SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2L16-60AZ-W-A93V-B"

Model of Switch spacer BMY3-016 33 - Auto switch operation principle Fig. (14) Auto switch operation principle In the diagram above, auto switch B is ON. When pressure is applied from A, the piston moves to B, causing the shaft to rotate clockwise. At this time, magnet B goes out of the movement range of auto switch B, causing auto switch B to turn OFF.

Magnet: Built-in, Mounting: Double Clevis, Bore: 10mm, Stroke: 60mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: Double Knuckle Joint, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion: Air Cushion, Series: J2

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire

Modify the detecting position while the auto switch is secured at the position of (3) in the figure. y r a w t Auto switch mounting bracket b Auto switch mounting screw M2.5 x 0.45 x 6 L q Cylinder BQ2-012 is a set of a and b shown above.

-H -R -W N L Stroke Axial foot style: CBM2L Bore size LH B 4 x LD 2 x LC LT X Y Y X LS + Stroke Z ZZ + Stroke LZ LX -H -R -W N L Stroke N L Stroke Head side flange style: Rod side flange style: CBM2F Bore size -H -R -W CBM2G Bore size 4 x FD Mounting hole C2 2 x FD Mounting hole FY B FX FZ Z + Stroke FT FT Z 20 to 32 40 -H -R -W N L Stroke Single clevis style: CBM2C Bore size CD U L RR CX

Rail mounting type (Different-surface mounting) Applicable auto switch: D-P4DW [CKQG] [CLKQG] B B U U A A Applicable auto switch: D-P74/D-P79WSE [CKQP] [CLKQP] B B U U A A Operating Range Operating range Auto switch model Cylinder model D-P4DWS D-P4DW D-P74 D-P79WSE C(L)KQG 6.5 C(L)KQP 10 Since this is a guideline including hysteresis, not meant to be guaranteed.

rate filtr ation FGB type: High flow suspended type Ideal for high flow filtr ation FGC type: High pressure lo w flow rate type FGG type: Ideal for high flow filtr ation Easy handling of filtered impur ities Connection: Rc 3/8 to Rc 2 Connection: Flange JIS10K1 B to 6 B Oper ating pressure: 0.5MP a Number of elements: 1 to 28 Flange JIS and ANS1 1/2 B to 1 B (FGC type) Oper ating

Auto Switch Specifications PLC: Programmable Logic Controller RoHS compatible D-M9 W/D-M9 WV (With indicator light) UL certified lead wire (style 2844) D-M9NWV V W B 9 M D W B 9 M D W N 9 M D D-M9PWV D-M9PW Auto switch part no.

Example: Power supply is 24 VDC Internal voltage drop in auto switch is 4 V. 24 Cylinder with Lock Double Acting, Single Rod/Double Rod 32, 40, 50, 63, 80, 100 C96N Series RoHS How to Order C96N B 32 100 C J W C96ND M9BW S W C J 100 B 32 With auto switch With auto switch (Built-in magnet) Bore size 32 32 mm 40 40 mm 50 50 mm 63 63 mm 80 80 mm 100 100 mm Rod Nil Single rod W Double rod Made

LH 0.2 d CHN W W B C D E LY 4 x LD CHM MM Width across flats G CHS LT NA NB CH2 Y X X Y S + Stroke LX B LS + Stroke CHA CHA ZZ + Stroke Related Products With rod boot Dh + l 10 f l e ZZ + l + Stroke (mm) Bore size (mm) A B a d B C D E F G GA GB K LD LH LY MA NA NB MM M J LS LX LT 45 0 0.018 0 0.021 0 0.021 0 0.021 0 0.025 0 0.025 0 0.025 0 0.062 0 0.062 0 0.074 0 0.074 0 0.074 0 0.074 0 0.087

A C B 1) Initial state (0 stroke position) Stroke B Stroke A A C Precautions B 2) Double output When the air pressure is supplied to the A and C ports at the same time, the double output can be obtained in the stroke A range. Caution W W 1. Do not supply air until the cylinder is fixed with the attached bolt. 2.

AV D-Z7W/Y7B A 33 B 20 D-A3< D-G39/K39 D-A5B zHt zHt 56 34 B A 33 D-A3W/K59W G1/2 (Applicable cable O.D.) 6.8 to 9.6 D-G5BAL D-G59F/G5NTL A 49 36 HW B zHs Auto switch zHs

Cushion valve G 2 x Rc P W V Port G E Width across flats KA TX D E B C H1 AL MM MB MA N 2 x 4 x J N TY B C Width across flats B1 A H K F TT ZZ + Stroke S + Stroke With rod boot d e 10.2 10.2 f h l [mm] Bore size [mm] A AL B B1 C D E F G H H1 J K KA MA MB MM N P S TT TX TY V W ZZ 32 22 19.5 46 17 32.5 12 30 13 13 47 6 M6 x 1 6 10 16 4 M10 x 1.25 27 1/8 84 17 48 49 4 6.5 135 40 30 27 52 22

Foot: CS2L S + Stroke H K A AL F With rod boot Port Width across flats KA V W G G 2 x P (Rc, NPT, G) 4 x J Cushion valve MM D B E e LH LY 4 x LD f l LX Y N X LS + Stroke N X Y LT ZZ1 + l + Stroke h + l B C ZZ + Stroke (mm) Bore size (mm) Stroke range (mm) C B A AL B D E F G LH LS J V W K KA LD 125 140 160 50 47 Up to 1600 143 115 143 32 71 43 15 85 188 M14 x 1.5 15 17 15 27 19 50 47 Up to

} L3=50 {mm} L2=50 {mm} L2 {B L3 Item Load factors n Note (1) Max. movable load W B L2 Examine W.

D-Z7m D-Z8m D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV D-A9m D-A9mV D-F5m D-J59 D-F59F D-F5NT D-A5m D-A6m D-A59W D-G39 D-K39 D-A3m D-A44 D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B 32 10 8 6 4 6.5 4.5 11.5 9.5 0 0 4 2 0 0 3.5 1.5 5.5 3.5 3 1 40 9 9 5 5 5.5 5.5 10.5 10.5 0 0 3 3 0 0 2.5 2.5 4.5 4.5 2 2 50 10 9 6 5 6.5 5.5 11.5 10.5 0 0 4 3 0 0 3.5 2.5 5.5 4.5 3 2 63 10