SMC Corporation of America
Elite Part Number Search
Search Results "CDNA2C50-75-D-M9N"

Confirm the Coordinates and Moments in Model Selection on page 1229 for details of floating Y and Z axes. 1196 MY1B Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at Stroke End) MY1B (Basic type) 25 to 40 Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model D-A9 D-A9V A A Bore size A 25 32 40 79 83 112.5 116.5 133.5

D-M9N, D-M9B Reed switch Solid state Action D Double acting The minimum stroke for auto switch mounting and operating range are the same as standard products.

Recommended tightening torque Auto switch model Recommended tightening torque [Nm] D-M9 0.05 to 0.15 D-M9A (Water resistant) 0.05 to 0.10 Fig. 8 D-F8 0.10 to 0.20 Set screw Auto switch 29 - Auto switch proper mounting position at rotation end Table 11 Auto Switch Rotation range / Actuation / most sensitive position A A A A B B B B D-M9 D-F8 Magnet Operation range at optimum set position (

Note 4) D-Z7 and D-Y types cannot be mounted. 25 to 63 (mm) Auto switch model D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-Y7BA A B C D D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-Y7BA D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-Y7BA D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-Y7BA D-A9 D-M9 D-M9W D-M9A D-A9 D-M9 D-M9W D-M9A D-M9 D-M9W D-M9A D-A9 D-M9 D-M9W D-M9A D-A9 Bore size (mm) 25 32 40 50 63 19 23 18 98 94 99 42 38 43 75 79 74 22.5 26.5

/Y7PV D-Y7W/Y7WV D-Y7BA D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BA 5 5 5 5.5 5.5 5 5 5 5.5 5.5 Perpendicular electrical entry type and D-Y7BAL cannot be mounted on 16, 20, 50 and 63.

Dimensions and the most sensitive positions are same as the conventional types. s D-M9N (s-vvire, NPN output) M-F9N -^ D-W9P *8 c-"*t"*r D-FQB 17 D-MgN D-MgP Nwtypes D-MgB nil;'Y,r dCl D-MgP (3-wke, PNP output) D-MgB (2-wire) Range of load 5 t o wire:4 timesrn" New types tr{lur$ D-FgB 5 to 40mA D.M9B 2.5 to 40mn lead wire is available as siandard. 41ime6 more bl f e x b e Indicator Light:

Weight (g) Auto switch model D-F6N D-F6P D-F6B 20 0.5 m (Nil) 19 3 m (L) Lead wire length 53 50 5 m (Z) 80 75 Dimensions (mm) D-F6 D-F6B 8.5 (22) 3.2 Indicator light (24) 16 Most sensitive position 7 2.7 10.6 7 29 D-F6N/F6P DD(22) 3.2 Most sensitive position 7 1609 Auto Switches Precautions 1 Be sure to read this before handling.

Mounting Position (Detection at Stroke End) and Its Mounting Height D-M9 D-M9W D-M9A D-A9 A 22 [24] (24.5) W B [ ]: Value of the D-M9A ( ): Value of the D-A90/A93 D-M9V D-M9WV D-M9AV D-A9V A 20 (22) W B ( ): Value of the D-M9AV/A9V (mm) D-A9, D-A9V D-M9W, D-M9 D-M9WV, D-M9V A 16.5 15.0 22.0 30.0 D-M9A A 16.5 15.0 22.0 30.0 D-M9AV A 16.5 15.0 22.0 30.0 Bore size (mm) 6 10 16 20 B 2.5 7.5

Proper Auto Switch Mounting Position (Detection at stroke end) MX A B MTS MY MY3A D-A9, D-A9V (mm) D-F9W, D-F9(W)V (mm) D-M9, D-M9V (mm) CY A B Operating range Bore size 16 25 40 63 A B Operating range Bore size 16 25 40 63 B Operating range Bore size 16 25 40 63 A 088.5 084.5 26.5 084.5 22.0 26.5 2 06.5 3.0 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080

D-M9B D-M9N, D-M9P D-A93 Load voltage Load current range Indicator light Application 24 VDC (10 to 28 VDC) 28 VDC or less 24 VDC, 100 VAC 2.5 to 40 mA 40 mA or less 5 to 40 mA, 5 to 20 mA 24 VDC relay, PLC IC circuit, Relay, PLC Relay, PLC Solid state auto switch PLC: Programmable Logic Controller Refer to page 920 for the applicable auto switch list. 905 Rotary Actuator 11-CRA1-Z Rotation

How to Order Standard B 20 30 D C CQSY B 20 30 D C F9BW S CDQSY With auto switch Number of auto switches With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.

Magnet: D (Built-in), Mounting: A [Double End Tapped [ø32 - ø50]], Bore Size: Ø32 mm, Port Thread: M Thread [ø12-ø25]; Rc [ø32-ø100], Stroke: 75 mm, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: Ø32 mm, Port Thread: M Thread [ø12-ø25]; Rc [ø32-ø100], Stroke: 75 mm, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3 m)

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: Ø32 mm, Port Thread: M Thread [ø12-ø25]; Rc [ø32-ø100], Stroke: 75 mm, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: Z (5 m)

Magnet: D (Built-in), Mounting: A [Double End Tapped [ø32 - ø50]], Bore Size: Ø32 mm, Port Thread: M Thread [ø12-ø25]; Rc [ø32-ø100], Stroke: 75 mm, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5 m Cord Length, M8-3 Pin Connector)

Magnet: D (Built-in), Mounting: A [Double End Tapped [ø32 - ø50]], Bore Size: Ø40 mm, Port Thread: M Thread [ø12-ø25]; Rc [ø32-ø100], Stroke: 75 mm, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal

Magnet: D (Built-in), Mounting: A [Double End Tapped [ø32 - ø50]], Bore Size: Ø63 mm, Port Thread: M Thread [ø12-ø25]; Rc [ø32-ø100], Stroke: 75 mm, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal