Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9NW, Lead
Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes
),CF KF(NW) KF(NW),CF KF(NW) KF(NW),K(DN) ,CF KF(NW),K(D N) XYC KF(NW) KF(NW) KF(NW) KF(NW) K(DN) KF(NW) K(DN) Main material Body: SCS13(Stainless) Bellows: SUS316L, Main part: SUS304 and FKM (standard sealing material) Actuation pressure MPa (G) 0.3 to 0.6 0.4 to 0.6 Air consumption cm3 Note 3 At 0.5MPa 38 91 430 280 500 1000 Port size M5 Rc 1/8 XMC 0.36 (0.40) 0.62 1.40(1.76) 2.10 3.80
Magnet: Built-in Magnet, Series: J2K, Mounting: Double Clevis, Bore Size: 16mm, Stroke: 60mm, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: Pivot Bracket shipped w/Product, Not Assembled, Rod End Bracket: Double Knuckle Joint, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch
Magnet: Built-in Magnet, Series: J2Z, Mounting: Double Clevis, Bore Size: 16mm, Stroke: 60mm, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: Pivot Bracket shipped w/Product, Not Assembled, Rod End Bracket: Double Knuckle Joint, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: None, Lead
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: None, Lead
) KF (NW),CF KF(NW) KF (NW), K(DN),CF KF(NW), K (DN) Flange type XYD KF(NW) KF(NW) KF(NW) KF(NW), K(DN) KF(NW), K(DN) Main material Body: SCS13(Stainless) Bellows: SUS316L, Main part: SUS304 and FKM (standard sealing material) Note 2) Actuation pressure MPa (G) 0.4 to 0.7 Main pumping 46 200 360 660 1350 Air consumption cm3 for 0.5MPa Note 3) Initial pumping 2.5 12 15.5 30 42 Port size M5
Magnet: Built-in, Mounting: Double Clevis, Bore: 10mm, Stroke: 15mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9N, Lead Wire
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9N, Lead Wire
C D Side support B MY-SB 2-J 2-H C D A B J M4 x 0.7 M5 x 0.8 M6 x 1 M8 x 1.25 C 15 25 35 45 E 4.9 6.4 8 11.7 F 3 4 5 6 H 3.4 4.5 5.5 6.6 G 6.5 8 9.5 11 A 61 67 81 100 120 142 172 D 26 38 50 64 B 71.6 79.6 95 118 142 164 202 Applicable cylinder MY1W16 MY1W20 MY1W25 MY1W32 MY1W40 MY1W50 MY1W63 Model MY-S16A B MY-S20A B MY-S25A B MY-S32A B M10 x 1.5 55 14.8 8.5 9 14 80 MY-S40A B M12 x 1.75 70
C D Side support B MY-SB 2-J 2-H C D A B J M4 x 0.7 M5 x 0.8 M6 x 1 M8 x 1.25 C 15 25 35 45 E 4.9 6.4 8 11.7 F 3 4 5 6 H 3.4 4.5 5.5 6.6 G 6.5 8 9.5 11 A 61 67 81 100 120 142 172 D 26 38 50 64 B 71.6 79.6 95 118 142 164 202 Applicable cylinder MY1W16 MY1W20 MY1W25 MY1W32 MY1W40 MY1W50 MY1W63 Model MY-S16A B MY-S20A B MY-S25A B MY-S32A B M10 x 1.5 55 14.8 8.5 9 14 80 MY-S40A B M12 x 1.75 70
C D A B (mm) D-A9, D-A9V (mm) D-F9, D-F9V (mm) D-F9W, D-F9WV A B A B A B Bore size 16 25 32 Operating range Bore size 16 25 40 Operating range Bore size 16 25 40 Operating range 54 106 58 102 57 103 54 156 58 152 57 153 11 8.5 8.5 85 245 89 241 88 242 (mm) (mm) (mm) C D C D C D Bore size 16 25 32 Operating range Bore size 16 25 32 Operating range Bore size 16 25 32 Operating range 27 133
L E T U B E OD 6 A P P L I C A B L E T U B E OD 6 Courtesy of Steven Engineering, Inc. !