Reed Auto Switch D-A90(V), D-A93(V), D-A96(V) Reed Auto Switch D-A90(V), D-A93(V), D-A96(V) (mm) Tightening Torque Stroke (mm) 20 45 25 45 25 51 31 Stroke (mm) 10 34.5 35.5 14.5 15.5 Model Model Tightening Torque of Auto Switch Mounting Screw (Nm) 25 50.5 30.5 30 59 39 10 35 15 35 15 15 40.5 20.5 A B A B A B A B A B C D Auto switch model Tightening torque MXP8 D-A9(V) D-M9(V) D-M9W(

(Extension) q w A B Air pressure supplied from B operates on surfaces e. (Retraction) A B e Improved workpiece mounting accuracy Positioning holes on the workpiece mounting surface allow easy alignment. Say goodbye to nonrotating guides!!

Auto switch (mm) Auto switch model D-A90 D-A93 D-M9N D-M9P D-M9B SMC CLS125 MODEL b a a b a b Bore size CLJ2 FREE LOCK CHECK 125 140 160 180 200 250 62 42 58 46 70.5 50.5 66.5 54.5 CLM2 Cylinder With$ Locking Mechanism 70.5 50.5 66.5 54.5 80.5 60.5 76.5 64.5 CLG1 86 66 82 70 102 82 98 86 CL1 Be sure to confirm operation after mounting.

MY1CW16/20 MY1MW16/20 MX B A MTS Reed Switch Solid State Switch D-A90(V), D-A93(V), D-A96(V) (mm) D-M9N(V), D-M9P(V), D-M9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) MY 16 20 Mounting position 16 20 Mounting position Mounting position 16 20 93 94 A A A 73 74 70 90 CY 107 106 B B B 87 86 90 110 6.5 7 8.5 6.5 Operating range Note) Operating range Note) Operating range Note) 11 7.5 MG CX MY1MW25/32

B D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Parallel electrical entry B A A D Reed Switch D-A90(V), D-A93(V), D-A96(V) Reed Switch D-A90(V), D-A93(V), D-A96(V) Set screw (included to auto switch) (mm) Stroke (mm) 20 45 25 51 31 Stroke (mm) 10 34.5 35.5

Material: Carbon steel 20 Series MU Auto Switch Proper Mounting Position (Detection at stroke end) and Mounting Height D-M9 D-M9W D-M9AL D-A9 D-M9V D-M9WV D-M9AVL D-A9V B B A A Hs Hv D-M9 D-M9W D-M9AL D-M9V D-M9WV D-M9AVL D-A9 D-M9V D-M9WV D-M9AVL Size A B A B Hs Hv A B A B Hs Hv 25 5 5 5 5 7.5 27.5 1 1 1 1 32 5 5 5 5 14.5 30 1 1 1 1 40 5.5 5.5 5.5 5.5 16.5 37 1.5 1.5 1.5 1.5 50 7

U B A CHA B A Related Products D-F7 D-F7W D-J79 D-J79W D-A7 D-A7H D-A8 D-A8H D-F7V D-F7WV D-F7BA D-F7BAV D-F7NT D-F79F D-J79C D-A73C D-A80C 32 to 100 DApprox. U B A Approx.

Mounting Heights for Stroke End Detection 20 & 25 Proper auto switch mounting positions (mm) B D-F9 D-F9V D-F9W D-F9WV D-A9 D-A9V D-A9 D-F9 D-F9W D-F9BAL Bore size (mm) SMC D-A90 B 15 16 A 12 13 B 19 20 A 11 12 B 18 19 A 8 9 SMC D-A90 20 25 A Approx.

MY1CW16/20 MY1MW16/20 B A Reed Switch Solid State Switch D-A90(V), D-A93(V), D-A96(V) (mm) D-M9N(V), D-M9P(V), D-M9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) 16 20 Mounting position Mounting position 16 20 A A B B Operating range Note) Operating range Note) Solid State Switch Reed Switch 24 Series MY1W Mounting of Auto Switch & Installation of Lead Wire Cover (50, 63) Caution Be sure to install

and Mounting Heights for Stroke End Detection 20 & 25 Proper auto switch mounting positions (mm) B D-F9 D-F9V D-F9W D-F9WV D-A9 D-A9V D-A9 D-F9 D-F9W D-F9BAL Bore size (mm) SMC D-A90 B 11 12 A 16 17 B 15 16 A 15 16 B 14 15 A 12 13 SMC D-A90 20 25 A Approx.

Nil M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 TF G 1/8 G 1/8 G 1/8 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 b C H B d M10 x 1.0 M20 x 1.5 M26 x 1.5 M32 x 2.0 H 4 8 8 10 B 14 26 32 41 C 16.2 30 37 47.3 Part No.

Reed switch Auto switch A90 Solid state M9B, M9N, F8B, F8N Size: 10, 20, 30, 50 11 Vacuum suction type Clean series 10 Size 20 30 50 11 MSQ B 10 A M9B 22 MSQ B 10 A M9B Number of auto switches A High precision type B Basic type Nil S n 2 pcs. 1 pc. n pcs.

C D A B (mm) D-A9, D-A9V (mm) D-F9, D-F9V (mm) D-F9W, D-F9WV A B A B A B Bore size 16 25 32 Operating range Bore size 16 25 40 Operating range Bore size 16 25 40 Operating range 54 106 58 102 57 103 54 156 58 152 57 153 11 8.5 8.5 85 245 89 241 88 242 (mm) (mm) (mm) C D C D C D Bore size 16 25 32 Operating range Bore size 16 25 32 Operating range Bore size 16 25 32 Operating range 27 133

[ ]: Value of the D-M9A ( ): Value of the D-A90/A93 D-M9V D-M9WV D-M9AV D-A9V A 20 (22) W B ( ): Value of the D-M9AV/A9V (mm) D-A9, D-A9V D-M9W, D-M9 D-M9WV, D-M9V A 16.5 15.0 22.0 30.0 D-M9A A 16.5 15.0 22.0 30.0 D-M9AV A 16.5 15.0 22.0 30.0 Bore size (mm) 6 10 16 20 B 2.5 7.5 8.0 10.5 B 2.5 7.5 8.0 10.5 W 5.5 0 0 2.5 W 7.5 2.0 2.0 0.5 B 2.5 7.5 8.0 10.5 B 2.5 7.5 8.0 10.5 A 16.5 15.0 22.0

There are two types of alarm reset: alarm reset manually (a) and an alarm reset externally (b) by an external signal.

Nil S n Reed switch Auto switch A90 Solid state M9B, M9N, F8B, F8N Size: 10, 20, 30, 50 11 Vacuum suction type Clean series 10 Size 20 30 50 11 MSQ B 10 A M9B 22 MSQ B 10 A M9B Number of auto switches A High precision type B Basic type 2 pcs. 1 pc. n pcs.

Magnet: D (Built-in Magnet), Series: J2K, Mounting: B (Basic), Bore Size: 10mm, Stroke: 15mm, Head Cover Port Location: R (Axial), Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)

Magnet: Built-in, Mounting: Single Foot, Bore: 16mm, Stroke: 15mm, Head Cover: Axial, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion: Rubber Bumper, Series: J2