SMC Corporation of America
Elite Part Number Search
Search Results "CDBX2N15-75-A73"

Cylinder: Auto Switch/Housing Mount, Model: Non-lube, Bore Size: 15mm, Port Thread: Rc (M ø10, ø15), Stroke: 50mm, Cushion: 2 Adjuster Bolts, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Cylinder: Auto Switch/Housing Mount, Model: Non-lube, Bore Size: 15mm, Port Thread: Rc (M ø10, ø15), Stroke: 50mm, Cushion: Shock Absorbers, 2 pcs, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Cylinder: Auto Switch/Housing Mount, Model: Non-lube, Bore Size: 15mm, Port Thread: Rc (M ø10, ø15), Stroke: 75mm, Cushion: Absorber, 1 pc, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Cylinder: Auto Switch/Housing Mount, Model: Non-lube, Bore Size: 15mm, Port Thread: Rc (M ø10, ø15), Stroke: 200mm, Cushion: 2 Adjuster Bolts, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Cylinder: Auto Switch/Housing Mount, Model: Non-lube, Bore Size: 15mm, Port Thread: Rc (M ø10, ø15), Stroke: 100mm, Cushion: 2 Adjuster Bolts, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

type: M Screw, Auto Switches: A73, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Shaft Bearing: Slide bearing, Custom-made Specifications: None, Mount Type: Housing mounting, Type: Non-lube

Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: With adjusting bolt (2 pcs.), Operating Pressure(MPa): 0.15 to 1.0, Specification: With magnet, Port thread

type: M Screw, Auto Switches: A73, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Shaft Bearing: Slide bearing, Custom-made Specifications: None, Mount Type: Housing mounting, Type: Non-lube

Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: With adjusting bolt (2 pcs.), Operating Pressure(MPa): 0.15 to 1.0, Specification: With magnet, Port thread

Bore size/Stroke (mm) 10 25, 50, 75, 100 Cushion (Option) 15 25, 50, 75, 100, 125, 150, 175, 200 With adjusting bolt (2 pcs.) Nil 25 25, 50, 75, 100, 125, 150, 175, 200 B With shock absorber (2 pcs.) For 15 and 25, strokes up to 300 are available as made-to-order. (-XB11) BS With shock absorber (1 pc.)

Foot type Flange type Knuckle joint Clevis type Flexible mounting: Possible to mount on all surfaces except for the one with ports Bottom mounting type Side mounting type Axial surface mounting Series Variations Standard stroke (mm) Locking direction Bore size (mm) Series 5 10 15 20 25 30 35 40 45 50 75 100 125 150 175 200 250 300 25 Extension lock 32 MLU 40 Retraction lock 50 Features 2

Auto switches are not mounted, but rather packaged together with the cylinder for shipment. 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 12, 16 20 25 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 32, 40 Manufacturing intermediate strokes Intermediate strokes can be manufactured in 1mm increments by installing spacers in a standard stroke cylinder.

Information End Lock Cylinder Series CBJ2 / 16 Cylinder stroke (mm) 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate strokes are available in 1 mm increments without stroke adjustment with a spacer. For types with auto switch, refer to Minimum Strokes for Auto Switch Mounting on page 2.

How to Order . 60 61 62 63 64 66 67 69 69 70 71 72 74 75 76 76 77 78 78 80 81 82 84 88 89 90 91 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 92 93 94 94 95 95 95 95 96 96 96 96 96 97 97 98 98 99 99 99 100 100 102 103 103 104 106 106 107 109 111 111 Caution .

Piston rod Standard stroke (mm) Locking direction Bore size (mm) Series 5 10 15 20 25 30 35 40 45 50 75 100 125 150 175 200 250 300 LOCK LOCK Load direction Fulcrum FREE 25 Extension lock 32 MLU Pivot 40 Retraction lock Clearance 50 9-13-2 9-13-3 3 Series MLU Specific Product Precautions 1 Be sure to read before handling. Selection Selection Warning Allowable Load Weight 1.

Cylinder: DB (Auto Switch/Housing Mount), Model: N (Non-lube), Bore Size: 15mm, Port Thread: Rc (M ø10, ø15), Stroke: 75mm

Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: With adjusting bolt (2 pcs.), Operating Pressure(MPa): 0.15 to 1.0, Specification: With magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: With adjusting bolt (2 pcs.), Operating Pressure(MPa): 0.15 to 1.0, Specification: With magnet, Port thread

Weight (g) Auto switch model D-F6N D-F6P D-F6B 20 0.5 m (Nil) 19 3 m (L) Lead wire length 53 50 5 m (Z) 80 75 Dimensions (mm) D-F6 D-F6B 8.5 (22) 3.2 Indicator light (24) 16 Most sensitive position 7 2.7 10.6 7 29 D-F6N/F6P DD(22) 3.2 Most sensitive position 7 1609 Auto Switches Precautions 1 Be sure to read this before handling.

Applicable model: D-A73, A73H, A73C, C73, C73C, E73A, Z73 D-R73, R73C, 97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed.