Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: Rod End Male Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Rod End Male Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: Rod End Male Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, ME, 40MM CQ2-Z DBL-ACT AUTO-SW, 0.83285 lb
Magnet: None, Mounting: B (Through Hole, Standard), Bore Size: 16mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 10mm, Action: D (Double Acting), Rod End: F (Round Bar w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 16mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 10mm, Action: D (Double Acting), Rod End: F (Round Bar w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 20mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 10mm, Action: D (Double Acting), Rod End: F (Round Bar w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 16mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 10mm, Action: D (Double Acting), Rod End: F (Round Bar w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 20mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 10mm, Action: D (Double Acting), Rod End: F (Round Bar w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Water Resistant: None, Port Thread: TN (NPT), Stroke: 10mm, Action: D (Double Acting), Rod End: F (Round Bar w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 20mm, Water Resistant: None, Port Thread: TN (NPT), Stroke: 10mm, Action: D (Double Acting), Rod End: F (Round Bar w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)
Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 16mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 10mm, Action: D (Double Acting), Rod End: F (Round Bar w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 32mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 10mm, Action: D (Double Acting), Rod End: F (Round Bar w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 20mm, Water Resistant: None, Port Thread: TN (NPT), Stroke: 10mm, Action: D (Double Acting), Rod End: F (Round Bar w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)
Magnet: None, Mounting: B (Through Hole, Standard), Bore Size: 20mm, Water Resistant: None, Port Thread: TN (NPT), Stroke: 10mm, Action: D (Double Acting), Rod End: F (Round Bar w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 10mm, Action: D (Double Acting), Rod End: F (Round Bar w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)
Magnet: None, Mounting: B (Through Hole, Standard), Bore Size: 20mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 10mm, Action: D (Double Acting), Rod End: F (Round Bar w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)
Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 20mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 10mm, Action: D (Double Acting), Rod End: F (Round Bar w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 100mm, Port Thread Type: TF (G 32-100 Bore), Stroke: 10mm, Body Option: F (Rear Boss Mount), Auto Switch Groove: Z (Auto Switch Mounting Grooves)