Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 120, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, COPPER FREE, ACTUATOR, CQS COMPACT CYLINDER, I6, 25MM CQS COPPER FREE, .51440 lb
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 25mm, Stroke: 100mm, Option: CM (Rubber Bumper,Rod End Male Thread), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5m, Lead Wire or Prewired Connector: Z (5m)
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 25mm, Stroke: 50mm, Option: CM (Rubber Bumper,Rod End Male Thread), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5m, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 25mm, Stroke: 50mm, Option: M (Rod End Male Thread), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 25mm, Stroke: 75mm, Option: CM (Rubber Bumper,Rod End Male Thread), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 25mm, Stroke: 75mm, Option: CM (Rubber Bumper,Rod End Male Thread), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 25mm, Stroke: 20mm, Option: Standard (Rod End Female Thread), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5m, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 25mm, Stroke: 35mm, Option: M (Rod End Male Thread), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5m, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 25mm, Stroke: 50mm, Option: M (Rod End Male Thread), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5m, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 25mm, Stroke: 50mm, Option: M (Rod End Male Thread), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5m
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 25mm, Stroke: 175mm, Option: CM (Rubber Bumper,Rod End Male Thread), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5m