switches than listed, refer to page 8-10-22 for details.

IC circuit A96 A96V 5 V Yes 24 V Grommet A93V2 A93 A90 Relay, PLC 100 V 2-wire 12 V A90V IC circuit No 100 V or less 1 Although it is possible to mount water resistant type auto switches, note that the rotary actuator itself is not of water resistant construction. 2 1 m type lead wire is only applicable to D-A93. Auto switches marked with a are produced upon receipt of orders.

mounting Bottom mounting Application Example Assembly lines, inspection lines etc. with turning operations Front mounting Side mounting Series Variations Bearing type Bore size (mm) Standard stroke (mm) Model Slide bearing MGTM 63 80 25, 50, 75, 100, 125, 150, 175, 200 Ball bushing bearing MGTL 100 8-24-2 3 Cylinder with Turntable Series MGT 63, 80 100 How to Order MX MTS M 63 50 11 Y59A S S A93