SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2D10-30Z-V-M9P-A"

V V V 100 V 93A Oilproof heavy-duty cord V V V M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V, 12 V 3-wire (PNP) M9PV M9P V V V v v 2-wire 12 V M9BV M9B V V V v v 3-wire (NPN) 5 V, 12 V S79 V V v v IC circuit 3-wire (PNP) S7P V V v v Solid state auto switch Grommet Yes For 20, 30, 40 Oilproof heavy-duty cord Relay, PLC 2-wire 12 V T79 V V v v Connector T79C V V V

Auto switch model Tightening torque D-M9l(V) D-M9lW(V) 0.10 to 0.15 Flat head watchmakers screwdriver (not an accessory) 5 to 6 Note) When tightening the auto switch mounting screw, use a watchmakers screwdriver with a handle diameter of about 5 to 6 mm. 724 Solid State Auto Switch Direct Mounting Type D-M9N(V)/D-M9P(V)/D-M9B(V) RoHS Refer to SMC website for the details of the products conforming

5 V, 12 V 100 V or less M9NV M9N 3-wire (NPN) IC circuit 5 V 12 V M9PV M9P 3-wire (PNP) M9BV M9B 12 V 2-wire F9NWV F9NW 3-wire (NPN) Diagnostic indication 2-color indication IC circuit 5 V 12 V Relay, PLC F9PWV F9PW 3-wire (PNP) Yes Grommet 24 V F9BWV F9BW Water resistant 2-color indication 2-wire 12 V F9BA Lead wire length symbols: 0.5 m Nil (Example) M9N 3 m L (Example) M9NL 5

D-H7BA D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-C7/C80 D-H7 D-H7W D-H7NF D-H7BA D-M9(V) D-M9W(V) D-M9A(V) D-A9(V) D-C7 D-C80 D-C73C D-C80C D-M9(V) D-M9W(V) D-M9A(V) D-C73C D-C80C D-B5 D-B64 D-B59W D-A9(V) Bore size (mm) Bore size (mm) B 24 (32) 24 (32) 25 (33) 27 (36) 32 (36) B 20 (28) 20 (28) 21 (29) 23 (32) 28 (40) A A 21.5 (29.5) B 20.5 (28.5) A B 15.5 (22.5) A B 17.5 (25.5) A B 19.5 (27.5

Auto Switch Proper Mounting Position (mm) A B C D Auto switch model D-M9; D-M9;V D-M9;W D-M9;WV D-M9;A D-M9;AV D-A9; D-A9;V D-M9; D-M9;V D-M9;W D-M9;WV D-M9;A D-M9;AV D-A9; D-A9;V D-M9; D-M9;V D-M9;W D-M9;WV D-M9;A D-M9;AV D-A9; D-A9;V D-M9; D-M9;V D-M9;W D-M9;WV D-M9;A D-M9;AV D-A9; D-A9;V K dimension (Switch rail height) Bore size 6 3 6 11 16 20 26 28 5.5 5.5 5.5 6 6 7.5 6.5 1.5 1.5 1.5

Weight Unit: g D-M9N(V) D-M9P(V) D-M9B(V) Auto switch model Caution 0.5 8 8 7 Lead wire length (m) 3 41 41 38 Precautions 5 68 68 63 Fix the switch with the existing screw installed on the switch body. The switch may be damaged if a screw other than the one supplied is used.

0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less Leakage current 100 A or less at 24 VDC 0.8 mA or less Indicator light Red LED illuminates when turned ON.

NCDQ8A(B)Z-(C)(M) (in) NCDQ8A(B)Z-T(M) (025st to 100st) (in) D-A9, D-A9V D-M9(V), D-M9W(V) D-A9, D-A9V D-M9(V), D-M9W(V) D-F9BAL D-F9BAL Bore size Bore size A B HS A B HS A B HS A B HS A B HS A B HS 056 075 106 150 200 250 300 400 056 075 106 150 200 250 0.24 0.14 0.33 0.31 0.2 0.35 0.37 0.49 0.04 0.08 0.12 0.12 0.2 0.28 0.34 0.53 0.71 0.81 0.96 1.18 1.45 1.6 1.94 2.44 0.39 0.3 0.49 0.47

(D-M9A(V)L can be used with a lead wire of 0.5 m and 3 m.) Note 3) 1 m (M): D-M9(V), M9W(V), M9A(V)L only.

Caution Weight Table Unit: g Operating Precautions D-M9N(V) D-M9B(V) D-M9P(V) Fix the switch with the existing screw installed on the switch body. The switch may be damaged if a screw other than the one supplied, is used.

For heavy stains, use a cloth lightly dampened with diluted neutral detergent, then wipe up any residue with a dry cloth. -8No.D-S-OMJ0004-G Model Indication and How to Order -9No.D-S-OMJ0004-G Summary of Product parts Summary of Product parts D-M9B(W/E)/D-M9N(W/E)/D-M9P(W/E) D-M9B(W/E)V/D-M9N(W/E)V/D-M9P(W/E)V -10No.D-S-OMJ0004-G Definition and terminology Term Meaning and definition 2 A

12 V 100 V Relay, PLC 2-wire 24 V 12 V Connector Diagnostic indication (2-color indication) A79W Grommet F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV F79 F7P J79 F79W F7PW J79W F7BA M9NV M9PV M9BV F9NWV F9PWV F9BWV M9N M9P M9B F9NW F9PW F9BW F9BA 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Grommet 2-wire 12 V Connector 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic

/D-M9P(V)/D-M9B(V) For details about certified products conforming to international standards, visit us at www.smcworld.com.

/D-M9P(V)/D-M9B(V) For details about certified products conforming to international standards, visit us at www.smcworld.com.

/D-M9P(V)/D-M9B(V) For details about certified products conforming to international standards, visit us at www.smcworld.com.

size (mm) Solid state switch D-P5DW A B HS (mm) D-P5DW Auto switch model 40, 50 A B Hs 9 7 4.5 7.5 44 50 Symbol Bore size (mm) 40 50 8 Series CQM Auto Switches/Proper Mounting Positions and Height for Stroke End Detection HS Reed switch D-A9 V Solid state switch D-F9 V D-F9 WV A B 12 HS A B 16, 20, 25 HS A B 32, 40, 50 (mm) D-F9 V, D-F9 WV D-A9 V Auto switch model Symbol A B Hs A B Hs 12

In-line D-M9N D-M9P D-M9B D-M9NA D-M9PA D-M9BA Electrical entry Special function Indicator light Wiring (Output) Applicable load Smbol A B C E F G 3-wire (NPN) 3-wire (PNP) 2-wire Relay, PLC IC circuit 24 V 5 V, 12 V Grommet Yes 12 V Yes 3-wire (NPN) 3-wire (PNP) 2-wire 24 V 5 V, 12 V Relay, PLC IC circuit Water resistance (2-color display) Grommet 12 V Option (For detail, refer to page

Solid State Auto Switch Direct Mounting Style D-M9N(V)/D-M9P(V)/D-M9B(V) RoHS Refer to SMC website for the details of the products conforming to the international standards.

V or less at 10 mA load current) Internal voltage drop 0.8 V or less 4 V or less Caution 100 A or less at 24 VDC Leakage current 0.8 mA or less at 24 VDC Operating Precautions Indicator light Red LED illuminates when turned ON.