SMC Corporation of America
Elite Part Number Search
Search Results "CDLST125TN-400-D"

Confirm the Coordinates and Moments in Model Selection on page 1229 for details of floating Y and Z axes. 1196 MY1B Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at Stroke End) MY1B (Basic type) 25 to 40 Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model D-A9 D-A9V A A Bore size A 25 32 40 79 83 112.5 116.5 133.5

Example) D-F9NL Main switch circuit Main switch circuit Output Black [White] () Blue [Black] D-F9P (+) Brown [Red] Auto Switch Dimensions (mm) 1in=25.4mm Output Black [White] D-F9N, D-F9P, D-F9B () Blue [Black] D-F9B (+) Brown [Red] L dimension (mm) Part No.

Example) D-F9NL Main switch circuit Main switch circuit Output Black [White] () Blue [Black] D-F9P (+) Brown [Red] Auto Switch Dimensions (mm) 1in=25.4mm Output Black [White] D-F9N, D-F9P, D-F9B () Blue [Black] D-F9B (+) Brown [Red] L dimension (mm) Part No.

Technical Data 1219 MY1H Series Auto Switch Mounting Auto Switch Proper Mounting Position Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9AL D-M9AV Auto switch model D-A9 D-A9V A A Bore size A A 25 32 40 81 85 112.5 116.5 133.5 137.5 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.

U side D side D D D D D D 3 2 1 Stations How to Order Solenoid Valve 10 SV 1 1 0 0 F 5 Note) Clean series Note) Available with manifold block for station additions. Refer to the WEB catalog.

/C8 D-H7 A B 11.5 8.5 16 Auto switch D-C7/C8, D-H7 D-B5/B6 D-G5/K5 A 12 14.5 B 24.5 Auto switch D-B5/B6, D-G5/K5 D-B7/B8 D-G7/K7 8.5 A 14.5 B 11 Auto switch D-B7/B8, D-G7/K7 Auto Switch Mounting Position D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C Auto switch model D-C7/C8 D-C73C D-C80C D-G5 D-K5 D-G5NYL D-B59W D-H7 D-H7C D-H7W D-H79F D-H7BAL Bore size (mm

8 6 D-F9, D-F9W 5 4 D-Z7, Z80 9 9 11 A B D-Y59, Y7P D-Y7W 6 6 6 Switches cannot be mounted in some cases.

8 6 D-F9, D-F9W 5 4 D-Z7, Z80 9 9 11 A B D-Y59, Y7P D-Y7W 6 6 6 Switches cannot be mounted in some cases.

Auto Switch Mounting Height (mm) D-Z7, Z-80 D-Y59 D-Y7P D-Y7W D-F5, D-J5 D-F5F D-F5W, D-J59W D-F5BAL, D-F5NTL D-A5 D-A6 D-A59W D-A3 D-G39 D-K39 D-Y69 D-Y7PV D-Y7WV Bore size D-Y7BAL D-A44 D-P5DWL (mm) Ht Hs Ht Hs Hs Hs Hs Hs Hs Hs Ht Ht Ht Ht Ht Ht 32 24.5 35 25 32.5 25.5 77 38 67 26.5 30 23 27.5 31 27.5 23 23 40 27.5 38.5 27.5 36.5 29.5 81.5 42 71.5 30 34 26 27.5 33 27.5 26 26 50 34.5 43.5

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 150mm

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 200mm

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 500mm

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 600mm

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 700mm

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 250mm

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 350mm

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Magnet: Built-in, Mounting: Center Trunnion, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: NPT, Stroke: 150mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: Built-in, Mounting: Center Trunnion, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: NPT, Stroke: 200mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -