SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2L16-45+45Z-B-XC10"

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 150 (1 1/2"), Stroke A: 0100 (1"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0100 (1"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: F59W--Solid State, 2-color Indication, 3 Wire NPN, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

Magnet: None, Mounting: B (Basic), Bore Size: 200 (2"), Stroke A: 0400 (4"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0100 (1"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: None, Mounting: B (Basic), Bore Size: 400 (4"), Stroke A: 0200 (2"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0400 (4"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 325 (3 1/4"), Stroke A: 0200 (2"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0200 (2"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m Lead Wire), Number: 2 pcs.

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 325 (3 1/4"), Stroke A: 0200 (2"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0200 (2"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 400 (4"), Stroke A: 1000 (10"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 1000 (10"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 400 (4"), Stroke A: 2000 (20"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 1200 (12"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 400 (4"), Stroke A: 2400 (24"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 2400 (24"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 400 (4"), Stroke A: 2800 (28"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 2800 (28"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: None, Mounting: B (Basic), Bore Size: 250 (2 1/2"), Stroke A: 0600 (6"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0400 (4"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: None, Mounting: B (Basic), Bore Size: 325 (3 1/4"), Stroke A: 0200 (2"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 1200 (12"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: None, Mounting: B (Basic), Bore Size: 400 (4"), Stroke A: 0400 (4"), Cushion A: Both Ends, Rod Boot A: J (Nylon), Stroke B: 0400 (4"), Cushion B: Both Ends, Rod Boot B: J (Nylon), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 200 (2"), Stroke A: 1000 (10"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0200 (2"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 250 (2 1/2"), Stroke A: 0400 (4"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0400 (4"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number: 2 pcs.

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 325 (3 1/4"), Stroke A: 0050 (1/2"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0100 (1"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 400 (4"), Stroke A: 0400 (4"), Cushion A: Both Ends, Rod Boot A: J (Nylon), Stroke B: 0400 (4"), Cushion B: Both Ends, Rod Boot B: J (Nylon), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: L (3m Lead Wire), Number: 4 pcs., Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 400 (4"), Stroke A: 0400 (4"), Cushion A: Both Ends, Rod Boot A: J (Nylon), Stroke B: 0400 (4"), Cushion B: Both Ends, Rod Boot B: J (Nylon), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: L (3m Lead Wire), Number: 2 pcs.

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 400 (4"), Stroke A: 0400 (4"), Cushion A: Both Ends, Rod Boot A: J (Nylon), Stroke B: 0400 (4"), Cushion B: Both Ends, Rod Boot B: J (Nylon), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl.

Air Cylinder: Standard Type Double Acting, Single Rod How to Order MB Series 32, 40, 50, 63, 80, 100, 125 RoHS 50 B 32 Z MB With auto switch MDB M9BW Z B 32 50 With auto switch (Built-in magnet) Number of auto switches Mounting type Bore size Accessories 1 Auto switch Nil No bracket N Pivot bracket 32 32 mm 40 40 mm 50 50 mm 63 63 mm 80 80 mm 100 100 mm 125 125 mm Nil Without auto switch

ISO Standards Air Cylinder: Standard Double Acting with End of Stroke Cushioning 32, 40, 50, 63, 80, 100, 125 Series CP96 Series C85 Series CP96 Series C96 Series C55 How to order 100 CP96S B W 32 J CP96SD B S W 32 100 M9BW With auto switch J With auto switch (Built-in magnet) Made to Order Mounting Refer to page 44 for details.