SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2F16-30AZ-A93-B"

Auto Switches/Proper Mounting Position at Stroke End Detection B A (mm) D-A9, D-A9V (mm) D-M9, D-M9V (mm) D-F9W, D-F9WV A A A B B B Operating range Operating range Operating range Nominal size 16 25 Nominal size 16 25 Nominal size 16 25 3 44 116 48 112 48 112 8 8.5 3.5 54 156 58 152 58 152 Auto Switch Mounting When mounting the auto switches, they should be inserted into the actuators switch

D-A9V D-F9V D-F9WV A 22 (20) 5 (7) W B The dimension in ( ) is for D-F9V and D-F9WV. (mm) D-A9, D-A9V D-F9, D-F9W D-F9V, D-F9WV Bore size (mm) A A W B W B W A B 20 25 32 22 22 13 (10.5) 19 18 9 19 11 15 24.5 24.5 9 (6.5) 15 20 5 15 7 11 26.5 26.5 11.5 (9) 17.5 22.5 7.5 17.5 9.5 13.5 Values in ( ) are dimensions for D-A93 type.

For D-A93, only outward electrical entry (D dimension) is available. Dimensions in parentheses apply to 12-CXSJ6. CXSJ10 / CXSJ10 11122122Note 2) D B Note 3) (mm) D-M9 34(35.5) 3.5(2) 24(25.5) 6.5(8) D-A93 30 (31.5) 25.5 (27) 5 (6.5) Symbol A B C D Note 1) Note 1) The above mentioned values are indicated as a guide for auto switch mounting position for stroke end detection.

L E T U B E OD 6 A P P L I C A B L E T U B E OD 6 Courtesy of Steven Engineering, Inc. !

O R E T Y P E S I D E S U P P O R T B: T H R E A D E D T H R O U G H H O L E Part No Cylinder Side Support A Side Support B A B C D E F G H J MY-S16A/B MY1C16 MY-S16A MY-S16B 61 71.6 15 26 4.9 3 6.5 3.4 M4X0.7 MY-S20A/B MY1C20 MY-S20A MY-S20B 67 79.6 25 38 6.4 4 8 4.5 M5X0.8 MY-S25A/B MY1C25 MY-S25A MY-S25B 81 95 35 50 8 5 9.5 5.5 M6X1 MY-S32A/B MY1C32 MY-S32A MY-S32B 100 118 45 64 11.7 6

MY1H40 MY3M B MY-S16A B MY-S20A B MY-S25A B MY-S32A B MY-S40A B A set of side supports consists of a left support and a right support.

D-X 571 B RSQ Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at stroke end) and Mounting Height D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-A9/A9V 12 Hs B B A B B A 16, 20 B A Hs B Hs B A Hs B A Hs B A 32 to 50 A A B A A B A Hs D-A7 D-A80 D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F79F D-F7NT D-F7BA D-A73C D-A80C D-J79C D-A79W D-F7WV D-F7V D-F7BAV 16, 20 B A Hs B A Hs

C D A B (mm) D-A9, D-A9V (mm) D-F9, D-F9V (mm) D-F9W, D-F9WV A B A B A B Bore size 16 25 32 Operating range Bore size 16 25 40 Operating range Bore size 16 25 40 Operating range 54 106 58 102 57 103 54 156 58 152 57 153 11 8.5 8.5 85 245 89 241 88 242 (mm) (mm) (mm) C D C D C D Bore size 16 25 32 Operating range Bore size 16 25 32 Operating range Bore size 16 25 32 Operating range 27 133

(Same surface) 10.5 16.5 D-A93 50 50 50 D-M9B D-M9BW D-B54 50 50 75 8.5 Auto Switch Mounting Position and Its Height Unit: mm Auto switch set value and its height 50 7.5 30.5 40 11.5 34.5 40 2 25 43.5 Auto switch D-B54 Symbol 63 7.5 30.5 47 11.5 34.5 47 2 25 50.5 40 11 23.5 34.5 15 27.5 34.5 5.5 18 38 32 3 30.5 30 7 34.5 30 0 25 33.5 Hs A B Hs A B Hs A B Hs B A 33 D-A93 D-M9B D-M9BW 24.5

CRQ2X MSQX MRQ Auto Switch Working Principle [Pressure is applied from the B port.] The auto switch B is turned ON by the magnet B in the state that the pressure is applied from the B port and the piston B moves to the left side. At this time, the auto switch A turns OFF . Magnet B Piston B A port B port Auto switch B Auto switch A [Pressure is applied from the A port.]

$9 $5 %4 CLG1 A' B' CL1 MLGC %2 Ball bushing bearing Front mounting flange View B-B' CNG #5 e #7 r #8 !

G A A (mm) Model A 110 120 171 B 38 48 66 C 1 1 2 D 30 40 55 Fn 34 70 Fc 17 26 41 G 40 39 63 H J P.C.D L1 6 x 4.4 6 x 6.6 L2 XMC-16 XMC-25 XMC-40 40 50 65 26 28 36 P.C.D 27 P.C.D 58.7 XMC-50 to 80/Angle type C L2 D Fd Fc L1 (KF flange) Fn C (K flange) (CF flange) H J K B G A A (mm) Model A 183 209 250 B 80 100 117 C 31 39 45.5 D 75 87 114 Fn 95 110 Fd 114 Fc 52 70 83 G 77 76.5 105 H

JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage.

(Same surface) Hs 22 B A D-A93 24.5 10.5 16.5 50 50 50 D-M9B D-M9BW D-B54 50 50 75 Auto Switch Mounting Position and Its Height Unit: mm 8.5 Auto switch set value and its height 63 7.5 30.5 47 11.5 34.5 47 2 25 50.5 Auto switch Symbol 40 11 23.5 34.5 15 27.5 34.5 5.5 18 38 50 7.5 30.5 40 11.5 34.5 40 2 25 43.5 A B Hs A B Hs A B Hs D-B54 D-A93 Hs B A 33 D-M9B D-M9BW D-B54 12 Note 1) The

Auto switch type Symbol Nil M9N (L) M9P (L) M9B (L) A90 (L) A93 (L) M9// Symbol Nil H0 Temperature range 5 to 60C 5 to 150C Without auto switch (without built-in magnet) Remarks Auto switch D-M9N (L) D-M9P (L) D-M9B (L) D-A90 (L) D-A93 (L) Solid state switch 6. No. of auto switches/Detecting position Symbol Nil A B C Quantity Without auto switch 2 pcs. 1 pc. 1 pc.

CDA2 B 50 200 X1184 B31J S With built-in special magnet Number of auto switches Cylinder stroke Description 2 pcs. 1 pc.

A90 A90V No Reed switch Solid state switch 2 wire 24V A93 A93V Grommet 100V 12V Yes 3 wire (NPN equiv.)

Magnet: Built-in, Mounting: Rod Flange, Bore: 16mm, Stroke: 175mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion: Air Cushion, Series: J2