Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths, Cylinder, Air, ROUND BODY CYLINDER, 0.114 lb

Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths, Cylinder, Air, ROUND BODY CYLINDER, 0.119 lb

Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths, CYL,DOUBLE_ACTING, ACTUATOR, CJ2 ROUND BODY CYLINDER, EE, 10MM CJ2 DBL-ACT AUTO-SW, 0.30864 lb

Magnet: D (Built-in Magnet), Mounting: D (Clevis), Type: N (Rubber Bumper), Bore: 20mm, Port Thread Type: TN [NPT ø20 to ø100 Rubber Bumper, ø32 to ø100 Air Cushion), Stroke: 25mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: N (Pivot Bracket not Assembled), Rod End Bracket: W (Double Knuckle Joint), Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical

Magnet: Built-in Magnet, Mounting: Clevis, Type: Rubber Bumper, Bore: 20mm, Port Thread Type: TN [NPT ø20 to ø100 Rubber Bumper, ø32 to ø100 Air Cushion), Stroke: 25mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: Pivot Bracket not Assembled, Rod End Bracket: Double Knuckle Joint, Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical, Lead Wire or Prewire Connection

Even if a proper plier (tool for installing a type C retaining ring) is used, it is likely to inflict damage to a human body or peripheral equipment, as a retaining ring may be flown out of the tip of a plier (tool for installing a type C retaining ring). Be cautious with the popping of a retaining ring.

Auto switch mounting Auto switch model C85 Series C75 Series Bore size [mm] 8 10 12 16 20 25 32 40 D-M9l(V) D-M9lW(V) D-A9l(V)*7 BJ6-008 (A set of a, b, c, d) BJ6-010 (A set of a, b, c, d) BJ6-012 (A set of a, b, c, d) BJ6-016 (A set of a, b, c, d) BM5-020 (A set of a, b, c, d) BM5-025 (A set of a, b, c, d) BM5-032 (A set of a, b, c, d) BM5-040 (A set of a, b, c, d) D-M9lA(V) BJ6-008S (A

Supply voltage Internal voltage drop of switch Minimum operating voltage of load > 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (Model A90, A90V). 3) Generally, the internal voltage drop will be greater with a 2wire solid state auto switch than with a reed switch.

Working principle A + A A Series CXS 6, 10, 15, 20, 25, 32 Reverse mounting Piston seal A A A R H R H 1. When the piston is retracting, air is exhausted through both A and A until piston seal H passes air passage A. 2. After piston seal H has passed air passage A, air is exhausted only through A.

C A C A B B B Auto switch mounting surface Auto switch mounting surface Auto switch mounting surface Auto switch model Port side Port/A/B/C side A/B/C side Port/A/B/C side BQ-2 BQ2-012 Two kinds of auto switch brackets are used as a set.

A B A B A B B A B A B A B B A B A B A 10 16 2 2 6 6 2.5 2.5 1.5 1.5 0.5 0.5 4.5 4.5 3 3 3.5 3.5 8.5 8.5 0.5 0.5 2.5 2.5 6.5 6.5 3 3 2 2 1 1 5 5 3.5 3.5 4 4 9 9 1 1 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.

Maintain a minimum cylinder separation of 40mm. (When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).

MM R1 MM CJP ND E1 NX1 A U1 R2 H Z E1 NX U1 LB A A NX A1 CJ2 A1 U1 LB JCM Part no.

Supply voltage Internal voltage drop of switch Minimum operating voltage of load > 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (Model A90, A90V). 3) Generally, the internal voltage drop will be greater with a 2wire solid state auto switch than with a reed switch.

Supply voltage > Internal voltage drop of switch Minimum operating voltage of load 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (Model DA90, A90V, A80(H)(C)). 3) Generally, the internal voltage drop will be greater with a 2wire solid state switch than with a reed switch.

Magnet: Built-in, Mounting: Double Clevis, Bore: 10mm, Stroke: 15mm, Head Cover: Perpendicular to Axis, Pivot Bracket: Pivot Bracket not Assembled, Rod End Bracket: Double Knuckle Joint, Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion

Magnet: Built-in, Mounting: Double Clevis, Bore: 10mm, Stroke: 75mm, Head Cover: Perpendicular to Axis, Pivot Bracket: Pivot Bracket not Assembled, Rod End Bracket: Double Knuckle Joint, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting

Magnet: Built-in, Mounting: Double Clevis, Bore: 10mm, Stroke: 150mm, Head Cover: Perpendicular to Axis, Pivot Bracket: Pivot Bracket not Assembled, Rod End Bracket: Double Knuckle Joint, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion:

Magnet: Built-in, Mounting: Double Clevis, Bore: 10mm, Stroke: 45mm, Head Cover: Perpendicular to Axis, Pivot Bracket: Pivot Bracket not Assembled, Rod End Bracket: Double Knuckle Joint, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting

Magnet: Built-in, Mounting: Double Clevis, Bore: 10mm, Stroke: 30mm, Head Cover: Perpendicular to Axis, Pivot Bracket: Pivot Bracket not Assembled, Rod End Bracket: Double Knuckle Joint, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Auto Switch Mounting: Band Mounting, Cushion: Rubber Bumper, Series: J2