switches cannot be installed in Area C in the case of 15.
C D E F Dimensions Part no.
B A C B A C B A C B A C B A C B A C B A C kit 34.3 47.1 67.9 94.1 (Single) 98.6 (Double, Dual 3 port valve) 107.6 (3 position) P kit 35 5.5 28.1 12.7 J kit T Triangle mark indicator position EXH outlet 2 x M4 DIN rail clamp screw 49.4 9 kit Release for switching connector direction Applicable connector: Flat ribbon cable connector (26P) (Conforming to MIL-C-83503) U side Stations D side n
M N C D 4-O T Q 2-P S U W E B K L AA A R X AB I AP Y + Stroke Z + Stroke J V 8-AF AC AD AE 100 piston rod end connection For standard strokes (mm) Bore size (mm) Stroke range (mm) AC G H AB AF AA AE AD F N M D L C K B J AP I A E 63 80 100 75, 100 125, 150 200, 250 300 15 20 depth 14.5 M16 x 2 depth 28 25 25 50 170 13.5 100 66 140 180 30 135 M12 x 1.75 depth 24 228 117 60 65 200 200 15 20
B L F G C D T Basic style Axial foot style Rod side flange style Head side flange style Single clevis style Double clevis style Center trunnion style Cylinder stroke (mm) 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 500, 600 50, 63 Built-in Magnet Cylinder Model 25, 50, 75, 100, 125, 150, 175, 200, 250, 300,
, 300 500 10 150, 200, 250, 300, 350, 400 450, 500 750 15 20 1000 200, 250, 300, 350, 400, 450 500, 600, 700, 800 25 1500 32 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 40 1500 Note) Intermediate strokes can be arranged in 1mm increments.
SMC vacuum pad Search http://www.smcworld.com Catalogs ZP2 ES100-76 ZP3 ES100-100 Best Pneumatics Pad diameter Symbol 16 18 20 25 30 32 40 46 50 63 80 100 125 150 250 300 340 U C C C C C C MU EU AU C C C C C C C UM UT C ( ( CT C C B C C C C C Note) Note) J ( ( ( MB ( ZJ ( ( D C C C AN Note) Note) Note) MT ( ( ( W U H C C C C C C ( ( ( HT ( ( HB C C C C ( C C ( 30 x 50 ( HW U ( ( ( (
C shape 8 for axis C shape 10 for axis C shape 10 for axis NT-02 NT-03 NT-G04 C shape 8 for axis C shape 10 for axis 13 17 19 20 25, 32 40 15.0 19.6 21.9 12.5 16.5 18 M8 M10 X 1.25 M14 X 1.5 5 6 8 20 IY-G02 0.040 0.076 8 CD-G02 16.2 20 21 7.6 1.5 0.9 0.040 0.076 8 0.9 7.6 38.6 43.4 1.5 IY-G03 0.040 0.076 10 0.040 0.076 10 CD-G25 20.2 25.6 1.55 25, 32 9.6 1.15 9.6 42.6 1.55 1.15 25 48 C shape
(Values at the initial period) Note 4) Based on JIS C 0920. Note 5) Based on JIS C 4003.
Basic Compact LEHZ25 LEHZ25L 250 250 200 200 Overhang H [mm] Overhang H [mm] 70%, 40% 150 150 40% Pushing force 100% Pushing force 100% 100 100 70% 50 50 0 0 50 100 150 200 250 0 0 50 100 150 200 250 Gripping point L [mm] Gripping point L [mm] LEHZ32 250 200 Overhang H [mm] 150 40% 100 Pushing force 100% 70% 50 0 0 50 100 150 200 250 Gripping point L [mm] LEHZ40 250 200 Overhang H [mm] 150
Q2 C Q2W C Q2K C Q2KW C Q2 S XB10 Standard model no.
Width across flats KB B C V MM BH1 BH2 BH3 TX D E B1 C B ZZ + Stroke S + Stroke H A K BN N1 N MA MB F AL H1 TT B C B1 C B TY With rod boot d e 10.2 f h 10.2 l [mm] Bore size A AL B B1 BH1 BH2 BH3 BN BP C D E F GA GB GC GD GE GF H H1 J 32 22 19.5 46 46 23 38.5 46.5 59 1/8 32.5 12 30 13 37.5 13 37.5 18.5 4 13 47 6 M6 x 1.0 40 30 27 57 52 28.5 42.5 48.5 73 1/8 38 16 35 13 59.5 14 44.5 19.5 4
L Symbol (Dimension L) Station Symbol (Dimension L) Station 430 190 Station 2 Station 14 450 210 Station 3 Station 15 A C B A C B A C B A C B 470 230 Station 4 Station 16 490 250 Station 5 Station 17 510 270 Station 6 Station 18 For double wiring SSQ1000 F 41A 350 530 290 Station 7 Station 19 550 310 Station 8 Station 20 570 330 Station 9 Station 21 590 350 Station 10 Station 22 L 610 370
This may cause damage to the machinery. ) m m ( e z i s e r o B e v l a v n o i h s u C s t a l f s s o r c a h t d i W h c n e r w n o g a x e H 0 5 , 0 5 , 2 3 7 4 2 1 C 0 1 2 3 B M 5 . 2 5 . 2 y e k h c n e r w n o g a x e H 0 0 1 , 0 8 , 3 6 0 5 2 1 C 0 1 3 6 B M 4 4 y e k h c n e r w n o g a x e H Mounting & Piping 2. Be certain to activate the air cushion at the stroke end.
N.O. 2 B A 2-position double (Rubber) 4-position dual 3-port valve (C) VQC 1/2 VQC 1/2 2(B) 4(A) 2(B) (A)4 Note) C VQC 4/5 (R1)5 1 (P) 3(R2) C Turn locking type (Manual) 1(P) 5(R1) 3(R2) N.C. N.O.
83503 Flat ribbon cable connector socket: 20 pins MIL with strain relief; Conforming to MIL-C-83503 Flat ribbon cable connector socket: 10 pins MIL with strain relief; Conforming to MIL-C-83503 Flat ribbon cable connector socket: 20 pins MIL with strain relief; Conforming to MIL-C-83503 SY D-sub connector: Conforms to MIL-C24308 Flat ribbon cable Terminal block (M3) 9 pins Terminal block
20 250 450 30 200 15 320 350 30 530 40 68 8-6-4.
Flow Switch for Water Flow rate/Analog output Fluid temperature/Analog output PF3W7/5 B Output Output A C 4/16/40 100 250 C C D A B Voltage output 1.5 V 6 mA 1.4 V 1.8 V 1 V 5 V 0.6 V 1 V Voltage output Current output 5.6 mA 7.2 mA 4 mA 20 mA 2.4 mA 4 mA Current output Minimum Model Rated flow [L/min] C D Maximum B PF3W B 5 V 5.4 V Voltage output PF3W704/504 PF3W720/520 PF3W740/540 PF3W711
Speed (mm/s) 250 3.5 2.3 1.5 1.2 1.1 500 2.4 1.8 1.4 1.2 1.1 Values will vary slightly depending on the operating conditions. A B C D Non-standard Motors: The following motors will be mounted when a motor mounted type is specified.